In vitro visual and visible light transillumination methods for detection of natural non-cavitated approximal caries

被引:10
|
作者
Abogazalah, N. [1 ,2 ]
Eckert, G. J. [3 ]
Ando, Masatoshi [1 ]
机构
[1] Indiana Univ, Sch Dent, Dept Cariol Operat Dent & Dent Publ Hlth, 415 Lansing St, Indianapolis, IN 46202 USA
[2] King Khalid Univ, Coll Dent, Dept Restorat Dent Sci, Abha, Saudi Arabia
[3] Indiana Univ Sch Med, Dept Biostat, Indianapolis, IN 46202 USA
关键词
Approximal caries; Caries detection; Visible light transillumination; International caries detection and assessment system (ICDAS); Non-cavitated caries lesion; Imaging geometry; Digital imaging transillumination; DIFOTI; DENTAL-CARIES; PERFORMANCE; REPRODUCIBILITY; DIAGNOSIS; ACCURACY; DEVICE; IMAGES; ICDAS;
D O I
10.1007/s00784-018-2546-3
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
ObjectivesThe objective was to evaluate a visible-light-transillumination (using Digital Imaging Fiber-Optic Transillumination machine: DIFOTI) method using occlusal view (DIFOTI-occl), axial view (buccal and lingual: DIFOTI-axial), and combination of all views (DIFOTI-all) for detecting non-cavitated approximal caries and to compare its performance to visual examination (International Caries Detection and Assessment System: ICDAS).Materials and methodsThirty extracted human premolars were selected (sound to lesions into the outer one-third of the dentine) based on micro-computed tomography (-CT). Teeth were mounted in a custom-made device to simulate approximal contact. DIFOTI (Electro-Optical Sciences Inc., Irvington, NY, USA) images were obtained from the occlusal, buccal, and lingual views. DIFOTI image and ICDAS examinations were performed and repeated by three trained/calibrated examiners. Sensitivity, specificity, area under receiver operating characteristics curve (A(z)), inter- and intra-class correlation coefficients (ICCs), and correlation were determined.ResultsSensitivity/specificity was for DIFOTI-occl: 0.42/0.75, DIFOTI-axial: 0.86/0.93, DIFOTI-all: 0.91/0.69, and for ICDAS: 0.89/0.83. A(z) for DIFOTI-occl was significantly lower than that of DIFOTI-axial (p<0.001), DIFOTI-all (p=0.002), and ICDAS (p=0.005). Spearman correlation coefficients with -CT for DIFOTI-occl (r=0.39) showed weak association, while DIFOTI-axial (r=0.80), DIFOTI-all (r=0.91), and ICDAS (r=0.90) showed moderate association. ICCs for intra-examiner repeatability/inter-examiner agreement were for DIFOTI-occl (0.64/0.58), DIFOTI-axial (0.92/0.89), DIFOTI-all (0.85/0.83), and ICDAS (0.79/0.72).ConclusionsThe results of the current in vitro study suggest that, for detection of non-cavitated approximal caries lesions, DIFOTI performs better using axial than occlusal view.Clinical relevanceApproximal non-cavitated caries detection is challenging. DIFOTI can observe images from occlusal-, buccal-, and lingual views. DIFOTI and visual (ICDAS) examinations of buccal- and lingual- and all-views are more suitable than those of occlusal view for a detection of non-cavitated approximal caries.
引用
收藏
页码:1287 / 1294
页数:8
相关论文
共 44 条
  • [41] In vitro Detection of Occlusal Caries on Permanent Teeth by a Visual, Light-Induced Fluorescence and Photothermal Radiometry and Modulated Luminescence Methods
    Jallad, Mahmoud
    Zero, Domenick
    Eckert, George
    Zandona, Andrea Ferreira
    CARIES RESEARCH, 2015, 49 (05) : 523 - 530
  • [42] Occlusal Caries Detection and Diagnosis Using Visual ICDAS Criteria, Laser Fluorescence Measurements, and Near-Infrared Light Transillumination Images
    Tassoker, Melek
    Ozcan, Sevgi
    Karabekiroglu, Said
    MEDICAL PRINCIPLES AND PRACTICE, 2020, 29 (01) : 25 - 31
  • [43] The Reliability and Accuracy of Two Methods for Proximal Caries Detection and Depth on Directly Visible Proximal Surfaces: An in vitro Study
    Ekstrand, K. R.
    Luna, L. E.
    Promisiero, L.
    Cortes, A.
    Cuevas, S.
    Reyes, J. F.
    Torres, C. E.
    Martignon, S.
    CARIES RESEARCH, 2011, 45 (02) : 93 - 99
  • [44] EVALUATION OF METHODS TO ASSESS TERMINATION RATES OF COVER CROPS USING VISUAL AND NON-VISIBLE LIGHT ACTIVE SENSORS
    Kornecki, T. S.
    Arriaga, F. J.
    Price, A. J.
    TRANSACTIONS OF THE ASABE, 2012, 55 (03) : 733 - 741