Effect of Sustained Joint Loading on TMJ Disc Nutrient Environment

被引:18
|
作者
Wu, Y. [1 ,2 ]
Cisewski, S. E. [1 ,3 ]
Coombs, M. C. [1 ,3 ]
Brown, M. H. [3 ]
Wei, F. [1 ]
She, X. [1 ]
Kern, M. J. [3 ]
Gonzalez, Y. M. [4 ]
Gallo, L. M. [5 ]
Colombo, V [5 ]
Iwasaki, L. R. [6 ]
Nickel, J. C. [6 ]
Yao, H. [1 ,2 ,3 ]
机构
[1] Clemson Univ, Dept Bioengn, Clemson, SC 29425 USA
[2] MUSC, Dept Orthopaed & Phys Med, Charleston, SC USA
[3] MUSC, Coll Dent Med, Dept Oral Hlth Sci, Charleston, SC USA
[4] Univ Buffalo, Sch Dent Med, Dept Oral Diagnost Sci, Buffalo, NY USA
[5] Univ Zurich, Sch Dent Med, Clin Masticatory Disorders, Zurich, Switzerland
[6] Oregon Hlth & Sci Univ, Sch Dent, Dept Orthodont, Portland, OR 97201 USA
基金
美国国家卫生研究院;
关键词
temporomandibular joint; disc nutrition; compressive loading; solute diffusion; cellular energy metabolism; finite element analysis; FINITE-ELEMENT; TEMPOROMANDIBULAR DISORDERS; INTERVERTEBRAL DISC; OXYGEN; NUTRITION; DIFFUSION; HYPOXIA; GLUCOSE; METABOLISM; EXPRESSION;
D O I
10.1177/0022034519851044
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The temporomandibular joint (TMJ) disc nutrient environment profoundly affects cell energy metabolism, proliferation, and biosynthesis. Due to technical challenges of in vivo measurements, the human TMJ disc extracellular nutrient environment under load, which depends on metabolic rates, solute diffusion, and disc morphometry, remains unknown. Therefore, the study objective was to predict the TMJ disc nutrient environment under loading conditions using combined experimental and computational modeling approaches. Specifically, glucose consumption and lactate production rates of porcine TMJ discs were measured under varying tissue culture conditions (n = 40 discs), and mechanical strain-dependent glucose and lactate diffusivities were measured using a custom diffusion chamber (n = 6 discs). TMJ anatomy and loading area were obtained from magnetic resonance imaging of healthy human volunteers (n = 11, male, 30 +/- 9 y). Using experimentally determined nutrient metabolic rates, solute diffusivities, TMJ anatomy, and loading areas, subject-specific finite element (FE) models were developed to predict the 3-dimensional nutrient profiles in unloaded and loaded TMJ discs (unloaded, 0% strain, 20% strain). From the FE models, glucose, lactate, and oxygen concentration ranges for unloaded healthy human TMJ discs were 0.6 to 4.0 mM, 0.9 to 5.0 mM, and 0% to 6%, respectively, with steep gradients in the anterior and posterior bands. Sustained mechanical loading significantly reduced nutrient levels (P < 0.001), with a critical zone in which cells may die representing approximately 13.5% of the total disc volume. In conclusion, this study experimentally determined TMJ disc metabolic rates, solute diffusivities, and disc morphometry, and through subject-specific FE modeling, revealed critical interactions between mechanical loading and nutrient supply and metabolism for the in vivo human TMJ disc. The results suggest that TMJ disc homeostasis may be vulnerable to pathological loading (e.g., clenching, bruxism), which impedes nutrient supply. Given difficulties associated with direct in vivo measurements, this study provides a new approach to systematically investigate homeostatic and degenerative mechanisms associated with the TMJ disc.
引用
收藏
页码:888 / 895
页数:8
相关论文
共 50 条
  • [31] A novel loading rig to mimic the in vivo environment of the human intervertebral disc
    Le Maitre, C. L.
    Frain, J. F.
    Fotheringham, A. P.
    Freemont, A. J.
    Hoyland, J. A.
    JOURNAL OF PATHOLOGY, 2006, 210 : 28 - 28
  • [32] The effect of removal of the disc on the friction in the temporomandibular joint
    Tanaka, Eiji
    Dalla-Bona, Diego A.
    Iwabe, Tatsunori
    Kawai, Nobuhiko
    Yamano, Eizo
    van Eijden, Theo
    Tanaka, Masao
    Miyauchi, Mutsumi
    Takata, Takashi
    Tanne, Kazuo
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2006, 64 (08) : 1221 - 1224
  • [33] Effect of loading rate and hydration on the mechanical properties of the disc
    Race, A
    Broom, ND
    Robertson, P
    SPINE, 2000, 25 (06) : 662 - 669
  • [34] Lumbar facet joint and intervertebral disc loading during simulated pelvic obliquity
    Popovich, John M., Jr.
    Welcher, Judson B.
    Hedman, Thomas P.
    Tawackoli, Wafa
    Anand, Neel
    Chen, Thomas C.
    Kulig, Kornelia
    SPINE JOURNAL, 2013, 13 (11): : 1581 - 1589
  • [35] Effect of sustained tensile loading on SHCC crack widths
    Boshoff, William P.
    Adendorff, Christo J.
    CEMENT & CONCRETE COMPOSITES, 2013, 37 : 119 - 125
  • [36] Sustained loading effect on the fatigue life of plain concrete
    Zhang, B
    Phillips, DV
    Green, DR
    MAGAZINE OF CONCRETE RESEARCH, 1998, 50 (03) : 263 - 278
  • [37] The effect of disc thickness and trauma on disc surface friction in the porcine temporomandibular joint
    Nickel, JC
    Iwasaki, LR
    Feely, DE
    Stormberg, KD
    Beatty, MW
    ARCHIVES OF ORAL BIOLOGY, 2001, 46 (02) : 155 - 162
  • [38] Laser AsGa Effect on the Normal Anatomy of the Temporo Mandibular Joint (TMJ) on the Rabbit
    Matamala, Fernando
    Cornejo, Ricardo
    Vasconcellos, Adriana
    Silva, Hector
    REVISTA CIENTIFICA-FACULTAD DE CIENCIAS VETERINARIAS, 2009, 19 (01): : 31 - 37
  • [39] Effect of test environment on intervertebral disc hydration
    Pflaster, DS
    Krag, MH
    Johnson, CC
    Haugh, LD
    Pope, MH
    SPINE, 1997, 22 (02) : 133 - 139
  • [40] The effect of bolus properties on muscle activation patterns and TMJ loading during unilateral chewing
    Sagl, Benedikt
    Schmid-Schwap, Martina
    Piehslinger, Eva
    Yao, Hai
    Rausch-Fan, Xiaohui
    Stavness, Ian
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2024, 151