Learning curve in circular multipolar phased radiofrequency ablation of atrial fibrillation

被引:5
|
作者
Martirosyan, Mihran [1 ]
Kiss, Alexandra [1 ]
Nagy-Balo, Edina [1 ]
Sandorfi, Gabor [1 ]
Tint, Diana [1 ]
Edes, Istvan [1 ]
Csanadi, Zoltan [1 ]
机构
[1] Univ Debrecen, Inst Cardiol, H-4032 Debrecen, Hungary
关键词
atrial fibrillation; phased radiofrequency ablation; learning curve; arrhythmia-free survival; PULMONARY VEIN ISOLATION; CATHETER ABLATION; MULTIELECTRODE CATHETER; CRYOBALLOON ABLATION; FOLLOW-UP; EFFICACY; SAFETY; COMPLICATIONS;
D O I
10.5603/CJ.a2014.0085
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Although atrial fibrillation (AF) ablation is considered a technically challenging procedure, studies on the learning curve of different pulmonary vein isolation (PVI) techniques are limited. We investigated the time-dependent changes in procedural parameters, complication rates, and in the 1-year clinical outcome during our initial experience with circular multipolar phased radiofrequency (RF) ablation. Methods and results: The first 132 consecutive patients (40 female; age: 56.6 +/- 10.4 years) who underwent PVI with phased RF ablation for paroxysmal or persistent AF at our center were included in the study. Procedural parameters and atrial arrhythmia-free survival were compared in the first, second and third group of 44 successive patients. All pulmonary veins were successfully isolated in 44 (100%), 41 (93.8%) and 42 (95.5%) patients in Tierce 1, 2 and 3, respectively (p = 0.233). The number of RF applications (per vein) required for isolation and fluoroscopy times demonstrated a significant decrease with experience, and a trend towards lower procedure times in Tierces 2 and 3 was also observed. Atrial arrhythmia-free survival rates at 12 months postablation were 68.18%, 75%, and 70.75% in Tierce 1, Tierce 2 and Tierce 3, respectively (p = 0.772). Pericardial tamponade requiring percutaneous subxiphoid drainage occurred in 1 patient (Tierce 3) as the only significant procedural complication. Conclusions: A learning curve effect was demonstrated in fluoroscopy times and in the number of RF applications but not in the acute success and in the long-term arrhythmia-free survival with circular multipolar RF ablations.
引用
收藏
页码:260 / 266
页数:7
相关论文
共 50 条
  • [21] Multipolar ablation for atrial fibrillation: are we going in circles?
    Verma, Atul
    EUROPACE, 2016, 18 (05): : 631 - 632
  • [22] SIMULTANEOUS MAPPING AND RADIOFREQUENCY ABLATION OF PAROXYSMAL ATRIAL FIBRILLATION USING HIGH-DENSITY MULTIPOLAR CATHETER
    Vieira, M. S.
    Vieira, P.
    Roque, C.
    Sa, I.
    Palma, P.
    Antunes, N.
    Meireles, A.
    Gomes, C.
    Anjo, D.
    Santos, M.
    Dias, V.
    Carvalho, H.
    Torres, S.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2011, 22 : S111 - S111
  • [23] Cryoballoon ablation versus radiofrequency ablation for atrial fibrillation
    Reissmann, Bruno
    Metzner, Andreas
    Kuck, Karl-Heinz
    TRENDS IN CARDIOVASCULAR MEDICINE, 2017, 27 (04) : 271 - 277
  • [24] Phased RF ablation in persistent atrial fibrillation
    Hummel, John
    Michaud, Gregory
    Hoyt, Robert
    DeLurgio, David
    Rasekh, Abdi
    Kusumoto, Fred
    Giudici, Michael
    Dan, Dan
    Tschopp, David
    Calkins, Hugh
    Boersma, Lucas
    HEART RHYTHM, 2014, 11 (02) : 202 - 209
  • [25] Radiofrequency catheter ablation in atrial flutter and atrial fibrillation
    Reithmann, C
    Hoffmann, E
    Steinbeck, G
    HERZ, 1998, 23 (04) : 209 - 218
  • [26] Radiofrequency ablation of atrial fibrillation: comparison of success rate of circular ablation vs point-by-point ablation with contact force in paroxysmal and persistent atrial fibrillation
    Rosso, R.
    Levi, Y. L.
    Viskin, S. V.
    EUROPEAN HEART JOURNAL, 2015, 36 : 740 - 740
  • [27] Multicenter Prospective Study Comparing Phased Multipolar versus Traditional Radiofrequency Ablation
    Azizi, Zahra
    Verma, Atul
    Alipour, Pouria
    Khaykin, Yaariv
    Leong-Sit, Peter
    Sarrazin, Jean-Francois
    Sturmer, Marcio
    Patterson, Sherri
    Morillo, Carlos
    Amit, Guy
    Roux, Jean-Francois
    Essebag, Vidal
    CIRCULATION, 2017, 136
  • [28] Learning curve for ablation of atrial fibrillation in medium-volume centers
    Sairaku, Akinori
    Nakano, Yukiko
    Oda, Noboru
    Makita, Yuko
    Kajihara, Kenta
    Tokuyama, Takehito
    Kihara, Yasuki
    JOURNAL OF CARDIOLOGY, 2011, 57 (03) : 263 - 268
  • [29] Single ring isolation for atrial fibrillation ablation: Impact of the learning curve
    Thiyagarajah, Anand
    Mahajan, Rajiv
    Iwai, Shinsuke
    Gupta, Aashray
    Linz, Dominik
    Chim, Ivana
    Emami, Mehrdad
    Kadhim, Kadhim
    O'Shea, Catherine
    Middeldorp, Melissa E.
    Lau, Dennis H.
    Sanders, Prashanthan
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2022, 33 (04) : 608 - 617
  • [30] Surgical ablation of atrial fibrillation using radiofrequency
    Breda, Joao Roberto
    Castaldi Ragognetti Breda, Ana Silvia
    Meneguini, Adriano
    Oliveira Freitas, Andrea Cristina
    Pires, Adilson Casemiro
    REVISTA BRASILEIRA DE CIRURGIA CARDIOVASCULAR, 2008, 23 (01): : 118 - 122