Electrical Detection of Nucleic Acid Amplification Using an On-Chip Quasi-Reference Electrode and a PVC REFET

被引:38
|
作者
Salm, Eric [1 ,2 ]
Zhong, Yu [2 ,3 ]
Reddy, Bobby, Jr. [2 ,3 ]
Duarte-Guevara, Carlos [2 ,3 ]
Swaminathan, Vikhram [2 ,4 ]
Liu, Yi-Shao [5 ]
Bashir, Rashid [1 ,2 ,3 ]
机构
[1] Univ Illinois, Dept Bioengn, Urbana, IL 61801 USA
[2] Micro & Nanotechnol Lab, Urbana, IL 61801 USA
[3] Univ Illinois, Dept Elect & Comp Engn, Urbana, IL 61801 USA
[4] Univ Illinois, Dept Mech Sci & Engn, Urbana, IL 61801 USA
[5] Taiwan Semicond Mfg Co, Hsinchu, Taiwan
基金
美国农业部;
关键词
DNA-POLYMERASE REACTIONS; FIELD-EFFECT TRANSISTORS; REAL-TIME; PCR; OXIDES;
D O I
10.1021/ac500897t
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Electrical detection of nucleic acid amplification through pH changes associated with nucleotide addition enables miniaturization, greater portability of testing apparatus, and reduced costs. However, current ion-sensitive field effect transistor methods for sensing nucleic acid amplification rely on establishing the fluid gate potential with a bulky, difficult to microfabricate reference electrode that limits the potential for massively parallel reaction detection. Here we demonstrate a novel method of utilizing a microfabricated solid-state quasi-reference electrode (QRE) paired with a pH-insensitive reference field effect transistor (REFET) for detection of real-time pH changes. The end result is a 0.18 mu m, silicon-on-insulator, foundry-fabricated sensor that utilizes a platinum QRE to establish a pH-sensitive fluid gate potential and a PVC membrane REFET to enable pH detection of loop mediated isothermal amplification (LAMP). This technique is highly amendable to commercial scale-up, reduces the packaging and fabrication requirements for ISFET pH detection, and enables massively parallel droplet interrogation for applications, such as monitoring reaction progression in digital PCR.
引用
收藏
页码:6968 / 6975
页数:8
相关论文
共 50 条
  • [11] On-Chip Isothermal Nucleic Acid Amplification on Flow-Based Chemiluminescence Microarray Analysis Platform for the Detection of Viruses and Bacteria
    Kunze, A.
    Dilcher, M.
    Abd El Wahed, A.
    Hufert, F.
    Niessner, R.
    Seidel, M.
    ANALYTICAL CHEMISTRY, 2016, 88 (01) : 898 - 905
  • [12] Multifunctional Sample Preparation Kit and On-Chip Quantitative Nucleic Acid Sequence-Based Amplification Tests for Microbial Detection
    Zhao, Xinyan
    Dong, Tao
    ANALYTICAL CHEMISTRY, 2012, 84 (20) : 8541 - 8548
  • [13] Rapid on-site nucleic acid testing: On-chip sample preparation, amplification, and detection, and their integration into all-in-one systems
    Wang, Jingwen
    Jiang, Han
    Pan, Leiming
    Gu, Xiuying
    Xiao, Chaogeng
    Liu, Pengpeng
    Tang, Yulong
    Fang, Jiehong
    Li, Xiaoqian
    Lu, Chenze
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2023, 11
  • [14] Effect of the working and counter/quasi-reference electrode relative area ratio of silver sensor electrodes on voltammetric detection of Pb(II)
    Lee, Yong-Gu
    Jang, Am
    JOURNAL OF INDUSTRIAL AND ENGINEERING CHEMISTRY, 2020, 81 : 67 - 70
  • [15] On-Chip Nucleic Acid Purification Followed by ddPCR for SARS-CoV-2 Detection
    Ma, Cong
    Sun, Yimeng
    Huang, Yuhang
    Gao, Zehang
    Huang, Yaru
    Pandey, Ikshu
    Jia, Chunping
    Feng, Shilun
    Zhao, Jianlong
    BIOSENSORS-BASEL, 2023, 13 (05):
  • [16] Integration of On-Chip Isotachophoresis and Functionalized Hydrogels for Enhanced-Sensitivity Nucleic Acid Detection
    Garcia-Schwarz, Giancarlo
    Santiago, Juan G.
    ANALYTICAL CHEMISTRY, 2012, 84 (15) : 6366 - 6369
  • [17] Faradaic-free electrokinetic nucleic acid amplification (E-NAAMP) using localized on-chip high frequency Joule heating
    Yost, Jarad
    Gagnon, Zachary
    BIOMICROFLUIDICS, 2022, 16 (01)
  • [18] HIGHLY SENSITIVE DETECTION OF MICRORNAS BY USING TECHNIQUES OF NUCLEIC ACID AMPLIFICATION
    Li Zhengping
    Wang Honghong
    Jia Hongxia
    Cheng Yongqiang
    PROGRESS ON POST-GENOME TECHNOLOGIES AND MODERN NATURAL PRODUCTS, 2011, 2011, : 39 - 40
  • [19] Nucleic acid detection using G-quadruplex amplification methodologies
    Roembke, Benjamin T.
    Nakayama, Shizuka
    Sintim, Herman O.
    METHODS, 2013, 64 (03) : 185 - 198
  • [20] A novel flexible Ag/AgCl quasi-reference electrode based on silver nanowires toward ultracomfortable electrophysiology and sensitive electrochemical glucose detection
    Sun, Jing
    Wang, Qingxiang
    Luo, Gang
    Meng, Weichen
    Cao, Meng
    Li, Yanzhao
    Masterman-Smith, Michael D.
    Yang, Haibo
    Sun, Xudong
    Lang, Ming-Fei
    JOURNAL OF MATERIALS RESEARCH AND TECHNOLOGY-JMR&T, 2020, 9 (06): : 13425 - 13433