Comparison of the shaping abilities of three nickel-titanium instrumentation systems using micro-computed tomography

被引:5
|
作者
Baek, Jin Yi [1 ]
Yoo, Hyun Mi [1 ]
Park, Dong Sung [1 ]
Oh, Tae Seok [1 ]
Kum, Kee Yeon [2 ,3 ]
Shin, Seung Yun [4 ]
Chang, Seok Woo [5 ]
机构
[1] Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Dept Conservat Dent,Inst Oral Hlth Sci, Seoul, South Korea
[2] Seoul Natl Univ, Sch Dent, Dent Hosp, Dept Conservat Dent,Dent Res Inst, Seoul, South Korea
[3] Seoul Natl Univ, Sch Dent, Program BK21, Dent Hosp, Seoul, South Korea
[4] Kyung Hee Univ, Sch Dent, Dept Periodontol, Seoul 130701, South Korea
[5] Kyung Hee Univ, Sch Dent, Dept Conservat Dent, Seoul 130701, South Korea
基金
新加坡国家研究基金会;
关键词
canal shaping; centering ratio; micro-computed tomography; nickel-titanium instruments; transportation; ROOT-CANAL PREPARATION; SELF-ADJUSTING FILE; ROTARY INSTRUMENTS; TRANSPORTATION; PROTAPER; GEOMETRY; WAVEONE; MOLARS;
D O I
10.1016/j.jds.2013.12.002
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background/purpose: The purpose of this study was to compare the canal transportation (CTR) and centering ratio (CR) of Pro File (PF), Twisted File (IF), and Wave One (WO) nickel-titanium instrument systems and evaluate canal volume (CV) and surface area (SA) using micro-computed tomography (CT). Materials and methods: Eighteen extracted human mandibular molars with two separate mesial canals were selected. The specimens were randomly divided into three groups of six teeth. Therefore, twelve root canals were allocated for each group (n = 12): group 1, PF(#30/.06); group 2, TF(#30/.06); group 3, WO (primary) instrument systems. Working lengths were determined 0.5 mm short of the apical foramen. Specimens were scanned before and after root canal preparation. Scanned images were reconstructed and the effects of root canal preparation on the CV and SA were evaluated. Pre- and post-instrumentation cross-sectional images of 1, 3, 5, and 7 mm from the anatomical apex were obtained and the CTR and CR were compared. The data were analyzed by the Kruskal-Wallis test and linear mixed model with Bonferroni's correction. A P < 0.05 was considered to be significant. Results: Postoperative canals were larger and had greater SA, although these changes were not statistically significant (P > 0.05). At any levels (1-, 3-, 5-, and 7-mm), no significant difference was found in the amount of CTR among the groups (P > 0.05). At the 1-, 3-, and 7-mm levels there was no significant difference in the CR among the groups (P > 0.05). However, at the 5-mm level, WO group showed significantly smaller CR than PF group (P < 0.05). Conclusion: Within the limitations of this study, WO showed smaller CR than PF, which imply that careful use of WO in curved canals is recommended. Copyright (C) 2014, Association for Dental Sciences of the Republic of China. Published by Elsevier Taiwan LLC. All rights reserved.
引用
收藏
页码:111 / 117
页数:7
相关论文
共 50 条
  • [21] The abilities of three Nickel-Titanium mechanized systems to negotiate and shape MB2 canals in extracted maxillary first molars-a Micro-Computed Tomographic study
    Ahmed, H. M. A.
    INTERNATIONAL ENDODONTIC JOURNAL, 2019, 52 (11) : 1671 - 1672
  • [23] Effects of Two Nickel-Titanium Instrument Systems, Mtwo versus ProTaper Universal, on Root Canal Geometry Assessed by Micro-Computed Tomography
    Yang, Guobin
    Yuan, Guohua
    Yun, Xiaofei
    Zhou, Xuedong
    Liu, Bojin
    Wu, Hongkun
    JOURNAL OF ENDODONTICS, 2011, 37 (10) : 1412 - 1416
  • [24] In-vitro Assessing the Shaping Ability of Three Nickel-Titanium Rotary Single File Systems by Cone Beam Computed Tomography
    Al-Asadi, Ali Imad
    Al-Hashimi, Raghad
    INTERNATIONAL JOURNAL OF MEDICAL RESEARCH & HEALTH SCIENCES, 2018, 7 (02): : 69 - 74
  • [25] Micro-computed Tomographic Evaluation of Dentinal Microcrack Formation after Using New Heat-treated Nickel-titanium Systems
    Bayram, H. Melike
    Bayram, Emre
    Ocak, Mert
    Uzuner, M. Bora
    Geneci, Ferhat
    Celik, Hakan Hamdi
    JOURNAL OF ENDODONTICS, 2017, 43 (10) : 1736 - 1739
  • [26] Preparation of Oval-shaped Root Canals in Mandibular Molars Using Nickel-Titanium Rotary Instruments: A Micro-computed Tomography Study
    Paque, Frank
    Balmer, Marc
    Attin, Thomas
    Peters, Ove A.
    JOURNAL OF ENDODONTICS, 2010, 36 (04) : 703 - 707
  • [27] Comparative Evaluation of The Shaping Ability of The Three Nickel-Titanium Rotary Instruments Using Cone-Beam Computed Tomography.
    Shumilovich, B. R.
    Adunts, L. M.
    Rostovtsev, V. V.
    Kozhevnikov, V. V.
    Krukova, S. N.
    RESEARCH JOURNAL OF PHARMACEUTICAL BIOLOGICAL AND CHEMICAL SCIENCES, 2018, 9 (01): : 708 - 715
  • [28] A comparison of the shaping abilities of 4 nickel-titanium rotary instruments in simulated root canals
    Yun, HH
    Kim, SK
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 2003, 95 (02): : 228 - 233
  • [29] Shaping ability of non-adaptive and adaptive core nickel-titanium single-file systems with supplementary file in ribbon-shaped canals analysed by micro-computed tomography
    Chinchiyanont, Parichat
    Yanpiset, Kallaya
    Banomyong, Danuchit
    Thongbai-On, Nathamon
    AUSTRALIAN ENDODONTIC JOURNAL, 2023, 49 (01) : 38 - 47
  • [30] Shaping ability of two nickel–titanium instruments activated by continuous rotation or adaptive motion: a micro-computed tomography study
    E. Pedullà
    G. Plotino
    N. M. Grande
    G. Avarotti
    G. Gambarini
    E. Rapisarda
    F. Mannocci