Effects of an intra-ventricular assist device on the stroke volume of failing ventricle: Analysis of a mock circulatory system

被引:4
|
作者
Zhu, Shidong [1 ]
Luo, Lin [1 ]
Yang, Bibo [2 ]
Ni, Kai [1 ]
Zhou, Qian [1 ]
Li, Xinghui [1 ]
Wang, Xiaohao [1 ]
机构
[1] Tsinghua Univ, Div Adv Mfg, Grad Sch Shenzhen, Shenzhen 518055, Guangdong, Peoples R China
[2] Capital Med Univ, Beijing Anzhen Hosp, Cardiac Surg Ctr, Beijing 100029, Peoples R China
关键词
Left ventricular assist device; mock circulatory system; pulsatile pump; stroke volume; PISTON BLOOD PUMPS; SUPPORT-SYSTEMS; HEART-FAILURE; FLOW; PULSATILE; COUNTERPULSATION; PERFORMANCE; MODEL;
D O I
10.3233/THC-174752
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
BACKGROUND: A novel intra-ventricular assist device (iVAD) was established as a new pulsatile assist device to address various disadvantages, such as bulky configuration and reduced arterial pulsatility, observed in conventional ventricular assist devices. OBJECTIVE: Analyzed the native left ventricular stroke volume (SV) after iVAD support in vitro. METHODS: The SV of iVAD was examined in a home-designed mock circulatory system (MCS) at different heart rates and drive pressures and the SV of a failure ventricle was examined with iVAD at 75, 90, 120 bpm and 120-180 mmHg drive pressure after iVAD support. Data pertaining to native left ventricular SV before and after iVAD support were compared. RESULTS: The native ventricular SV was improved by iVAD when its drive pressure (DP) was slightly greater than that of the mock system. Conversely, the native ventricular SV was decreased when DP was much greater than that (150 mmHg) of MCS. A high DP had a significant effect on SV. CONCLUSIONS: The proposed device improved the dysfunctional native left ventricular SV when DP of iVAD was slightly greater than that of MCS. However, iVAD reduced the SV when the drive pressure was greater than that of MCS.
引用
收藏
页码:S471 / S479
页数:9
相关论文
共 50 条
  • [1] Elastance Control of a Mock Circulatory System for Ventricular Assist Device Test
    Yu, Yih-Choung
    Gopalakrishnan, Sriram
    2009 AMERICAN CONTROL CONFERENCE, VOLS 1-9, 2009, : 1009 - 1014
  • [2] In vitro testing of an intra-ventricular assist device
    Zhu, Shidong
    Luo, Lin
    Yang, Bibo
    Li, Xinghui
    Ni, Kai
    Zhou, Qian
    Wang, Xiaohao
    COMPUTER ASSISTED SURGERY, 2019, 24 : 89 - 95
  • [3] Pumping Rate Study of a Left Ventricular Assist Device in a Mock Circulatory System
    Zhuang, Xiaoqi
    Yang, Ming
    Xu, Liang
    Ou, Wenchu
    Xu, Zihao
    Meng, Fan
    Huang, Huan
    ASAIO JOURNAL, 2016, 62 (04) : 410 - 420
  • [4] A novel intra-ventricular assist device enhances cardiac performance in normal and acutely failing isolated porcine hearts
    van Dort, Daniel I. M.
    Thannhauser, Jos
    Morshuis, Wim J.
    Geuzebroek, Guillaume S. C.
    Duncker, Dirk J.
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2022, 45 (04): : 388 - 396
  • [5] A HYBRID MOCK CIRCULATORY SYSTEM FOR CARDIOVASCULAR ASSIST DEVICE VALIDATION
    Cheng, S. J.
    Hsu, P-L
    McMahon, R. A.
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2010, 33 (07): : 446 - 446
  • [6] MOCK CIRCULATORY-SYSTEM FOR IN-VITRO REPRODUCTION OF THE LEFT-VENTRICLE, THE ARTERIAL TREE AND THEIR INTERACTION WITH A LEFT-VENTRICULAR ASSIST DEVICE
    FERRARI, G
    DELAZZARI, C
    MIMMO, R
    AMBROSI, D
    TOSTI, G
    JOURNAL OF MEDICAL ENGINEERING & TECHNOLOGY, 1994, 18 (03) : 87 - 95
  • [7] Mechanical Circulatory Support for Failing Systemic Right Ventricle Using Left Ventricular Assist Device - An Option To Decide and Bridge?
    Peng, E.
    Griselli, M.
    O'Sullivan, J.
    Crossland, D.
    Chaudhari, M.
    Wrightson, N.
    Butt, T.
    Roysam, C.
    Parry, G.
    MacGowan, G. A.
    Schueler, S.
    Hasan, A.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2014, 33 (04): : S58 - S59
  • [8] ANALYSIS OF AN ARTIFICIAL VENTRICLE AND MOCK CIRCULATORY-SYSTEM
    HIGH, KM
    BRIGHTON, JA
    BRICKMAN, AD
    PIERCE, WS
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1977, 99 (04): : 184 - 188
  • [9] A Fast Building and Effective Hydraulic Pediatric Mock Circulatory System for the Evaluation of a Left Ventricular Assist Device
    Huang, Feng
    Ruan, Xiaodong
    Zou, Jun
    Qian, Wenwei
    Fu, Xin
    ASAIO JOURNAL, 2013, 59 (06) : 575 - 585
  • [10] Estimation of Left Ventricular Preload Using Left Ventricular Assist Device Flow Waveform Analysis in a Mock Circulatory Loop
    Ramanayake, A.
    Barua, S.
    Robson, D.
    Adji, A.
    Hayward, C. S.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2022, 41 (04): : S229 - S230