Electrochemical sensor for sulfadimethoxine based on molecularly imprinted polypyrrole: Study of imprinting parameters

被引:91
|
作者
Turco, Antonio [1 ]
Corvaglia, Stefania [2 ]
Mazzotta, Elisabetta [1 ]
机构
[1] Univ Salento, Dipartimento Sci & Tecnol Biol & Ambientali DiSTe, I-73100 Lecce, Italy
[2] Elettra Sincrotrone Trieste SCpA, NanoInnovat Lab, I-34149 Trieste, Italy
来源
关键词
Electrosynthesis of molecularly imprinted polymer; Molecularly imprinted overoxidized polypyrrole; Sulfadimethoxine amperometric detection; PERFORMANCE LIQUID-CHROMATOGRAPHY; DOPED DIAMOND ELECTRODE; OVEROXIDIZED POLYPYRROLE; AMPEROMETRIC DETECTION; CHEMICAL-STRUCTURE; SULFONAMIDES; FILMS; ANTIBIOTICS; POLYMERS; DRUGS;
D O I
10.1016/j.bios.2014.07.045
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The present work describes the development of a simple and cost-effective electrochemical sensor for sulfadimethoxine (SDM) based on molecularly imprinted overoxidized polypyrrole (PPy). An all electrochemical approach is used for sensor fabrication and application consisting in molecularly imprinted polymer (MIP) galvanostatic deposition on a gold electrode and its overoxidation under different experimental conditions and in SDM amperometric detection. Several parameters influencing the imprinting effect are critically discussed and evaluated. A key role of the electrolyte used in electropolymerization (tetrabuthylammonium perchlorate and lithium perchlorate) has emerged demonstrating its effect on sensing performances of imprinted PPy and, related to this, on its morphology, as highlighted by atomic force microscopy (AFM). The effect of different overoxidation conditions in removing template is evaluated by analyzing MIP films before and after the treatment by X-ray photoelectron spectroscopy (XPS) also evidencing the correlation between MIP chemical structure and its rebinding ability. MIP-template interaction is verified also by Fourier Transform Infrared (FT-IR) spectroscopy. Under the selected optimal conditions, MIP sensor shows a linear range from 0.15 to 3.7 mM SDM, a limit of detection of 70 mu M, a highly reproducible response (RSD 4.2%) and a good selectivity in the presence of structurally related molecules. SDM was determined in milk samples spiked at two concentration levels: 0.2 mM and 0.4 mM obtaining a satisfactory recovery of (97 +/- 3)% and (96 +/- 8)%, respectively. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:240 / 247
页数:8
相关论文
共 50 条
  • [31] Electrochemical sensors based on L-tryptophan molecularly imprinted polypyrrole and polyaniline
    Ratautaite, Vilma
    Brazys, Ernestas
    Ramanaviciene, Almira
    Ramanavicius, Arunas
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2022, 917
  • [32] Electrochemical Sensor Based on Molecularly Imprinted Polymer for the Detection of Cefalexin
    Feier, Bogdan
    Blidar, Adrian
    Pusta, Alexandra
    Carciuc, Paula
    Cristea, Cecilia
    BIOSENSORS-BASEL, 2019, 9 (01):
  • [33] Sulfamethazine and sulfadimethoxine separation strategies based on molecularly imprinted adsorbents
    Hung, Chin-Yin
    Huang, Yun-Tzu
    Huang, Han-Hung
    Hwang, Ching-Chiang
    ANALYTICAL LETTERS, 2007, 40 (16-18) : 3232 - 3244
  • [34] Computational study and multivariate optimization of hydrochlorothiazide analysis using molecularly imprinted polymer electrochemical sensor based on carbon nanotube/polypyrrole film
    Nezhadali, Azizollah
    Mojarrab, Maliheh
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 190 : 829 - 837
  • [35] Towards Molecularly Imprinted Polypyrrole-Based Sensor for the Detection of Methylene Blue
    Boguzaite, Raimonda
    Pilvenyte, Greta
    Ratautaite, Vilma
    Brazys, Ernestas
    Ramanaviciene, Almira
    Ramanavicius, Arunas
    CHEMOSENSORS, 2023, 11 (11)
  • [36] A rapid and recyclable analysis method for sulfadimethoxine detection based on molecularly imprinted electrochemical sensor reinforced by GQDs/ZIF-8 nanocomposite
    Hatamluyi, Behnaz
    Sadeghzadeh, Samira
    Zehi, Zakiyeh Balouch
    Rezayi, Majid
    Sany, Seyedeh Belin Tavakoly
    MICROCHEMICAL JOURNAL, 2023, 185
  • [37] Preparation and application of chlortetracycline electrochemical sensor based on molecularly imprinting technique
    Han S.
    Zhang N.
    Wang H.
    Zhang X.
    Yang J.
    Zhang M.
    Zhang Z.
    Huagong Xuebao/CIESC Journal, 2022, 73 (08): : 3758 - 3767
  • [38] Preparation and Application of Semicarbazide Electrochemical Sensor Based on Molecularly Imprinting Technique
    Li Jian-Wen
    Wei Shou-Lian
    Jiang Jie-Tao
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2016, 44 (01) : 103 - 109
  • [39] Preparation and Application of Electrochemical Barbital Sensor Based on Molecularly Imprinting Technique
    ZHENG Jing
    ZHANG Yan
    GUO Mandong
    Wuhan University Journal of Natural Sciences, 2017, 22 (03) : 207 - 214
  • [40] Electrochemical sensor based on molecularly imprinted polypyrrole-MWCNTs-OH/covalent organic framework for the detection of ofloxacin in water
    Huang, Lijuan
    Luo, Yuan
    Li, Xulin
    Wu, Juan
    Long, Qian
    Zheng, Li
    Liao, Wenlong
    Li, Huiming
    Jia, Lingpu
    Liu, Kunping
    MICROCHIMICA ACTA, 2025, 192 (01)