Determination of the mass attenuation coefficients for X-ray fluorescence measurements correction by the Rayleigh to Compton scattering ratio

被引:13
|
作者
Conti, C. C. [1 ,2 ]
Anjos, M. J. [2 ]
Salgado, C. M. [3 ]
机构
[1] Inst Radioprotecao & Dosimetria IRD CNEN, BR-22783127 Rio De Janeiro, Brazil
[2] State Univ Rio de Janeiro UERJ, Inst Phys, Rio De Janeiro, Brazil
[3] Nucl Engn Inst IEN CNEN, Rio De Janeiro, Brazil
关键词
MCNP5; X-ray; Fluorescence; Mass attenuation coefficient; EFFECTIVE ATOMIC-NUMBER; HPGE DETECTOR; RADIATION; COHERENT; MCNP5;
D O I
10.1016/j.nimb.2014.06.004
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
X-ray fluorescence technique plays an important role in nondestructive analysis nowadays. The development of equipment, including portable ones, enables a wide assortment of possibilities for analysis of stable elements, even in trace concentrations. Nevertheless, despite of the advantages, one important drawback is radiation self-attenuation in the sample being measured, which needs to be considered in the calculation for the proper determination of elemental concentration. The mass attenuation coefficient can be determined by transmission measurement, but, in this case, the sample must be in slab shape geometry and demands two different setups and measurements. The Rayleigh to Compton scattering ratio, determined from the X-ray fluorescence spectrum, provides a link to the mass attenuation coefficient by means of a polynomial type equation. This work presents a way to construct a Rayleigh to Compton scattering ratio versus mass attenuation coefficient curve by using the MCNP5 Monte Carlo computer code. The comparison between the calculated and literature values of the mass attenuation coefficient for some known samples showed to be within 15%. This calculation procedure is available on-line at www.macx.net.br. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:61 / 65
页数:5
相关论文
共 50 条
  • [1] Improved Rayleigh to Compton scattering ratio curves for mass attenuation coefficients determination for X-ray fluorescence analysis
    Conti, C. C.
    Anjos, M. J.
    Salgado, C. M.
    X-RAY SPECTROMETRY, 2017, 46 (06) : 522 - 528
  • [2] Absolute determination of the effect of scattering and fluorescence on x-ray attenuation measurements
    Tran, CQ
    de Jonge, MD
    Barnea, Z
    Chantler, CT
    JOURNAL OF PHYSICS B-ATOMIC MOLECULAR AND OPTICAL PHYSICS, 2004, 37 (15) : 3163 - 3176
  • [3] DETERMINATION OF MASS ABSORPTION COEFFICIENTS BY X-RAY FLUORESCENCE
    EBEL, H
    ZEITSCHRIFT FUR METALLKUNDE, 1970, 61 (01): : 62 - &
  • [4] Determination of X-ray mass attenuation coefficients using HPGe detector
    Sharanabasappa
    Kerur, B. R.
    Anilkumar, S.
    Hanumaiah, B.
    APPLIED RADIATION AND ISOTOPES, 2010, 68 (01) : 76 - 83
  • [5] RAYLEIGH AND COMPTON-SCATTERING CONTRIBUTIONS TO X-RAY-FLUORESCENCE INTENSITY
    FERNANDEZ, JE
    X-RAY SPECTROMETRY, 1992, 21 (02) : 57 - 68
  • [6] Suitability of the Compton-to-Rayleigh ratio in X-ray fluorescence spectroscopy: hydroxyapatite-based materials characterization
    Pessanha, Sofia
    Silva, Sara
    Martins, Luis
    Santos, Jose Paulo
    Silveira, Joao M.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2019, 34 (05) : 854 - 859
  • [7] Study of Rayleigh to Compton scattering ratio for pharmaceutical ingredients at 8 keV to 32 keV X-ray energy
    Manjunath, A.
    Kerur, B. R.
    MATERIALS TODAY-PROCEEDINGS, 2016, 3 (10) : 4134 - 4139
  • [8] Measurement of mass attenuation coefficients of biological materials by energy dispersive X-ray fluorescence spectrometry
    Ekinci, N.
    Astam, N.
    RADIATION MEASUREMENTS, 2007, 42 (03) : 428 - 430
  • [9] Influence of mass attenuation coefficients on the accuracy of calculations of X-ray fluorescence intensities of petrogenic elements
    Borkhodoev, VY
    JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 53 (06) : 500 - 505
  • [10] Reconstruction of mammography x-ray spectrum by using Rayleigh and Compton scattering corrections
    Kawaguchi, Souichiro
    Yamaguchi, Yoshiki
    Arimura, Hidetaka
    Morishita, Junji
    Ohki, Masafumi
    Uno, Yoshinori
    Ideguchi, Tadamitsu
    Higashida, Yoshiharu
    Toyofuku, Fukai
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 2 - DIAGNOSTIC IMAGING, 2009, 25 : 231 - 233