Comparison of the shaping abilities of three nickel-titanium instrumentation systems using micro-computed tomography

被引:5
|
作者
Baek, Jin Yi [1 ]
Yoo, Hyun Mi [1 ]
Park, Dong Sung [1 ]
Oh, Tae Seok [1 ]
Kum, Kee Yeon [2 ,3 ]
Shin, Seung Yun [4 ]
Chang, Seok Woo [5 ]
机构
[1] Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Dept Conservat Dent,Inst Oral Hlth Sci, Seoul, South Korea
[2] Seoul Natl Univ, Sch Dent, Dent Hosp, Dept Conservat Dent,Dent Res Inst, Seoul, South Korea
[3] Seoul Natl Univ, Sch Dent, Program BK21, Dent Hosp, Seoul, South Korea
[4] Kyung Hee Univ, Sch Dent, Dept Periodontol, Seoul 130701, South Korea
[5] Kyung Hee Univ, Sch Dent, Dept Conservat Dent, Seoul 130701, South Korea
基金
新加坡国家研究基金会;
关键词
canal shaping; centering ratio; micro-computed tomography; nickel-titanium instruments; transportation; ROOT-CANAL PREPARATION; SELF-ADJUSTING FILE; ROTARY INSTRUMENTS; TRANSPORTATION; PROTAPER; GEOMETRY; WAVEONE; MOLARS;
D O I
10.1016/j.jds.2013.12.002
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background/purpose: The purpose of this study was to compare the canal transportation (CTR) and centering ratio (CR) of Pro File (PF), Twisted File (IF), and Wave One (WO) nickel-titanium instrument systems and evaluate canal volume (CV) and surface area (SA) using micro-computed tomography (CT). Materials and methods: Eighteen extracted human mandibular molars with two separate mesial canals were selected. The specimens were randomly divided into three groups of six teeth. Therefore, twelve root canals were allocated for each group (n = 12): group 1, PF(#30/.06); group 2, TF(#30/.06); group 3, WO (primary) instrument systems. Working lengths were determined 0.5 mm short of the apical foramen. Specimens were scanned before and after root canal preparation. Scanned images were reconstructed and the effects of root canal preparation on the CV and SA were evaluated. Pre- and post-instrumentation cross-sectional images of 1, 3, 5, and 7 mm from the anatomical apex were obtained and the CTR and CR were compared. The data were analyzed by the Kruskal-Wallis test and linear mixed model with Bonferroni's correction. A P < 0.05 was considered to be significant. Results: Postoperative canals were larger and had greater SA, although these changes were not statistically significant (P > 0.05). At any levels (1-, 3-, 5-, and 7-mm), no significant difference was found in the amount of CTR among the groups (P > 0.05). At the 1-, 3-, and 7-mm levels there was no significant difference in the CR among the groups (P > 0.05). However, at the 5-mm level, WO group showed significantly smaller CR than PF group (P < 0.05). Conclusion: Within the limitations of this study, WO showed smaller CR than PF, which imply that careful use of WO in curved canals is recommended. Copyright (C) 2014, Association for Dental Sciences of the Republic of China. Published by Elsevier Taiwan LLC. All rights reserved.
引用
收藏
页码:111 / 117
页数:7
相关论文
共 50 条
  • [1] Changes in centring and shaping ability using three nickel-titanium instrumentation techniques analysed by micro-computed tomography (μCT)
    Stern, S.
    Patel, S.
    Foschi, F.
    Sherriff, M.
    Mannocci, F.
    INTERNATIONAL ENDODONTIC JOURNAL, 2012, 45 (06) : 514 - 523
  • [2] Shaping Ability of the Conventional Nickel-Titanium and Reciprocating Nickel-Titanium File Systems: A Comparative Study Using Micro-Computed Tomography
    Hwang, Young-Hye
    Bae, Kwang-Shik
    Baek, Seung-Ho
    Kum, Kee-Yeon
    Lee, WooCheol
    Shon, Won-Jun
    Chang, Seok Woo
    JOURNAL OF ENDODONTICS, 2014, 40 (08) : 1186 - 1189
  • [3] Shaping properties and outcomes of nickel-titanium rotary and reciprocation systems using micro-computed tomography: a systematic review
    Nagendrababu, Venkateshbabu
    Ahmed, Hany Mohamed Aly
    QUINTESSENCE INTERNATIONAL, 2019, 50 (03): : 186 - 195
  • [4] A comparison of the shaping ability of three nickel-titanium rotary instruments: a micro-computed tomography study via a contrast radiopaque technique in vitro
    Zhao Wei
    Zhi Cui
    Ping Yan
    Han Jiang
    BMC Oral Health, 17
  • [5] A comparison of the shaping ability of three nickel-titanium rotary instruments: a micro-computed tomography study via a contrast radiopaque technique in vitro
    Wei, Zhao
    Cui, Zhi
    Yan, Ping
    Jiang, Han
    BMC ORAL HEALTH, 2017, 17
  • [6] Comparative evaluation of three nickel-titanium instrumentation systems in human teeth using computed tomography
    Uyanik, M. Ozgur
    Cehreli, Zafer C.
    Mocan, Burce Ozgen
    Dagli, Fugen Tasman
    JOURNAL OF ENDODONTICS, 2006, 32 (07) : 668 - 671
  • [7] Micro-Computed Tomographic Evaluation of 2 Nickel-Titanium Instrument Systems in Shaping Root Canals
    da Silva Limoeiro, Ana Grasiela
    Braitt dos Santos, Antonio Henrique
    De Martin, Alexandre Sigrist
    Kato, Augusto Shoji
    Fontana, Carlos Eduardo
    Gavini, Giulio
    Freire, Laila Gonzales
    da Silveira Bueno, Carlos Eduardo
    JOURNAL OF ENDODONTICS, 2016, 42 (03) : 496 - 499
  • [8] Micro-computed tomography analysis of shaping ability of nickel-titanium instruments activated by continuous rotation or adaptive motion
    Urgupluoglu, Sevde Nur
    Akinci, Levent
    Simsek, Neslihan
    AUSTRALIAN ENDODONTIC JOURNAL, 2024, 50 (02) : 334 - 340
  • [9] A Micro-computed Tomography Evaluation of the Shaping Ability of Two Nickel-titanium Instruments, HyFlex EDM and ProTaper Next
    Venino, Pier Matteo
    Citterio, Claudio Luigi
    Pellegatta, Alberto
    Ciccarelli, Marta
    Maddalone, Marcello
    JOURNAL OF ENDODONTICS, 2017, 43 (04) : 628 - 632
  • [10] Comparison of centring ability and transportation between four nickel titanium instrumentation techniques by micro-computed tomography
    Saberi, N.
    Patel, S.
    Mannocci, F.
    INTERNATIONAL ENDODONTIC JOURNAL, 2017, 50 (06) : 595 - 603