Closed-loop identification and control of multivariable chemical processes: a case study

被引:0
|
作者
Marchetti, G [1 ]
Tognini, F [1 ]
Scali, C [1 ]
机构
[1] Univ Pisa, Dipartimento Ingn Chim, CPCLab, DICCISM, Pisa, Italy
关键词
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Closed-loop identification methods based on relay techniques have been analyzed and compared with open loop methods for an application to a multivariable nonlinear chemical process (a distillation unit: C-3 - C-4 splitter). Classical relay techniques and a recently proposed method for identification and control design (ATV(+)) are applied in a sequential procedure which leads to the design of decentralised controllers. Several disadvantages of open-loop identification techniques have been put into evidence, mainly the inconsistency of the obtained results in the case of a non linear process (model parameters depend on the amplitude of the perturbations used during the identification). Also, longer times are necessary for the experimental tests and a more complex controller tuning technique is required. Closed loop relay techniques are faster, identify the real dynamics of the system and allow a more direct design of the control system. The ATV(+) technique can be successfully applied to the process under study, after some modifications made necessary by the nonlinear nature of the system.
引用
收藏
页码:163 / 177
页数:15
相关论文
共 50 条
  • [21] Closed-loop identification of a laboratory chemical reactor
    Kozka, S
    Mikles, J
    Fikar, M
    Jelenciak, F
    Dzivak, J
    ROBUST CONTROL DESIGN 2000, VOLS 1 & 2, 2000, 1-2 : 663 - 668
  • [22] Closed-loop identification with application to a chemical reactor
    Mikles, J
    Cirka, L
    Kozka, S
    DYNAMICS & CONTROL OF PROCESS SYSTEMS 1998, VOLUMES 1 AND 2, 1999, : 235 - 240
  • [23] Evaluation of the decentralized closed-loop integrity for multivariable control systems
    He, MJ
    Cai, WJ
    Li, SY
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2005, 44 (10) : 3567 - 3574
  • [24] A Closed-loop Evaluation for Regulatory Control Structure of Multivariable System
    Luo, Xionglin
    Ren, Lihong
    Cao, Pengfei
    Zhao, Ye
    Xu, Feng
    PROCEEDINGS OF THE 10TH WORLD CONGRESS ON INTELLIGENT CONTROL AND AUTOMATION (WCICA 2012), 2012, : 1083 - 1088
  • [25] Model Identification for Closed-loop Multivariable Processes Based on Min-max Critical Frequency Search
    Luo, Yunhui
    Liu, Hongbo
    Cai, Wenjian
    Jia, Lei
    Jia, Zhiping
    Song, Ruifu
    PROCEEDINGS OF THE 10TH WORLD CONGRESS ON INTELLIGENT CONTROL AND AUTOMATION (WCICA 2012), 2012, : 3260 - 3264
  • [26] Closed-loop identification of multivariable systems: With or without excitation of all references?
    Miskovic, L.
    Karimi, A.
    Bonvin, D.
    Gevers, M.
    AUTOMATICA, 2008, 44 (08) : 2048 - 2056
  • [27] Stochastic closed-loop model predictive control of continuous nonlinear chemical processes
    Van Hessem, D
    Bosgra, O
    JOURNAL OF PROCESS CONTROL, 2006, 16 (03) : 225 - 241
  • [28] Closed-loop identification for motion control system
    Zhou, Lei
    Li, Jiangang
    Sheng, Jun
    Cao, Jun
    Li, Zexiang
    2010 8TH WORLD CONGRESS ON INTELLIGENT CONTROL AND AUTOMATION (WCICA), 2010, : 477 - 480
  • [29] IDENTIFICATION OF PROCESSES IN CLOSED-LOOP - IDENTIFIABILITY AND ACCURACY ASPECTS
    GUSTAVSSON, I
    LJUNG, L
    SODERSTROM, T
    AUTOMATICA, 1977, 13 (01) : 59 - 75
  • [30] Case studies on closed-loop identification for MPC
    Zhu, YC
    Butoyi, F