Rapid and sensitive detection of biological warfare agents using time-resolved fluorescence assays

被引:147
|
作者
Peruski, AH [1 ]
Johnson, LH [1 ]
Peruski, LF [1 ]
机构
[1] Naval Med Res Ctr, Biol Def Res Directorate, Silver Spring, MD USA
关键词
ELISA; immunological assay; time-resolved fluorescence assay; lanthanide; infectious disease; biological weapons;
D O I
10.1016/S0022-1759(02)00030-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We have achieved sensitive, rapid and reproducible detection of three biological threat agents in a variety of biological and environmental matrices using the DELFIA time-resolved fluorometry (TRF) assay system (Perkin-Elmer Life Sciences, Akron, OH). Existing ELISA assays for the detection of Francisella tularensis, Clostridium botulinum A/B neurotoxin (BotNT A/B), and Staphylococcus aureus enterotoxin B (SEB) were converted to TRY assays. They use 100 mul of positive control or unknown per test well and require just over 2 h to run, Fluorescent signal read time is a fraction of a second per well. The assay format consists of a capture ELISA utilizing a biotinylated capture antibody, prebound to a streptavidin-coated 96-well plate and a lanthanide (Europium, Eu3+)-labeled detector antibody. The bound Eu-labeled detector antibody produces a fluorescent signal upon the addition of an enhancement solution. The signal results from the dissociation of the Europium from the antibody, creating a micelle, thus amplifying the signal nearly one million-fold. Sensitivities achieved by these assays were between 4 and 20 pg/ml in buffer. Additionally, we have tested this system in different matrices such as serum, urine, dirt, and sewage. Concentration curves generated from standard solutions produced a wide linear range making serial dilutions of unknown samples unnecessary. DELFIA TRF assays are significantly better in terms of sensitivity, linear range, and run time than standard capture ELISAs and should facilitate early detection of potential biological warfare agents in clinical and environmental samples. (C) 2002 Elsevier Science B.V All rights reserved.
引用
收藏
页码:35 / 41
页数:7
相关论文
共 50 条
  • [31] Highly sensitive chromatographic time-resolved fluoroimmunoassay for rapid onsite detection of streptomycin in milk
    Wang, Zile
    Sun, Yuanze
    Liang, Demei
    Zeng, Yuyang
    He, Shuang
    Mari, Ghulam Mujtaba
    Peng, Tao
    Jiang, Haiyang
    JOURNAL OF DAIRY SCIENCE, 2020, 103 (10) : 8750 - 8760
  • [32] Rapid and sensitive HBsAg immunoassay based on fluorescent nanoparticle labels and time-resolved detection
    Valanne, A
    Huopalahti, S
    Vainionpää, R
    Härmä, H
    Lovgren, T
    JOURNAL OF VIROLOGICAL METHODS, 2005, 129 (01) : 83 - 90
  • [33] Spectra-resolved technique of a sensitive time-resolved fluorescence immunoassay instrument
    Guo, ZY
    Tian, Z
    Jia, YL
    ALT'03 INTERNATIONAL CONFERENCE ON ADVANCED LASER TECHNOLOGIES: BIOMEDICAL OPTICS, 2003, 5486 : 222 - 226
  • [34] Cucurbiturils: Molecular nanocapsules for time-resolved fluorescence-based assays
    Marquez, C
    Huang, F
    Nau, WM
    IEEE TRANSACTIONS ON NANOBIOSCIENCE, 2004, 3 (01) : 39 - 45
  • [35] HCEA ASSAY USING TIME-RESOLVED FLUORESCENCE
    LEIVO, P
    PETTERSSON, K
    SCANDINAVIAN JOURNAL OF IMMUNOLOGY, 1986, 24 (04) : 468 - 468
  • [36] Time-resolved fluorescence detection of mosaic DNA chip
    Zhuzhou Institute of Technology, Zhuzhou 412008, China
    不详
    不详
    不详
    不详
    J. Nanosci. Nanotechnol., 2006, 1 (66-71):
  • [37] Time-resolved fluorescence detection of mosaic DNA chip
    He, QG
    Chen, H
    Nie, LB
    Tang, JX
    Xiao, PF
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2006, 6 (01) : 66 - 71
  • [38] A homogeneous time-resolved fluorescence detection of telomerase activity
    Gabourdes, M
    Bourgine, V
    Mathis, G
    Bazin, H
    Alpha-Bazin, W
    ANALYTICAL BIOCHEMISTRY, 2004, 333 (01) : 105 - 113
  • [39] Active CMOS biochip for time-resolved fluorescence detection
    Patounakis, G
    Shepard, KL
    Levicky, R
    2005 SYMPOSIUM ON VLSI CIRCUITS, DIGEST OF TECHNICAL PAPERS, 2005, : 68 - 71
  • [40] TIME-RESOLVED FLUORESCENCE DETECTION OF HCV PCR PRODUCTS
    HAYASHI, PH
    ZELDIS, JB
    VANDENBRINK, KM
    SHERMAN, DG
    GODSEY, JH
    HEPATOLOGY, 1992, 16 (04) : A205 - A205