Dual- and Multi-Energy CT: Principles, Technical Approaches, and Clinical Applications

被引:1168
|
作者
McCollough, Cynthia H. [1 ]
Leng, Shuai [1 ]
Yu, Lifeng [1 ]
Fletcher, Joel G. [1 ]
机构
[1] Mayo Clin, Dept Radiol, Rochester, MN 55905 USA
基金
美国国家卫生研究院;
关键词
ENERGY-COMPUTED-TOMOGRAPHY; VIRTUAL NONENHANCED IMAGES; ACID RENAL STONES; X-RAY-DETECTORS; LUNG PERFUSION; URIC-ACID; BONE REMOVAL; MULTIDETECTOR CT; NOISE-REDUCTION; AUTOMATIC BONE;
D O I
10.1148/radiol.2015142631
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In x-ray computed tomography (CT), materials having different elemental compositions can be represented by identical pixel values on a CT image (ie, CT numbers), depending on the mass density of the material. Thus, the differentiation and classification of different tissue types and contrast agents can be extremely challenging. In dual-energy CT, an additional attenuation measurement is obtained with a second x-ray spectrum (ie, a second "energy"), allowing the differentiation of multiple materials. Alternatively, this allows quantification of the mass density of two or three materials in a mixture with known elemental composition. Recent advances in the use of energy-resolving, photon-counting detectors for CT imaging suggest the ability to acquire data in multiple energy bins, which is expected to further improve the signal-to-noise ratio for material-specific imaging. In this review, the underlying motivation and physical principles of dualor multi-energy CT are reviewed and each of the current technical approaches is described. In addition, current and evolving clinical applications are introduced. (C)RSNA, 2015
引用
收藏
页码:637 / 653
页数:17
相关论文
共 50 条
  • [41] Dual Energy CT: Physics Principles
    Pelc, N.
    MEDICAL PHYSICS, 2008, 35 (06) : 2861 - +
  • [42] Dual-Source Multi-Energy CT with Triple or Quadruple X-ray Beams
    Yu, Lifeng
    Li, Zhoubo
    Leng, Shuai
    McCollough, Cynthia H.
    MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
  • [43] Cardiac Dual-Energy CT Applications and Clinical Impact
    Albrecht M.H.
    De Cecco C.N.
    Nance J.W., Jr.
    Varga-Szemes A.
    De Santis D.
    Eid M.
    Tesche C.
    Apfaltrer G.
    von Knebel Doeberitz P.L.
    Jacobs B.
    Vogl T.J.
    Joseph Schoepf U.
    Current Radiology Reports, 5 (9)
  • [44] Applications of dual energy CT in clinical practice: A pictorial essay
    Sanghavi, Parang S.
    Jankharia, Bhavin G.
    INDIAN JOURNAL OF RADIOLOGY AND IMAGING, 2019, 29 (03): : 289 - 298
  • [45] Adaptive Multi-Energy Local Mean Filtering for Photon-Counting-Detector Based Multi-Energy CT
    Tao, S.
    Rajendran, K.
    Ferrero, A.
    Zhou, W.
    McCollough, C.
    Leng, S.
    MEDICAL PHYSICS, 2018, 45 (06) : E672 - E672
  • [46] Dual-Energy CT: Dual-KV Techniques and Clinical Applications
    McCollough, C.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [47] Multi-Energy CT: Current Status and Recent Innovations
    Pelc, N.
    McCollough, C.
    Yu, L.
    Schmidt, T.
    MEDICAL PHYSICS, 2014, 41 (06) : 512 - 513
  • [48] Multi-Energy CT Reconstruction with Sparse Segmental Scan
    Luo, N.
    Zhong, A.
    Li, B.
    Ma, J.
    Xu, Y.
    Zhou, L.
    MEDICAL PHYSICS, 2018, 45 (06) : E674 - E674
  • [49] Novel Contrast Agents for Multi-Energy CT Imaging
    Sahani, D.
    Yu, L.
    Taguchi, K.
    Cormode, D.
    MEDICAL PHYSICS, 2018, 45 (06) : E648 - E648
  • [50] JOINT RECONSTRUCTION IN LOW DOSE MULTI-ENERGY CT
    Toivanen, Jussi
    Meaney, Alexander
    Siltanen, Samuli
    Kolehmainen, Ville
    INVERSE PROBLEMS AND IMAGING, 2020, 14 (04) : 607 - 629