High-Throughput Liquid-Liquid Extraction in 96-Well Format: Parallel Artificial Liquid Membrane Extraction

被引:0
|
作者
Gjelstad, Astrid [1 ]
Andresen, Alf Terje [2 ]
Dahlgren, Anders [3 ]
Gundersen, Thomas E. [4 ]
Pedersen-Bjergaard, Stig [1 ,5 ]
机构
[1] Univ Oslo, Sch Pharm, Oslo, Norway
[2] Vitas Analyt Serv Ltd, Oslo, Norway
[3] CTO Vitas, Oslo, Norway
[4] CRO Vitas Analyt Serv Ltd, Oslo, Norway
[5] Univ Copenhagen, Dept Pharm, Copenhagen, Denmark
关键词
MICROEXTRACTION TECHNIQUES; SOLVENT-MICROEXTRACTION; ANALYTICAL-CHEMISTRY; HUMAN PLASMA;
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Parallel artificial liquid membrane extraction (PALME) is a miniaturized version of liquid-liquid extraction (LLE) and is based on two 96-well plates in a sandwich-like configuration. With a very simple workflow, 96 samples can be processed simultaneously in PALME, providing analyte enrichment, highly efficient sample cleanup, and direct compatibility with liquid chromatography-mass spectrometry (LC-MS). The consumption of hazardous organic solvents is also almost eliminated using PALME as the sample preparation technique. This article summarizes current experiences with PALME, based on work both in a university laboratory and in an analytical services contract laboratory.
引用
收藏
页码:192 / 196
页数:5
相关论文
共 50 条
  • [1] High-Throughput Liquid-Liquid Extraction in 96-Well Format: Parallel Artificial Liquid Membrane Extraction
    Gjelstad, Astrid
    Andresen, Alf Terje
    Dahlgren, Anders
    Gundersen, Thomas E.
    Pedersen-Bjergaard, Stig
    LC GC EUROPE, 2017, 30 (01) : 10 - 17
  • [2] Parallel artificial liquid membrane extraction: micro-scale liquid-liquid-liquid extraction in the 96-well format
    Gjelstad, Astrid
    Rasmussen, Knut Einar
    Parmer, Marthe Petrine
    Pedersen-Bjergaard, Stig
    BIOANALYSIS, 2013, 5 (11) : 1377 - 1385
  • [3] High-Throughput Determination of Sodium Danshensu in Beagle Dogs by the LCMS/MS Method, Employing Liquid-Liquid Extraction Based on 96-Well Format Plates
    Jiang, Jingjing
    Zhao, Xin
    Li, Xiuxiu
    Wu, Shengyuan
    Yu, Shidan
    Lou, Yuefen
    Fan, Guorong
    MOLECULES, 2017, 22 (05):
  • [4] An improved high-throughput liquid chromatographic/tandem mass spectrometric method for terbinafine quantification in human plasma, using automated liquid-liquid extraction based on 96-well format plates
    Dotsikas, Yannis
    Apostolou, Constantinos
    Kousoulos, Constantinos
    Tsatsou, Georgia
    Loukas, Yannis L.
    BIOMEDICAL CHROMATOGRAPHY, 2007, 21 (02) : 201 - 208
  • [5] Comparison of plasma sample purification by manual liquid-liquid extraction, automated 96-well liquid-liquid extraction and automated 96-well solid-phase extraction for analysis by highperformance liquid chromatography with tandem mass spectrometry
    Jemal, M
    Teitz, D
    Ouyang, Z
    Khan, S
    JOURNAL OF CHROMATOGRAPHY B, 1999, 732 (02): : 501 - 508
  • [6] Nanoliter Scale Parallel Liquid-Liquid Extraction for High-Throughput Purification on a Droplet Microarray
    Wiedmann, Janne J.
    Demirdoegen, Yelda N.
    Schmidt, Stefan
    Kuzina, Mariia A.
    Wu, Yanchen
    Wang, Fei
    Nestler, Britta
    Hopf, Carsten
    Levkin, Pavel A.
    SMALL, 2023, 19 (09)
  • [7] A rubber transfer gasket to improve the throughput of liquid-liquid extraction in 96-well plates: Application to vitamin D testing
    Hoofnagle, Andrew N.
    Laha, Thomas J.
    Donaldson, Thomas F.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (19): : 1639 - 1642
  • [8] DETERMINATION OF D-AMPHETAMINE AND DIPHENHYDRAMINE IN DOG PLASMA BY A 96-WELL FORMAT LIQUID-LIQUID EXTRACTION AND CAPILLARY ZONE ELECTROPHORESIS
    Li, Ji
    Zhong, Dafang
    Zhang, Lingli
    Pan, Yaju
    Fan, Guorong
    Wu, Yutian
    DRUG METABOLISM REVIEWS, 2008, 40 : 49 - 49
  • [9] Parallel electromembrane extraction in the 96-well format
    Eibak, Lars Erik Eng
    Rasmussen, Knut Einar
    Oiestad, Elisabeth Leere
    Pedersen-Bjergaard, Stig
    Gjelstad, Astrid
    ANALYTICA CHIMICA ACTA, 2014, 828 : 46 - 52
  • [10] Semi-automated 96-well liquid-liquid extraction for quantitation of drugs in biological fluids
    Zhang, NY
    Hoffman, KL
    Li, WL
    Rossi, DT
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2000, 22 (01) : 131 - 138