Is normal or less than normal overall loudness preferred by first-time hearing aid users?

被引:29
|
作者
Smeds, K [1 ]
机构
[1] KTH S3, Signals Sensors & Syst, SE-10044 Stockholm, Sweden
来源
EAR AND HEARING | 2004年 / 25卷 / 02期
关键词
D O I
10.1097/01.AUD.0000120364.13671.E2
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Objective: Most prescriptive methods for nonlinear, wide dynamic range compression (WDRC) hearing aids are based on the assumption that a hearing-impaired listener should perceive amplified sounds at the same overall loudness as would a normal-hearing listener without amplification. However, some previous research on linear amplification has indicated that subjects prefer less overall gain than prescribed by the most commonly used prescriptive method for linear hearing aids, NAIL-R, a method that gives close to normal overall loudness for a mid-level input. The current study aims at comparing two prescriptive methods for WDRC hearing aids. The methods differ in the overall loudness they aim to give the hearing aid user. One method, called NormLoudn, is based on a generic method that prescribes gain.so that the overall loudness is restored to normal. Another method, called LessLoudn, is based on a hearing aid specific prescription, and gives the hearing aid user less than normal overall loudness. Do first-time hearing aid users prefer the method that restores overall loudness to normal or the method that gives less than normal overall loudness? Design: Twenty-one first-time hearing aid users with typical hearing losses for this group of clients participated in a crossover blinded field study where the two fitting methods were compared using a multi-programmable hearing aid, Danalogic 163D. Preference in the field was evaluated using interview, questionnaire, and diary. The field test was accompanied by laboratory tests, which included paired comparison judgments of preference and loudness and a speech recognition test. Loudness calculations were also used when interpreting the results, and a theoretical comparison with other prescriptive methods for WDRC hearing aids was made. Results: After necessary adjustments, the measured gain for the two methods was similar in gain-frequency shape, but NormLoudn gave more overall gain than LessLoudn. Generally, NormLoudn fittings led to calculated overall loudness that was close to normal, whereas LessLoudn fittings, in median, led to 3-7 phon less than normal calculated overall loudness according to the loudness model used. During the interview performed after the field test, 19 out of the 21 subjects stated that they preferred LessLoudn. Also the questionnaire and the diary showed a clear preference for LessLoudn in all types of listening situations. Paired comparisons of preference in the laboratory supported the findings in the field. LessLoudn was preferred to NormLoudn in all tested situations, except for soft speech in very soft noise where there was no significant preference for either method. Speech recognition scores were similar for the two fittings. The difference in calculated loudness was clearly distinguishable to the subjects and seemed to govern their preferences. Conclusions: LessLoudn, which gave less than normal overall loudness according to the loudness model used, was preferred both in the field and in the laboratory tests. Speech recognition scores were similar for both methods. A comparison between the measured gain for NormLoudn and the gain prescribed by CAMEQ, NAL-NL1, and DSL[i/o], suggests that all three prescriptive procedures (DSL[i/o] in particular) would probably overestimate the required gain for subjects without hearing aid experience and with mild to moderate hearing loss. When providing these clients with hearing aids, it seems important to include a careful adjustment of the overall gain to avoid overamplification if the prescription used aims at restoring overall loudness to normal according to the loudness model used here.
引用
收藏
页码:159 / 172
页数:16
相关论文
共 50 条
  • [21] Loudness Context Effects in Normal-Hearing Listeners and Cochlear-Implant Users
    Wang, Ningyuan
    Kreft, Heather A.
    Oxenham, Andrew J.
    JARO-JOURNAL OF THE ASSOCIATION FOR RESEARCH IN OTOLARYNGOLOGY, 2015, 16 (04): : 535 - 545
  • [22] Clinical study of Wider Sense on first-time hearing aid users (vol 28, pg 117, 1999)
    Berninger, E
    Karlsson, KK
    SCANDINAVIAN AUDIOLOGY, 2000, 29 (01): : 60 - 60
  • [23] Postural stability: assessment of auditory input in normal hearing individuals and hearing aid users
    Ibrahim, Iman
    da Silva, Sabrina Daniela
    Segal, Bernard
    Zeitouni, Anthony
    HEARING BALANCE AND COMMUNICATION, 2019, 17 (04) : 280 - 287
  • [24] A Quasi-Randomized Controlled Trial of the I-PLAN Intervention to Promote Hearing Aid Use Among First-Time Adult Hearing Aid Users
    Ismail, Afzarini H.
    Munro, Kevin J.
    Armitage, Christopher J.
    Marsden, Antonia
    Dawes, Piers D.
    TRENDS IN HEARING, 2021, 25
  • [25] Auditory, Visual, and Cognitive Abilities in Normal-Hearing Adults, Hearing Aid Users, and Cochlear Implant Users
    Ceuleers, Dorien
    Keppler, Hannah
    Degeest, Sofie
    Baudonck, Nele
    Swinnen, Freya
    Kestens, Katrien
    Dhooge, Ingeborg
    EAR AND HEARING, 2024, 45 (03): : 679 - 694
  • [26] Improving self-efficacy for hearing aid self-management: the early delivery of a multimedia-based education programme in first-time hearing aid users
    Gomez, Rachel
    Ferguson, Melanie
    INTERNATIONAL JOURNAL OF AUDIOLOGY, 2020, 59 (04) : 272 - 281
  • [27] Changing characteristics of first-time hearing aid applicants in The Netherlands in the past decade
    Brunenberg, DEM
    Chenault, MN
    Anteunis, LJC
    INTERNATIONAL JOURNAL OF AUDIOLOGY, 2004, 43 (04) : 211 - 217
  • [28] Evaluating a Theoretically Informed and Cocreated Mobile Health Educational Intervention for First-Time Hearing Aid Users: Qualitative Interview Study
    Maidment, David W.
    Heyes, Rachel
    Gomez, Rachel
    Coulson, Neil S.
    Wharrad, Heather
    Ferguson, Melanie A.
    JMIR MHEALTH AND UHEALTH, 2020, 8 (08):
  • [29] Hearing aid delay in open-fit devices: Preferred sound quality in listeners with normal and impaired hearing
    Lelic, Dina
    Stiefenhofer, Georg
    Lundorff, Ellen
    Neher, Tobias
    JASA EXPRESS LETTERS, 2022, 2 (10):
  • [30] Factors influencing degree of hearing loss at presentation, hearing aid choice, and usage in first time hearing aid users in Singapore
    Ho, Eu Chin
    Ong, Warren Ming Wu
    Li, KeXin
    Zhang, HanYu
    Bei, Yen Tze Eileen
    Medapati, Satya Vijay Reddy
    Seneviratna, Aruni
    INTERNATIONAL JOURNAL OF AUDIOLOGY, 2018, 57 (10) : 776 - 783