High-Speed Shape and Transient Response Measurements of Tympanic Membrane

被引:1
|
作者
Razavi, Payam [1 ,2 ]
Tang, Haimi [1 ,2 ]
Maftoon, Nima [3 ,4 ]
Rosowski, John J. [3 ,4 ]
Furlong, Cosme [1 ,2 ,3 ,4 ]
Cheng, Jeffrey Tao [3 ,4 ]
机构
[1] Worcester Polytech Inst, Ctr Holog Studies & Laser MicromechaTron CHSLT, Worcester, MA 01609 USA
[2] Worcester Polytech Inst, Mech Engn Dept, Worcester, MA 01609 USA
[3] Massachusetts Eye & Ear MEE, Eaton Peabody Lab, Boston, MA USA
[4] Harvard Med Sch, Dept Otol & Laryngol, Boston, MA 02115 USA
关键词
Holographic interferometry; Multiple wavelength; Shape measurement; Transient response; Tympanic membrane; HOLOGRAPHY; MOTIONS;
D O I
10.1007/978-3-319-97481-1_33
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
We are developing a High-speed Digital Holographic (HDH) system to measure acoustically induced transient displacements of live mammalian Tympanic Membranes (TM) for research and clinical applications. To date, the HDH can measure one-dimensional displacements along a single 1-D sensitivity vector. However, because of the TM's tent-like shape and angled orientation inside the ear canal, 1-D measurements need to be combined with measurements of the shape and orientation of the TM to determine the true surface normal (out-of-plane) displacements. Furthermore, TM shape also provides invaluable information for better diagnostic and modelling of the TM. To introduce shape measurements capabilities into our HDH, a tunable laser (line width <300 kHz, 770.2-790 nm, <8 nm/s) is incorporated in tandem with the single frequency (line width <100 MHz, 532.3 nm) laser used for displacement measurements in a manner that provides a common sensitivity vector for the two measurements. Interferograms gathered with continuous high-speed optical phase sampling and wavelength tuning allow the reconstruction of the TM shape with <50 mu m measuring resolution and <120 mu m repeatability. With our modified HDH, shape measurements immediately follow transient displacement measurements (>67 kHz temporal and <15 nm displacement resolutions) in response to broadband acoustic click excitations (50 mu s duration). Both shape and displacement can be measured in less than 150 ms, which avoids slow disturbances introduced by breathing and heartbeat, with the promise of future measurements in vivo. Representative shape and displacement measurements capabilities are demonstrated on cadaveric human temporal bones.
引用
收藏
页码:243 / 250
页数:8
相关论文
共 50 条
  • [21] HIGH-SPEED PHOTOGRAPHY OF TRANSIENT EXCITATION
    LEIGHTON, TG
    WALTON, AJ
    FIELD, JE
    ULTRASONICS, 1989, 27 (06) : 370 - 373
  • [22] HIGH-SPEED PICKUP OF TRANSIENT IMAGES
    BOUCHARLAT, G
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1985, 491 : 716 - 722
  • [23] HIGH-SPEED TRANSIENT DYNAMIC ANALYSIS
    LINDSAY, JC
    MASKET, AV
    PHYSICAL REVIEW, 1954, 95 (02): : 665 - 665
  • [24] High-speed shape recovery of SMA
    Tani, J
    Qiu, J
    Urushiyama, Y
    IMPACT ENGINEERING AND APPLICATION, VOLS I AND II, 2001, : 691 - 698
  • [25] Transient Response of ESD Protection Devices for a High-Speed I/O Interface
    Zhou, Jianchi
    Xu, Yang
    Bub, Sergej
    Holland, Steffen
    Meiguni, Javad Soleiman
    Pommerenke, David
    Beetner, Daryl G.
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2022, 64 (04) : 907 - 914
  • [26] Accurate, High-Speed Simulation of Transient Response and Frequency Characteristics of Switching Converters
    Sugimoto, Shoko
    Suzuki, Masahiro
    Sugimoto, Yasuhiro
    PROCEEDINGS OF THE 2010 IEEE ASIA PACIFIC CONFERENCE ON CIRCUIT AND SYSTEM (APCCAS), 2010, : 464 - 467
  • [27] HIGH-SPEED, MEDIUM VOLTAGE PULSE-AMPLIFIER FOR DIODE REVERSE TRANSIENT MEASUREMENTS
    CHUDOBIAK, MJ
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (11): : 5352 - 5354
  • [28] Accurate transient response model for automatic synthesis of high-speed operational amplifiers
    Azzolini, Cristiano
    Milanesi, Paolo
    Boni, Andrea
    2006 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS, VOLS 1-11, PROCEEDINGS, 2006, : 5716 - +
  • [29] Transient contact heat transfer measurements based on high-speed IR-thermography
    Burghold, E. M.
    Frekers, Y.
    Kneer, R.
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2017, 115 : 169 - 175
  • [30] Measurements of high-speed MSM photodetectors
    Paszkiewicz, B
    Tomaska, M
    Krnac, M
    Kovac, J
    Szreter, M
    Boratynski, B
    MIKON-2000, VOLS 1 & 2, PROCEEDINGS, 2000, : 711 - 714