Determination of antimony(III) and (V) in natural water by cathodic stripping voltammetry with in-situ plated bismuth film electrode

被引:39
|
作者
Zong, Ping [1 ]
Nagaosa, Yukio [1 ]
机构
[1] Univ Fukui, Dept Appl Chem & Biotechnol, Grad Sch Engn, Bunkyo Ku, Fukui 9108507, Japan
关键词
Antimony(III); Antimony(V); Speciation analysis; Bismuth film electrode; Square wave cathodic stripping voltammetry; GENERATION; SPECIATION; COPRECIPITATION; SPECTROMETRY; ENVIRONMENT; STABILITY; SAMPLES; LEAD;
D O I
10.1007/s00604-009-0176-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method is described for the sequential determination of Sb(III) and Sb(V) using Osteryoung square wave cathodic stripping voltammetry. It employs an in-situ plated bismuth-film on an edge-plane graphite substrate as the working electrode. Selective electro-deposition of Sb(III)/Sb(V) is accomplished by applying a potential of -500 mV vs. Ag/AgCl, followed by reduction to stibine at a more negative potential in the stripping step. Stripping was carried out by applying a square wave waveform between -500 and -1400 mV to the antimony deposited. The stripping peak current at -1150 mV is directly proportional to the concentration of Sb( III)/Sb(V). The calibration plots for Sb (III) were linear up to 12.0 A mu g L-1 depending on the time of deposition. The calibration plots for Sb (V) were linear up to 7.0 A mu g L-1, also depending on the time of deposition. The relative standard deviation in the determination of 0.1 A mu g L-1 of Sb(III) is 4.0% (n = 5), and the limit of detection is as low as 2 ng L-1. In case of 0.1 A mu g L-1 Sb(V), the relative standard deviation is 3.0% (n = 5) and the detection limit also is 2 ng L-1. The method was applied to the analysis of river and sea water samples.
引用
收藏
页码:139 / 144
页数:6
相关论文
共 50 条
  • [41] Determination of Manganese by Cathodic Stripping Voltammetry on a Microfabricated Platinum Thin-film Electrode
    Kang, Wenjing
    Rusinek, Cory
    Bange, Adam
    Haynes, Erin
    Heineman, William R.
    Papautsky, Ian
    ELECTROANALYSIS, 2017, 29 (03) : 686 - 695
  • [42] Determination of Diazepam, Temazepam and Oxazepam at the Lead Film Electrode by Adsorptive Cathodic Stripping Voltammetry
    Tyszczuk, Katarzyna
    ELECTROANALYSIS, 2010, 22 (17-18) : 1975 - 1984
  • [43] Determination of Se(IV) by adsorptive cathodic stripping voltammetry at a Bi/Hg film electrode
    Sharifian, Parisa
    Aliakbar, Alireza
    ANALYTICAL METHODS, 2015, 7 (05) : 2121 - 2128
  • [44] STRIPPING VOLTAMMETRY OF TRACES OF ANTIMONY(III) AND ANTIMONY(V) IN NATURAL-WATERS AFTER SELECTIVE EXTRACTION
    METZGER, M
    BRAUN, H
    ANALYTICA CHIMICA ACTA, 1986, 189 (02) : 263 - 275
  • [45] DETERMINATION OF SMALL AMOUNTS OF BISMUTH IN ANTIMONY(III) OXIDE BY USING ANODIC-STRIPPING VOLTAMMETRY
    PETAK, P
    KOUBOVA, V
    ANALYST, 1978, 103 (1223) : 179 - 182
  • [46] Determination of Antimony (III) in Real Samples by Anodic Stripping Voltammetry Using a Mercury Film Screen-Printed Electrode
    Dominguez-Renedo, Olga
    Gomez Gonzalez, M. Jesus
    Julia Arcos-Martinez, M.
    SENSORS, 2009, 9 (01) : 219 - 231
  • [47] Determination of trace selenium by differential pulse adsorptive stripping voltammetry at a bismuth film electrode
    Zhang, Qing
    Li, Xiangjun
    Shi, Hui
    Hongzhou
    Yuan, Zhuobin
    ELECTROCHIMICA ACTA, 2010, 55 (16) : 4717 - 4721
  • [48] Determination of Lead in Ambient Aerosol Samples by Anodic Stripping Voltammetry on a Bismuth Film Electrode
    Palomo Marin, Ma Rosario
    Pinilla Gil, Eduardo
    Calvo Blazquez, Lorenzo
    ELECTROANALYSIS, 2011, 23 (01) : 215 - 221
  • [49] Graphene Oxide-Modified Electrode Coated with in-situ Antimony Film for the Simultaneous Determination of Heavy Metals by Sequential Injection-Anodic Stripping Voltammetry
    Ruengpirasiri, Prasongporn
    Punrat, Eakkasit
    Chailapakul, Orawon
    Chuanuwatanakul, Suchada
    ELECTROANALYSIS, 2017, 29 (04) : 1022 - 1030
  • [50] Determination of Water in Room Temperature Ionic Liquids by Cathodic Stripping Voltammetry at a Gold Electrode
    Zhao, Chuan
    Bond, Alan M.
    Lu, Xunyu
    ANALYTICAL CHEMISTRY, 2012, 84 (06) : 2784 - 2791