Comparison of left ventricular ejection fraction by single photon computed tomographic myocardial perfusion imaging versus coronary computed tomography angiography

被引:0
|
作者
Rajdev, Archana [1 ]
Aronow, Wilbert S. [1 ]
Lai, Hoang M. [1 ]
Ravipati, Gautham [1 ]
DeLuca, Albert J. [1 ]
Weiss, Melvin B. [1 ]
Belkin, Robert N. [1 ]
机构
[1] New York Med Coll, Div Cardiol, Dept Med, Valhalla, NY 10595 USA
关键词
left ventricular ejection fraction; myocardial perfusion imaging; coronary computed tomography angiography; CONGESTIVE-HEART-FAILURE; DILATED CARDIOMYOPATHY; ECHOCARDIOGRAPHY; VOLUMES; SECONDARY; ACCURACY;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Measurement of left ventricular (LV) ejection fraction by coronary computed tomography angiography (CTA) vs. single photon computed tomographic myocardial perfusion imaging (MPI) needs to be investigated. Material and methods: Myocardial perfusion imaging and CTA were performed in 292 patients because of chest pain or dyspnea. The patients included 178 men and 114 women, mean age 66 +/- 11 years. Results: The mean LV ejection fraction was 61 +/- 12% for the MPI tests and 65 +/- 11% for CTA (p <0.001). The LV ejection fraction was >= 50% in 250 of 292 patients (86%) with MPI testing and in 266 of 292 patients (91%) with CTA (p < 0.05). The LV ejection fraction was 36-49% in 31 of 292 patients (11%) with MPI testing and in 22 of 292 patients (8%) with CTA (p not significant). The LV ejection fraction was <= 35% in 11 of 292 patients (4%) with MPI testing and in 4 of 292 patients (1%) with CTA (p not significant). Pearson correlation coefficient was R = 0.67, p < 0.001. Conclusions: The resting LV ejection fraction is significantly higher in patients measured by CTA than in patients measured by MPI testing when both tests are performed in the same patients.
引用
收藏
页码:28 / 31
页数:4
相关论文
共 50 条
  • [41] The Impact of Left Ventricle Ejection Fraction Reduction and Transient Ischemic Dilation in Patients With Normal Single-Photon Emission Computed Tomography (SPECT) Myocardial Perfusion Imaging
    Medeiros, Paulo
    Pereira, Barbara
    Rodrigues, Jorge
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (12)
  • [42] Comparison of two-dimensional echocardiographic tissue harmonic imaging and gated sestamibi single-photon emission computed tomographic left ventricular ejection fraction measurements
    Belkin, RN
    Ghosh, J
    Deluca, AJ
    Alas, LA
    Murphy, JJ
    McClung, JA
    Visintainer, P
    Sarabu, BR
    Aronow, WS
    AMERICAN JOURNAL OF CARDIOLOGY, 2003, 92 (06): : 759 - 762
  • [43] Anatomical versus functional severity of coronary artery stenoses using coronary computed tomography angiography and myocardial perfusion imaging
    Fukuda, H.
    Moroi, M.
    Masai, H.
    Kunimasa, T.
    Nakazato, R.
    Furuhashi, T.
    Sugi, K.
    EUROPEAN HEART JOURNAL, 2011, 32 : 830 - 830
  • [44] 3D Image fusion of cardiac computed tomographic angiography (CCTA) and single-photon emission computed tomography myocardial perfusion imaging (SPECT-MPI)
    Higashino, Hiroshi
    Kido, Teruhito
    Watanabe, Kouki
    Mochizuki, Teruhito
    Higaki, Toru
    Goko, Yasuaki
    Nagao, Michinobu
    Kurata, Akira
    Hosokawa, Kouhei
    Kido, Tomoyuki
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [45] The value of pretest risk stratification before coronary computed tomographic angiography and myocardial perfusion imaging
    Koh, H.
    Chia, S.
    Allen, J. C.
    Chua, T.
    Ng, R.
    Keng, F.
    Cheah, F. K.
    Tan, S. Y.
    EUROPEAN HEART JOURNAL, 2012, 33 : 135 - 135
  • [46] Left ventricular mass from gated SPECT myocardial perfusion imaging: Comparison with cardiac computed tomography
    Okwuosa, Tochi M.
    Hampole, Chetan V.
    Ali, Javid
    Williams, Kim A.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2009, 16 (05) : 775 - 783
  • [47] Left ventricular mass from gated SPECT myocardial perfusion imaging: Comparison with cardiac computed tomography
    Tochi M. Okwuosa
    Chetan V. Hampole
    Javid Ali
    Kim A. Williams
    Journal of Nuclear Cardiology, 2009, 16 : 775 - 783
  • [48] Diagnostic performance of fusion of myocardial perfusion imaging (MPI) and computed tomography coronary angiography
    Cesar A. Santana
    Ernest V. Garcia
    Tracy L. Faber
    Gopi K. R. Sirineni
    Fabio P. Esteves
    Rupan Sanyal
    Raghuveer Halkar
    Mario Ornelas
    Liudmila Verdes
    Stamatios Lerakis
    Julie J. Ramos
    Santiago Aguadé-Bruix
    Hugo Cuéllar
    Jaume Candell-Riera
    Paolo Raggi
    Journal of Nuclear Cardiology, 2009, 16 : 201 - 211
  • [49] Evaluation of coronary artery disease with coronary computed tomography angiography and single photon emission computed tomography
    Alexanderson, Erick E.
    Herrera, M.
    Calleja, R.
    Martinez, A. J.
    Ochoa, J. M.
    Alcantara, M.
    Meave, A.
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2009, 11 (0B) : S39 - S39
  • [50] Diagnostic performance of fusion of myocardial perfusion imaging (MPI) and computed tomography coronary angiography
    Santana, Cesar A.
    Garcia, Ernest V.
    Faber, Tracy L.
    Sirineni, Gopi K. R.
    Esteves, Fabio P.
    Sanyal, Rupan
    Halkar, Raghuveer
    Ornelas, Mario
    Verdes, Liudmila
    Lerakis, Stamatios
    Ramos, Julie J.
    Aguade-Bruix, Santiago
    Cuellar, Hugo
    Candell-Riera, Jaume
    Raggi, Paolo
    JOURNAL OF NUCLEAR CARDIOLOGY, 2009, 16 (02) : 201 - 211