Study of the double-pulse setup with an orthogonal beam geometry for laser-induced breakdown spectroscopy

被引:86
|
作者
Gautier, C
Fichet, P
Menut, D
Lacour, JL
L'Hermite, D
Dubessy, J
机构
[1] CEA Saclay, Nucl Energy Div, LRSI, F-91191 Gif Sur Yvette, France
[2] Univ Nancy 1, CREGU G2R, UMR 7566, F-54501 Vandoeuvre Les Nancy, France
关键词
laser-induced breakdown spectroscopy (LIBS); double-pulse; aluminum; Echelle spectrometer;
D O I
10.1016/j.sab.2004.05.002
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
single- and double-pulse laser-induced breakdown spectroscopy (LIBS) was applied on aluminum samples at atmospheric pressure in air. In the case of the double-pulse scheme, experiments were carried out with an ablation laser emitting at 532 nm and a reheating laser emitting at 1064 nm in an orthogonal beam geometry. With the use of a 1-m focal length monochromator and an echelle spectrometer both equipped with an intensified charge coupled device (ICCD), the studies on the effect of the delay between the two laser pulses displayed optimum enhancements of line emissions only at 200 ns in the reheating scheme developed here. The experimental parameters, like the signal acquisition delay, were largely studied. The line intensity enhancements were also investigated in dependence on physical parameters, such as the excitation energy levels of the lines observed. Moreover, the relative importance of ionic and neutral lines in the emission spectra was precisely characterized. From the different investigations, the behaviors of the line emissions towards the double-pulse technique were related to their excitation energy levels. A correlation between the increases in intensity and the excitation energy levels of the line emissions was highlighted. As a result, the reheating scheme showed improvements of sensitivity for elements emitting ionic lines compared with the corresponding single-pulse experiments. (C) 2004 Elsevier B.V All rights reserved.
引用
收藏
页码:975 / 986
页数:12
相关论文
共 50 条
  • [41] Effect of laser pulse energies in laser induced breakdown spectroscopy in double-pulse configuration
    Benedetti, PA
    Cristoforetti, G
    Legnaioli, S
    Palleschi, V
    Pardini, L
    Salvetti, A
    Tognoni, E
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2005, 60 (11) : 1392 - 1401
  • [42] Orthogonal and Collinear Configurations in Double-Pulse Laser-Induced Breakdown Spectrometry to Improve Sensitivity in Chlorine Determination
    A. S. Zakuskin
    A. M. Popov
    S. M. Zaytsev
    N. B. Zorov
    M. V. Belkov
    T. A. Labutin
    Journal of Applied Spectroscopy, 2017, 84 : 319 - 323
  • [43] Investigation of the osteitis deformans phases in snake vertebrae by double-pulse laser-induced breakdown spectroscopy
    Galiova, M.
    Kaiser, J.
    Novotny, K.
    Ivanov, M.
    Fisakova, M. Nyvltova
    Mancini, L.
    Tromba, G.
    Vaculovic, T.
    Liska, M.
    Kanicky, V.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 398 (02) : 1095 - 1107
  • [44] Effect of target composition on the emission enhancement observed in Double-Pulse Laser-Induced Breakdown Spectroscopy
    Cristoforetti, G.
    Legnaioli, S.
    Palleschi, V.
    Salvetti, A.
    Tognoni, E.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2008, 63 (02) : 312 - 323
  • [45] Effect of parameters on Si plasma emission in collinear double-pulse laser-induced breakdown spectroscopy
    Fang-Fang Chen
    Xue-Jiao Su
    Wei-Dong Zhou
    Frontiers of Physics, 2015, 10
  • [46] Effect of parameters on Si plasma emission in collinear double-pulse laser-induced breakdown spectroscopy
    Chen, Fang-Fang
    Su, Xue-Jiao
    Zhou, Wei-Dong
    FRONTIERS OF PHYSICS, 2015, 10 (05)
  • [47] Semiquantitative analysis of mercury in landfill leachates using double-pulse laser-induced breakdown spectroscopy
    Menegatti, Carlos R.
    Nicolodelli, Gustavo
    Senesi, Giorgio S.
    da Silva, Otavio A.
    Filho, Helcio J. I.
    Villas Boas, Paulino R.
    Marangoni, Bruno S.
    Milori, Debora M. B. P.
    APPLIED OPTICS, 2017, 56 (13) : 3730 - 3735
  • [48] Plasma property effects on spectral line broadening in double-pulse laser-induced breakdown spectroscopy
    Choi, Inhee
    Mao, Xianglei
    Gonzalez, J. Jhanis
    Russo, Richard E.
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2013, 110 (04): : 785 - 792
  • [49] In situ analysis of steel melt by double-pulse laser-induced breakdown spectroscopy with a Cassegrain telescope
    Sun, Lanxiang
    Yu, Haibin
    Cong, Zhibo
    Xin, Yong
    Li, Yang
    Qi, Lifeng
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2015, 112 : 40 - 48
  • [50] Orthogonal and Collinear Configurations in Double-Pulse Laser-Induced Breakdown Spectrometry to Improve Sensitivity in Chlorine Determination
    Zakuskin, A. S.
    Popov, A. M.
    Zaytsev, S. M.
    Zorov, N. B.
    Belkov, M. V.
    Labutin, T. A.
    JOURNAL OF APPLIED SPECTROSCOPY, 2017, 84 (02) : 319 - 323