Urease-based biosensor for mercuric ions determination

被引:47
|
作者
Volotovsky, V
Nam, YJ
Kim, N
机构
[1] KOREA FOOD RES INST,KYONGGI DO 463420,SOUTH KOREA
[2] NATL ACAD SCI UKRAINE,INST MOL BIOL & GENET,UA-252143 KIEV,UKRAINE
关键词
biosensor; urease inhibition; heavy metal ions; charged polymer;
D O I
10.1016/S0925-4005(97)80340-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Urease immobilized into Nafion film on the surface of an ion sensitive field effect transistor (ISFET) has been used for heavy metal salt measurement. Enzyme immobilization into a negatively charged polymer seems to cause an increase in the effect of heavy metal inhibition due to cation accumulation in the polymeric matrix. Fifty percent urease inactivation was observed with 0.2 mu M Ag (I), 1.5 mu M Hg (II) or 5 mu M Cu (II). To make the urease-based biosensor sensitive only to mercuric ions, it is proposed to add small amounts (up to 100 mu M) of NaI into the sample (to suppress sensitivity to Ag ions) and to rewash the sensor in 100 mM solution of EDTA for 5 min to remove Cu ions. Restoration of enzyme activity after Hg (II) inhibition can be obtained by sensor rewashing in a 300 mM solution of NaI for-5 min. (C) 1997 Elsevier Science S.A.
引用
收藏
页码:233 / 237
页数:5
相关论文
共 50 条
  • [21] Application of potentiometric biosensor based on recombinant urease for urea determination in blood serum and hemodialyzate
    Marchenko, S. V.
    Kucherenko, I. S.
    Hereshko, A. N.
    Panasiuk, I. V.
    Soldatkin, O. O.
    El'skaya, A. V.
    Soldatkin, A. P.
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2015, 207 : 981 - 986
  • [22] Electrochemical Amyloid-Based Biosensor for the Determination of Metal Ions
    Park, Joohyung
    Lee, Wonseok
    Lee, Gyudo
    Choi, Hyunsung
    Kim, Minwoo
    Kim, Woong
    Na, Sungsoo
    Park, Jinsung
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2019, 166 (15) : B1497 - B1505
  • [23] Preparation and characterization of biosensor based on imprinted urease
    Teke, M.
    Sezginturk, M. K.
    Dinckaya, E.
    Telefoncu, A.
    [J]. FEBS JOURNAL, 2006, 273 : 344 - 344
  • [24] Evaluation of dust fixation effect of urease-based biological dust suppressant and its field application
    Li, Suning
    Hu, Xiangming
    Zhao, Yanyun
    Wu, Mingyue
    Feng, Yue
    Li, Xiao
    Guo, Yongxiang
    [J]. Journal of Environmental Management, 2024, 371
  • [25] Urease-based mucosal immunization against Helicobacter heilmannii infection induces corpus atrophy in mice
    Dieterich, C
    Bouzourène, H
    Blum, AL
    Corthésy-Theulaz, IE
    [J]. INFECTION AND IMMUNITY, 1999, 67 (11) : 6206 - 6209
  • [26] AMPEROMETRIC DETERMINATION OF PHOSPHATE IONS BY BIOSENSOR
    KULYS, J
    HIGGINS, IJ
    BANNISTER, JV
    [J]. BIOSENSORS & BIOELECTRONICS, 1992, 7 (03): : 187 - 191
  • [27] THE DETERMINATION OF SMALL AMOUNTS OF BROMIDE IN PRESENCE OF MERCURIC IONS
    TYRRELL, HJV
    DOWSON, BA
    [J]. ANALYST, 1960, 85 (1012) : 528 - 529
  • [28] Urease-based tests for Helicobacter pylori gastritis - Accurate for diagnosis but poor correlation with disease severity
    Lewis, JD
    Kroser, J
    Bevan, J
    Furth, EE
    Metz, DC
    [J]. JOURNAL OF CLINICAL GASTROENTEROLOGY, 1997, 25 (02) : 415 - 420
  • [29] REVERSIBILITY OF MERCURIC CHLORIDE INHIBITION OF UREASE
    EVERT, HE
    [J]. FEDERATION PROCEEDINGS, 1952, 11 (01) : 209 - 209
  • [30] Urea Biosensor Based on Immobilization of Urease on ZnO Nanoparticles
    Eghbali, Mostapha
    Farahbakhsh, Afshin
    Rohani, Aliasghar
    Pour, Ali Nakhaei
    [J]. ORIENTAL JOURNAL OF CHEMISTRY, 2015, 31 (02) : 1237 - 1242