Photoplethysmography beyond Perfusion and Oxygenation Monitoring: Pulse Wave Analysis for Hepatic Graft Monitoring

被引:0
|
作者
Akl, Tony J. [1 ]
Wilson, Mark A. [2 ,3 ]
Ericson, M. Nance [4 ]
Cote, Gerard L. [1 ]
机构
[1] Texas A&M Univ, Dept Biomed Engn, College Stn, TX 77843 USA
[2] Univ Pittsburgh, Dept Surg, Pittsburgh, PA USA
[3] VA Pittsburgh Healthcare Syst, Pittsburgh, PA USA
[4] Oak Ridge Natl Lab, Oak Ridge, TN USA
关键词
Photoplethysmography; Pulse waveform; Pulse analysis; Compliance; Graft monitoring; IMPLANTABLE SENSOR; CONTOUR ANALYSIS; LIVER; MICROCIRCULATION; QUANTIFICATION; ELASTOGRAPHY; FIBROSIS;
D O I
10.1117/12.2039611
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Photoplethysmography is a technique widely used in monitoring perfusion and blood oxygen saturation based on the amplitude of the pulsatile signal at one or multiple wavelengths. However, the pulsatile signal carries in its waveform a substantial amount of information about the mechanical properties of the tissue and vasculature under investigation that is still yet to be utilized to its full potential. In this work, we present the feasibility of pulse wave analysis for the application of monitoring hepatic implants and diagnosing graft complications. In particular, we demonstrate the utility of computing the slope of the pulse during the diastole phase to assess compliance changes in tissue. This hypothesis was tested in a series of in vitro experiments using a polydimethylsiloxane based phantom mimicking the optical and mechanical properties of the portal vein. The emptying time decreased from 148.1 ms for phantoms with compliance of 12 KPa to 97.5 ms for phantoms with compliance of 61 KPa. These compliance levels mimic those seen for normal and fibrotic hepatic tissue respectively.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Intestinal perfusion monitoring using photoplethysmography
    Akl, Tony J.
    Wilson, Mark A.
    Ericson, M. Nance
    Cote, Gerard L.
    JOURNAL OF BIOMEDICAL OPTICS, 2013, 18 (08)
  • [2] PERFUSION MONITORING BY CONTACTLESS PHOTOPLETHYSMOGRAPHY IMAGING
    Lai, Marco
    Shan, Caifeng
    Ciuhu-Pijlman, Calina
    Izamis, Maria-Louisa
    2019 IEEE 16TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI 2019), 2019, : 1778 - 1782
  • [3] Preface Monitoring Tissue Perfusion and Oxygenation
    Hamlin, Shannan K.
    Parmley, C. Lee
    CRITICAL CARE NURSING CLINICS OF NORTH AMERICA, 2014, 26 (03) : IX - X
  • [4] Reflectance Photoplethysmography as Noninvasive Monitoring of Tissue Blood Perfusion
    Abay, Tomas Ysehak
    Kyriacou, Panayiotis A.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2015, 62 (09) : 2187 - 2195
  • [5] MONITORING PERFUSION IN PULSE OXIMETRY
    GRIGG, KN
    ANAESTHESIA AND INTENSIVE CARE, 1988, 16 (03) : 377 - 378
  • [6] Wearable System Integrating Dual Piezoresistive and Photoplethysmography Sensors for Simultaneous Pulse Wave Monitoring
    Jafarizadeh, Borzooye
    Chowdhury, Azmal Huda
    Sozal, Md Shariful Islam
    Cheng, Zhe
    Pala, Nezih
    Wang, Chunlei
    ACS APPLIED MATERIALS & INTERFACES, 2024, 16 (47) : 65402 - 65413
  • [7] Analyzing the value of monitoring duodenal mucosal perfusion using photoplethysmography
    Mitchell P Fink
    Critical Care, 18
  • [8] Analyzing the value of monitoring duodenal mucosal perfusion using photoplethysmography
    Fink, Mitchell P.
    CRITICAL CARE, 2014, 18 (05):
  • [9] Remote photoplethysmography for skin perfusion monitoring using narrowband illumination
    Marcinkevics, Z.
    Rubins, U.
    Aglinska, A.
    Caica, A.
    Grabovskis, A.
    CLINICAL AND PRECLINICAL OPTICAL DIAGNOSTICS II, 2019, 11073
  • [10] Monitoring cardiac function: Echocardiography, pulse contour analysis and beyond
    Renner, Jochen
    Scholz, Jens
    Bein, Berthold
    BEST PRACTICE & RESEARCH-CLINICAL ANAESTHESIOLOGY, 2013, 27 (02) : 187 - 200