Sources of Error in Toric Intraocular Lens Power Calculation

被引:32
|
作者
Hirnschall, Nino [1 ]
Findl, Oliver [1 ,3 ]
Bayer, Natascha [1 ]
Leisser, Christoph [1 ]
Norrby, Sverker
Zimper, Eva [1 ]
Hoffmann, Peter [2 ]
机构
[1] Hanusch Hosp, Vienna Inst Res Ocular Surg, A Karl Landsteiner Inst, Vienna, Austria
[2] Eye & Laser Clin, Castrop Rauxel, Germany
[3] Moorfields Eye Hosp NHS Fdn Trust, London, England
关键词
OPTICAL COHERENCE TOMOGRAPHY; RESIDUAL REFRACTIVE ASTIGMATISM; POSTERIOR CORNEAL SURFACE; CATARACT-SURGERY; VECTOR ANALYSIS; BIOMETER REPEATABILITY; ROTATIONAL STABILITY; CLINICAL-OUTCOMES; TEAR FILM; IMPLANTATION;
D O I
10.3928/1081597X-20200729-03
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate the influencing factors on remaining astigmatism after implanting a toric intraocular tens (IOL) during cataract surgery. METHODS: This retrospective study included parameters that were considered to have an influence on toric IOL power calculation. Therefore, data from the literature and the authors' own data were used. This included axial eye length, anterior chamber depth, central corneal thickness, corneal radii (anterior and posterior), diurnal changes of the cornea, interdevice differences, rotational misalignment of the IOL, tilt and decentration of the IOL, pupil size, angle kappa, and surgically induced astigmatism. Ray-tracing and Gaussian error propagation analysis was performed to quantify the sources of error. RESULTS: In total, 4,949 eyes (4,365 eyes of 42 studies and 584 eyes of retrospectively analyzed study data) were included in the study and the difference vector between aimed and calculated remaining astigmatism was 0.81 diopters (D). The main source of error was the preoperative measurement of the cornea (27%), followed by IOL misalignment (14.4%) and IOL tilt (11.3%). Other factors, such as angle kappa (10.9%), pupil size (8.1%), surgically induced astigmatism (7.8%), anterior chamber depth (7.5%), axial eye length (7.5%), and decentration (5.6%), also contributed to the refractive astigmatic error. CONCLUSIONS: The main source of error in toric IOL power calculation is the preoperative corneal measurement followed by IOL misalignment and tilt.
引用
收藏
页码:646 / 652
页数:7
相关论文
共 50 条
  • [1] Sources of error in intraocular lens power calculation
    Norrby, Sverker
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (03): : 368 - 376
  • [2] SOURCES OF ERROR IN INTRAOCULAR-LENS POWER CALCULATION
    OLSEN, T
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1992, 18 (02): : 125 - 129
  • [3] A New Slant on Toric Intraocular Lens Power Calculation
    Savini, Giacomo
    Hoffer, Kenneth J.
    Ducoli, Pietro
    JOURNAL OF REFRACTIVE SURGERY, 2013, 29 (05) : 348 - 354
  • [4] Toric intraocular lens power calculation in cataract patients with keratoconus
    Ton, Yokrat
    Barrett, Graham D.
    Kleinmann, Guy
    Levy, Adi
    Assia, Ehud I.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2021, 47 (11): : 1389 - 1397
  • [5] Accuracy of Ten Intraocular Lens Formulas in Spherical Equivalent of Toric Intraocular Lens Power Calculation
    Jingyi Shi
    Zehui Zhu
    Bin Hu
    Shuyi Qian
    Yalan Wang
    Pingjun Chang
    Yun-e Zhao
    Ophthalmology and Therapy, 2024, 13 : 1321 - 1342
  • [6] Accuracy of Ten Intraocular Lens Formulas in Spherical Equivalent of Toric Intraocular Lens Power Calculation
    Shi, Jingyi
    Zhu, Zehui
    Hu, Bin
    Qian, Shuyi
    Wang, Yalan
    Chang, Pingjun
    Zhao, Yun-e
    OPHTHALMOLOGY AND THERAPY, 2024, 13 (05) : 1321 - 1342
  • [7] Intraocular lens constant optimization in toric intraocular lens calculation using keratometry and total corneal power
    Liang, Jianheng
    Liu, Hui
    Zhou, Suowang
    Zhou, Lijing
    Qian, Zhuyun
    Jiang, Lihong
    Chen, Xu
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2023, 33 (01) : 230 - 238
  • [8] Comparison of Axis Determination With Different Toric Intraocular Lens Power Calculation Methods
    Roeggla, Veronika
    Schartmueller, Daniel
    Schwarzenbacher, Luca
    Al Chbib, Rima
    Leydolt, Christina
    Menapace, Rupert
    JOURNAL OF REFRACTIVE SURGERY, 2021, 37 (09) : 642 - 647
  • [9] Comparison of toric intraocular lens alignment error with different toric markers
    Lipsky, Lior
    Barrett, Graham
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (11): : 1597 - 1601
  • [10] Calculation of Toric Intraocular Lens Power with the Barrett Calculator and Data from Three Keratometers
    Dong, Jing
    Zhang, Yaqin
    Wang, Xiaogang
    JOURNAL OF TROPICAL MEDICINE, 2021, 2021