A comparison of subdermal wire electrodes with collodion-applied disk electrodes in long-term EEG recordings in ICU

被引:33
|
作者
Young, G. Bryan
Ives, John R.
Chapman, Martin G.
Mirsattari, Seyed M.
机构
[1] Univ Western Ontario, Univ Hosp, Dept Clin Neurol Sci, London, ON N6A 5A5, Canada
[2] Univ Toronto, Toronto, ON, Canada
关键词
EEG; electrodes; subdermal wire; disk; artifact; cEEG; LTM;
D O I
10.1016/j.clinph.2006.02.006
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: To compare long-term electroencephalographic (EEG) recordings of standard collodion-applied scalp disk electrodes (SDEs) with newly developed subdermal wire electrodes (SWEs) in comatose intensive care unit (ICU) patients. Methods: Ten comatose ICU patients had simultaneous recordings from 8 active SDEs and 8 active SVV'E for > 24 h. The timing and number of 60 Hz and other electrode artifacts were compared for each set of electrodes by an EEGer who read the recordings in a blinded manner. Results: Sixty Hertz artifact was seen in 16 of 80 SDE and one of 80 SWEs within the first 6 h (P = 0.0002). Large, persistent artifacts occurred in 30/80 SDE and 8 of 80 SWE (P=0.0001). Motion artifact with chest physiotherapy was more common in SWEs. Conclusions: SWE are less susceptible to artifacts and are more suitable for the long-term EEG monitoring in ICU. Significance: This is the first controlled study that demonstrates the superiority of SWEs compared to SDEs in an ICU population. (c) 2006 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:1376 / 1379
页数:4
相关论文
共 27 条
  • [21] VENTRICULAR PACING WITH EPIGASTRIC TRANSDIAPHRAGMATIC ELECTRODES - LONG-TERM FOLLOW-UP AND COMPARISON WITH OTHER IMPLANTATION METHODS
    BUFFLE, PJ
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1976, 72 (02): : 226 - 231
  • [22] COMPARISON OF THRESHOLD BEHAVIOR ON LONG-TERM IMPLANTATION OF STIMULATING ELECTRODES IN LONGITUDINAL AND TRANSVERSE DIRECTION TO THE SKELETAL-MUSCLE
    DAVID, E
    KADUK, B
    MUND, K
    RAO, JR
    RICHTER, G
    WEIDLICH, E
    [J]. BIOMEDIZINISCHE TECHNIK, 1987, 32 (10): : 236 - 240
  • [23] Growth mechanisms of Co-Mo/TiO2 nano-composite coatings for long-term electrodeposition on disk electrodes
    Krawiec, H.
    Vignal, V.
    Krystianiak, A.
    Heintz, O.
    Latkiewicz, M.
    [J]. SURFACE & COATINGS TECHNOLOGY, 2019, 363 : 128 - 134
  • [24] Prospective Evaluation of the Quality and Long-Term Stability of Atrial Signals in Non-thoracotomy Defibrillation Electrodes: Comparison of Four Different Endocardial Electrograms
    Christian Wolpert
    Werner Jung
    Susanne Spehl
    Burghard Schumacher
    Heyder Omran
    Bahman Esmailzadeh
    Berndt Lüderitz
    [J]. Journal of Interventional Cardiac Electrophysiology, 1998, 2 : 351 - 355
  • [25] Prospective evaluation of the quality and long-term stability of atrial signals in non-thoracotomy defibrillation electrodes:: Comparison of four different endocardial electrograms
    Wolpert, C
    Jung, W
    Spehl, S
    Schumacher, B
    Omran, H
    Esmailzadeh, B
    Lüderitz, B
    [J]. JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 1998, 2 (04) : 351 - 355
  • [26] MOVEMENT-RELATED BETA AND GAMMA SYNCHRONIZATION OF THE SUPPLEMENTARY AND PRIMARY MOTOR CORTEX MEASURED IN EPILEPSY PATIENTS DURING LONG-TERM VIDEO EEG MONITORING WITH SUBDURAL ELECTRODES
    Tamas, G.
    Muthuraman, M.
    Fabo, D.
    Entz, L.
    Raethjen, J.
    Radics, P.
    Rasonyi, G.
    Halasz, P.
    Eross, L.
    [J]. EUROPEAN JOURNAL OF NEUROLOGY, 2011, 18 : 496 - 496
  • [27] Comparison between La0.6Sr0.4CoO3-d and LaNi0.6Co0.4O3-d infiltrated oxygen electrodes for long-term durable solid oxide fuel cells
    Ovtar, Simona
    Hauch, Anne
    Veltze, Sune
    Chen, Ming
    [J]. ELECTROCHIMICA ACTA, 2018, 266 : 293 - 304