Photoplethysmography beyond Perfusion and Oxygenation Monitoring: Pulse Wave Analysis for Hepatic Graft Monitoring

被引:0
|
作者
Akl, Tony J. [1 ]
Wilson, Mark A. [2 ,3 ]
Ericson, M. Nance [4 ]
Cote, Gerard L. [1 ]
机构
[1] Texas A&M Univ, Dept Biomed Engn, College Stn, TX 77843 USA
[2] Univ Pittsburgh, Dept Surg, Pittsburgh, PA USA
[3] VA Pittsburgh Healthcare Syst, Pittsburgh, PA USA
[4] Oak Ridge Natl Lab, Oak Ridge, TN USA
来源
OPTICAL DIAGNOSTICS AND SENSING XIV: TOWARD POINT-OF-CARE DIAGNOSTICS | 2014年 / 8951卷
关键词
Photoplethysmography; Pulse waveform; Pulse analysis; Compliance; Graft monitoring; IMPLANTABLE SENSOR; CONTOUR ANALYSIS; LIVER; MICROCIRCULATION; QUANTIFICATION; ELASTOGRAPHY; FIBROSIS;
D O I
10.1117/12.2039611
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Photoplethysmography is a technique widely used in monitoring perfusion and blood oxygen saturation based on the amplitude of the pulsatile signal at one or multiple wavelengths. However, the pulsatile signal carries in its waveform a substantial amount of information about the mechanical properties of the tissue and vasculature under investigation that is still yet to be utilized to its full potential. In this work, we present the feasibility of pulse wave analysis for the application of monitoring hepatic implants and diagnosing graft complications. In particular, we demonstrate the utility of computing the slope of the pulse during the diastole phase to assess compliance changes in tissue. This hypothesis was tested in a series of in vitro experiments using a polydimethylsiloxane based phantom mimicking the optical and mechanical properties of the portal vein. The emptying time decreased from 148.1 ms for phantoms with compliance of 12 KPa to 97.5 ms for phantoms with compliance of 61 KPa. These compliance levels mimic those seen for normal and fibrotic hepatic tissue respectively.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Imaging Photoplethysmography as a Reliable Tool for Monitoring Tissue Perfusion during Open Brain and Abdominal Surgeries
    Kamshilin A.A.
    Bulletin of the Russian Academy of Sciences: Physics, 2022, 86 (Suppl 1) : S85 - S91
  • [32] Continuous intraoperative perfusion monitoring of free microvascular anastomosed fasciocutaneous flaps using remote photoplethysmography
    Sebastian P. Schraven
    Benjamin Kossack
    Daniel Strüder
    Maximillian Jung
    Lotte Skopnik
    Justus Gross
    Anna Hilsmann
    Peter Eisert
    Robert Mlynski
    Eric L. Wisotzky
    Scientific Reports, 13 (1)
  • [33] A pulse wave monitoring system based on a respiratory pacemaker
    Kameda Y.
    Kashihara K.
    Kashihara, Koji (kojikasi@is.tokushima-u.ac.jp), 1600, Springer Verlag (06):
  • [34] Textile Triboelectric Nanogenerators for Wearable Pulse Wave Monitoring
    Chen, Guorui
    Au, Christian
    Chen, Jun
    TRENDS IN BIOTECHNOLOGY, 2021, 39 (10) : 1078 - 1092
  • [35] Ambulatory Pulse Wave Velocity Monitoring A Step Forward
    Papaioannou, Theodore G.
    Vrachatis, Dimitrios A.
    Tousoulis, Dimitris
    HYPERTENSION, 2017, 70 (01) : 27 - 29
  • [36] Non-invasive intracranial pulse wave monitoring
    Ragauskas, Arminas
    Daubaris, Gediminas
    Petkus, Vytautas
    Chomskis, Romanas
    Raisutis, Renaldas
    Deksnys, Vytautas
    Guzaitis, Jonas
    Lengvinas, Gintautas
    Matijosaitis, Vaidas
    INFORMATICA, 2008, 19 (03) : 391 - 402
  • [37] Pulse wave transit time for monitoring respiration rate
    Johansson, A.
    Ahlstrom, C.
    Lanne, T.
    Ask, P.
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2006, 44 (06) : 471 - 478
  • [38] Pulse wave transit time for monitoring respiration rate
    A. Johansson
    C. Ahlstrom
    T. Lanne
    P. Ask
    Medical and Biological Engineering and Computing, 2006, 44 : 471 - 478
  • [39] Cerebral oxygenation monitoring for total arch replacement using selective cerebral perfusion
    Yamashita, K
    Kazui, T
    Terada, H
    Washiyama, N
    Suzuki, K
    Bashar, AHM
    ANNALS OF THORACIC SURGERY, 2001, 72 (02): : 503 - 508
  • [40] In vivo performance of a visible wavelength optical sensor for monitoring intestinal perfusion and oxygenation
    Robinson, Mitchell B.
    Wisniowiecki, Anna M.
    Butcher, Ryan J.
    Wilson, Mark A.
    Ericson, M. Nance
    Cote, Gerard L.
    JOURNAL OF BIOMEDICAL OPTICS, 2018, 23 (05)