A pulse-echo beamformer with high lateral and temporal resolution and depth-independent lateral response

被引:0
|
作者
Üstüner, KF [1 ]
Bradley, C [1 ]
Thomas, TL [1 ]
机构
[1] Acusona Siemens Co, Mt View, CA 94039 USA
关键词
D O I
暂无
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
With conventional beamformation techniques, in order to increase the depth of field one must sacrifice either lateral or temporal resolution. An increase in the transmit F-number results in an increase in the depth of field at the expense of lateral resolution. The use of multiple transmit/receive events per line, on the other hand, compromises temporal resolution. In this paper we describe a beamformation technique that is not prone to such tradeoffs. The object is insonified with a field that is cosine-modulated laterally, and the rate of growth of the receive aperture is tuned to this lateral modulation frequency. The resultant round-trip lateral bandwidth is optimal: it equals two times the maximum achievable one-way lateral bandwidth. The advantage of this technique is that this full bandwidth is realized at all depths, and with only a single transmit/receive event. A generalization of this technique allows a full frame of full-bandwidth image to be acquired using only two transmit/receive events.
引用
收藏
页码:1559 / 1564
页数:6
相关论文
共 24 条
  • [21] Channel response to a dam-removal sediment pulse captured at high-temporal resolution using routine gage data
    Cashman, Matthew J.
    Gellis, Allen C.
    Boyd, Eric
    Collins, Mathias J.
    Anderson, Scott W.
    McFarland, Brett D.
    Ryan, Ashley M.
    EARTH SURFACE PROCESSES AND LANDFORMS, 2021, 46 (06) : 1145 - 1159
  • [22] Development of a lead-free, high-frequency ultrasound transducer with broad bandwidth and enhanced pulse-echo response, employing β -Ni(OH)2/PVDF-TrFE piezoelectric composite
    Das, Namrata
    Sarkar, Debmalya
    Yadav, Nitin
    Ali, Asfak
    Das, Sukhen
    Ray, Partha Pratim
    Hoque, Nur Amin
    CHEMICAL ENGINEERING JOURNAL, 2023, 475
  • [23] T2 mapping of the heart with high temporal and spatial resolution using a radial double inversion fast spin-echo pulse sequence with view sharing
    Maria Altbach
    Tomoe Barr
    Jaspreet Singh
    Bujji Ainapurapu
    Dipak Kc
    Scott Squire
    Jean-Philippe Galons
    Chuan Huang
    Aiden Abidov
    Journal of Cardiovascular Magnetic Resonance, 14 (Suppl 1)
  • [24] Ultrafast in-line interactive m-mode tool for quantification of left-ventricular (LV) septo-lateral wall motion (SLWM) from high-temporal resolution (6-12ms) cardiac cine steady-state free precession (SSFP) images
    Amol Pednekar
    Claudio Arena
    Janie Swaab
    Benjamin Cheong
    Raja Muthupillai
    Journal of Cardiovascular Magnetic Resonance, 13 (Suppl 1)