Impact of Position of Fault Current Limiter on the Interrupting of Circuit Breaker

被引:0
|
作者
Li, Weiwei [1 ]
Dan, Shuheng [1 ]
Li, Yan [1 ]
机构
[1] Shanghai Univ Elect Power, Elect Power & Automat Engn Dept, Shanghai, Peoples R China
关键词
transient recovery voltage; FCL; Rate of rise of recovery voltage; circuit breaker; source-side voltage of FCL;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The fault current limiter (FCL) can be installed upstream and downstream from the circuit breaker. With regards to short-line fault in power transmission lines installed with FCL under different current limiting riot, the impact of the installation position of FCL on transient recovery voltage and the rate of rise of recovery voltage (RRRV) were studied. The presence of the FCL reduces recovery voltage, regardless of the installation position of FCL were upstream or downstream from the circuit breaker. Whereas the different installation position of FCL have no impact on the RRRV of circuit breaker. Comparing the voltage at the source-side terminal of FCL under different position of FCL, the voltage was relatively low when FCL is installed downstream from the circuit breaker. In other words, the best installation position of FCL is downstream form the circuit breaker.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] A Self-Charging Artificial Current Zero DC Circuit Breaker Based on Superconducting Fault Current Limiter
    Yang, Kun
    Ge, Hanming
    Wang, Xian
    Liu, Zhiyuan
    Geng, Yingsan
    Wang, Jianhua
    [J]. IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2019, 29 (02)
  • [22] Impact on Current-Interrupting Characteristic by Parameter Settings of Superconducting Hybrid DC Circuit Breaker
    Choi, Sang-Jae
    Lim, Sung-Hun
    [J]. ENERGIES, 2021, 14 (09)
  • [23] Parameters Selection Method of Circuit Breaker and Fault Current Limiter in Mesh-Type DC Microgrid
    Kong, Liang
    Nian, Heng
    [J]. IEEE ACCESS, 2021, 9 : 35514 - 35523
  • [24] Coupled Inductor Bidirectional Fault Current Limiter and Its Joint Operation Strategy With DC Circuit Breaker
    Wang, Zhenhao
    Wang, Wei
    Hou, Zhaojing
    Cheng, Long
    Wang, Yanxu
    Li, Guoqing
    [J]. Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2022, 42 (07): : 2520 - 2531
  • [25] Theoretical expression of rate of rise of recovery voltage across a circuit breaker connected with fault current limiter
    Calixte, E
    Yokomizu, Y
    Shimizu, H
    Matsumura, T
    [J]. ELECTRIC POWER SYSTEMS RESEARCH, 2005, 75 (01) : 1 - 8
  • [26] Parameter optimization design method for a fast-switch-based fault current limiter and circuit breaker
    Chen, Xinquan
    Liang, Yuansheng
    Wang, Gang
    Li, Haifeng
    [J]. INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2020, 114
  • [27] SF6passive resonance DC circuit breaker combined with a superconducting fault current limiter
    Xiang, Bin
    Cheng, Nuo
    Yang, Kun
    Liu, Zhiyuan
    Geng, Yingsan
    Wang, Jianhua
    Yanabu, Satoru
    [J]. IET GENERATION TRANSMISSION & DISTRIBUTION, 2020, 14 (14) : 2869 - 2878
  • [28] Resistive Superconducting Fault Current Limiter - Integrated Bidirectional Hybrid DC Circuit Breaker for HVDC Systems
    Reddy, Siddavatam Ravi Prakash
    Rajashekara, Kaushik
    Krishnamoorthy, Harish Sarma
    [J]. 2022 INTERNATIONAL POWER ELECTRONICS CONFERENCE (IPEC-HIMEJI 2022- ECCE ASIA), 2022, : 2004 - 2008
  • [29] Circuit breaker interrupting capacity and short-time current ratings
    Roybal, DD
    [J]. CONFERENCE RECORD OF THE 2004 ANNUAL PULP AND PAPER INDUSTRY TECHNICAL CONFERENCE, 2004, : 130 - 134
  • [30] Improvement of DC Fault Current Limiting and Interrupting Operation of Hybrid DC Circuit Breaker Using Double Quench
    Choi, Sang-Jae
    Lee, Jun-Hyup
    Lee, Jin-Wook
    Lim, Sung-Hun
    [J]. ENERGIES, 2021, 14 (14)