A holistic performance assessment of duct-type electrostatic precipitators

被引:21
|
作者
Wang, Pan [1 ]
Liu, Junjie [1 ]
Wang, Chenhua [1 ]
Zhang, Zhiwei [1 ]
Li, Jiayu [2 ,3 ]
机构
[1] Tianjin Univ, Sch Environm Sci & Engn, Tianjin Key Lab Indoor Air Environm Qual Control, Tianjin 300072, Peoples R China
[2] Berkeley Educ Alliance Res Singapore, Singapore 138602, Singapore
[3] Berkeley Educ Alliance Res Singapore, 1 Create Way,11-02 Create Tower, Singapore 138602, Singapore
关键词
Electrostatic precipitator; Filtration efficiency; Dust loading; Washing; Ozone emission rate; Quality factor; PARTICLE REMOVAL; OZONE GENERATION; FINE PARTICLES; FILTRATION CHARACTERISTICS; SUBMICRON PARTICLES; VENTILATION SYSTEMS; PRESSURE-DROP; AIR FILTER; IN-DUCT; COLLECTION;
D O I
10.1016/j.jclepro.2022.131997
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Epidemiological surveys have shown a significant association between indoor airborne particle exposure and adverse health effects. Duct-type electrostatic precipitators (ESPs) are effective in controlling airborne particles in buildings. Although several studies have examined the initial performance of duct-type ESPs, there are no comprehensive data on the holistic performance of commercially available ESPs. In addition, there are no published comparisons of the performance of ESPs with and without dielectric coatings considering the impact of dust loading and washing. In this study, laboratory tests were conducted to determine the holistic performance including initial, dust-loaded, and postwashing filtration efficiencies and ozone emission rates of ESPs with and without dielectric coatings. ESPs with dielectric coatings showed enhanced removal efficiency of submicron particles, with overall efficiencies comparable to those of F7 filters and 85% lower energy consumption. The removal efficiency of the ESP with dielectric coatings was superior to those of ESPs without dielectric coatings, but the higher energy consumption of the former led to slightly lower comprehensive performance. The filtration efficiency for submicron particles differed most between the two types of ESPs and was more suitable for evaluating their performance. The ozone emission rates were almost 2-7 times higher for ESPs without dielectric coatings than for the ESP with a dielectric coating (5.9 +/- 2.2 mg/h). Based on the initial comprehensive quality factors of the ESPs, the maximum reductions caused by dust loading and washing were 55.3% and 17.5%, respectively. This study demonstrates the importance of considering multiple criteria when evaluating the performance of duct-type ESPs.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Pancreatic duct lavage cytology for the diagnosis of branch duct-type intraductal papillary mucinous neoplasm of the pancreas
    Sai, Jin Kan
    Suyama, Masafumi
    Kubokawa, Yoshihiro
    Watanabe, Sumio
    [J]. PANCREAS, 2008, 36 (02) : 216 - 217
  • [32] Analysis of Collection Efficiency in Wire-Duct Electrostatic Precipitators Subjected to the Applied Magnetic Field
    Zhang, Jian-Ping
    Ding, Quan-Fei
    Dai, Yong-Xia
    Ren, Jian-Xing
    [J]. IEEE TRANSACTIONS ON PLASMA SCIENCE, 2011, 39 (01) : 569 - 575
  • [33] Solutions to improve dust collection with plate-type electrostatic precipitators
    Popa, Gabriel Nicolae
    Sora, Ioan
    Vaida, Victor
    Deaconu, Sorin
    Popa, Iosif
    [J]. PROCEEDINGS OF THE 9TH WSEAS INTERNATIONAL CONFERENCE ON AUTOMATION AND INFORMATION, 2008, : 282 - +
  • [34] Enhanced Performance for Electrostatic Precipitators by Means of Conventional and Fuzzy Logic Control
    Grass, Norbert
    Zintl, Andreas
    Hoffmann, Enrico
    [J]. 2008 IEEE INDUSTRY APPLICATIONS SOCIETY ANNUAL MEETING, VOLS 1-5, 2008, : 54 - +
  • [35] Experimental Analysis for Plate-Type Electrostatic Precipitators with Three Sections
    Popa, Gabriel Nicolae
    Deaconu, Sorin Ioan
    Popa, Iosif
    Dinis, Corina Maria
    [J]. PROCEEDINGS OF THE 13TH INTERNATIONAL CONFERENCE ON OPTIMIZATION OF ELECTRICAL AND ELECTRONIC EQUIPMENT, VOLS 1-5, 2012, : 1274 - 1279
  • [36] Analytic Model and Transmission Reduction Performance of Duct-type Acoustic Metamaterials based on Multiple Side-branch Resonators
    Lee, Soo Yeong
    Lee, Joong Seok
    [J]. TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS A, 2020, 44 (10) : 707 - 716
  • [37] MATHEMATICAL-MODEL FOR CALCULATING EFFECTS OF BACK CORONA IN WIRE-DUCT ELECTROSTATIC PRECIPITATORS
    LAWLESS, PA
    SPARKS, LE
    [J]. JOURNAL OF APPLIED PHYSICS, 1980, 51 (01) : 242 - 256
  • [38] PERFORMANCE OF LARGE-DIAMETER WIRES AS DISCHARGE ELECTRODES IN ELECTROSTATIC PRECIPITATORS
    PONTIUS, DH
    BUSH, PV
    SPARKS, LE
    [J]. JOURNAL OF THE AIR POLLUTION CONTROL ASSOCIATION, 1984, 34 (12): : 1203 - 1207
  • [39] Methodology for performance evaluation of dust control systems with an application to electrostatic precipitators
    Economopoulou, Alexia A.
    Harrison, Roy M.
    [J]. AEROSOL SCIENCE AND TECHNOLOGY, 2008, 42 (10) : 842 - 853
  • [40] An Analysis of the High Voltage Sources Used for Small Cylindrical Type Electrostatic Precipitators
    Popa, Gabriel N.
    Dinis, Corina M.
    Iagar, Angela
    Deaconu, Sorin, I
    [J]. 2021 12TH INTERNATIONAL SYMPOSIUM ON ADVANCED TOPICS IN ELECTRICAL ENGINEERING (ATEE), 2021,