High-Speed Shape and Transient Response Measurements of Tympanic Membrane

被引:1
|
作者
Razavi, Payam [1 ,2 ]
Tang, Haimi [1 ,2 ]
Maftoon, Nima [3 ,4 ]
Rosowski, John J. [3 ,4 ]
Furlong, Cosme [1 ,2 ,3 ,4 ]
Cheng, Jeffrey Tao [3 ,4 ]
机构
[1] Worcester Polytech Inst, Ctr Holog Studies & Laser MicromechaTron CHSLT, Worcester, MA 01609 USA
[2] Worcester Polytech Inst, Mech Engn Dept, Worcester, MA 01609 USA
[3] Massachusetts Eye & Ear MEE, Eaton Peabody Lab, Boston, MA USA
[4] Harvard Med Sch, Dept Otol & Laryngol, Boston, MA 02115 USA
关键词
Holographic interferometry; Multiple wavelength; Shape measurement; Transient response; Tympanic membrane; HOLOGRAPHY; MOTIONS;
D O I
10.1007/978-3-319-97481-1_33
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
We are developing a High-speed Digital Holographic (HDH) system to measure acoustically induced transient displacements of live mammalian Tympanic Membranes (TM) for research and clinical applications. To date, the HDH can measure one-dimensional displacements along a single 1-D sensitivity vector. However, because of the TM's tent-like shape and angled orientation inside the ear canal, 1-D measurements need to be combined with measurements of the shape and orientation of the TM to determine the true surface normal (out-of-plane) displacements. Furthermore, TM shape also provides invaluable information for better diagnostic and modelling of the TM. To introduce shape measurements capabilities into our HDH, a tunable laser (line width <300 kHz, 770.2-790 nm, <8 nm/s) is incorporated in tandem with the single frequency (line width <100 MHz, 532.3 nm) laser used for displacement measurements in a manner that provides a common sensitivity vector for the two measurements. Interferograms gathered with continuous high-speed optical phase sampling and wavelength tuning allow the reconstruction of the TM shape with <50 mu m measuring resolution and <120 mu m repeatability. With our modified HDH, shape measurements immediately follow transient displacement measurements (>67 kHz temporal and <15 nm displacement resolutions) in response to broadband acoustic click excitations (50 mu s duration). Both shape and displacement can be measured in less than 150 ms, which avoids slow disturbances introduced by breathing and heartbeat, with the promise of future measurements in vivo. Representative shape and displacement measurements capabilities are demonstrated on cadaveric human temporal bones.
引用
收藏
页码:243 / 250
页数:8
相关论文
共 50 条
  • [1] High-Speed Digital Holography for Transient Response of the Human Tympanic Membrane
    Dobrev, I.
    Furlong, C.
    Rosowski, J. J.
    Cheng, J. T.
    ADVANCEMENT OF OPTICAL METHODS IN EXPERIMENTAL MECHANICS, VOL 3, 2015, : 337 - 342
  • [2] Combined high-speed holographic shape and full-field displacement measurements of tympanic membrane
    Razavi, Payam
    Tang, Haimi
    Rosowski, John J.
    Furlong, Cosme
    Cheng, Jeffrey T.
    JOURNAL OF BIOMEDICAL OPTICS, 2019, 24 (03)
  • [3] Analyses of the Tympanic Membrane Impulse Response Measured with High-Speed Holography
    Tang, H.
    Psota, P.
    Rosowski, J. J.
    Furlong, C.
    Cheng, J. T.
    HEARING RESEARCH, 2021, 410
  • [4] High-Speed Holographic Shape and Full-Field Displacement Measurements of the Tympanic Membrane in Normal and Experimentally Simulated Pathological Ears
    Tang, Haimi
    Razavi, Payam
    Pooladvand, Koohyar
    Psota, Pavel
    Maftoon, Nima
    Rosowski, John J.
    Furlong, Cosme
    Cheng, Jeffrey T.
    APPLIED SCIENCES-BASEL, 2019, 9 (14):
  • [5] High-speed holographic system for full-field transient vibrometry of the human tympanic membrane
    Dobrev, I.
    Harrington, E. J.
    Cheng, T.
    Furlong, C.
    Rosowski, J. J.
    INTERFEROMETRY XVII: ADVANCED APPLICATIONS, 2014, 9204
  • [6] HIGH-SPEED SCHLIEREN IMAGING OF SHOCK WAVES FOR THE STUDY OF TYMPANIC MEMBRANE'S RESPONSE
    Luiz, Jonathan Oliveira
    Alipanahi, Anahita
    Cheng, Jeffrey Tao
    Rosowski, John J.
    Furlong-Vazquez, Cosme
    PROCEEDINGS OF ASME 2023 INTERNATIONAL DESIGN ENGINEERING TECHNICAL CONFERENCES AND COMPUTERS AND INFORMATION IN ENGINEERING CONFERENCE, IDETC-CIE2023, VOL 12, 2023,
  • [7] Full-field transient vibrometry of the human tympanic membrane by local phase correlation and high-speed holography
    Dobrev, Ivo
    Furlong, Cosme
    Cheng, Jeffrey T.
    Rosowski, John J.
    JOURNAL OF BIOMEDICAL OPTICS, 2014, 19 (09)
  • [8] High-speed video observation of tympanic membrane rupture in guinea pigs
    Koike, T
    Wada, H
    Ito, F
    Takayama, K
    Kobayashi, T
    JSME INTERNATIONAL JOURNAL SERIES C-MECHANICAL SYSTEMS MACHINE ELEMENTS AND MANUFACTURING, 2003, 46 (04) : 1434 - 1440
  • [9] EXTENDING TRANSDUCER TRANSIENT RESPONSE BY ELECTRONIC COMPENSATION FOR HIGH-SPEED PHYSICAL MEASUREMENTS
    LIU, FF
    BERWIN, TW
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1958, 29 (01): : 14 - 22
  • [10] Numerical model characterization of the sound transmission mechanism in the tympanic membrane from a high-speed digital holographic experiment in transient regime
    Garcia-Manrique, J.
    Furlong, Cosme
    Gonzalez-Herrera, A.
    Cheng, Jeffrey T.
    ACTA BIOMATERIALIA, 2023, 159 : 63 - 73