Imprinted Zeolite Modified Carbon Paste Electrode as a Selective Sensor for Blood Glucose Analysis by Potentiometry

被引:4
|
作者
Khasanah, Miratul [1 ]
Widati, Alfa Akustia [1 ]
Handajani, Usreg Sri [1 ]
Harsini, Muji [1 ]
Ilmiah, Bahrotul [1 ]
Oktavia, Irene Dinda [1 ]
机构
[1] Univ Airlangga, Fac Sci & Technol, Dept Chem, Campus C,Jl Dr Ir H Soekarno MERR, Surabaya 60115, Indonesia
关键词
blood glucose; carbon paste electrode; imprinted zeolite; potentiometric sensor; HYDROTHERMAL SYNTHESIS; PERFORMANCE; MEMBRANES; NAA;
D O I
10.22146/ijc.49820
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Imprinted zeolite modified carbon paste (carbon paste-IZ) electrode had been developed as a sensor to analyze blood glucose content by potentiometry. The used zeolite was Lynde Type A (LTA) that synthesized with a mole ratio of Na2O, Al2O3, SiO2 and H2O of 4:1:1.8:270, respectively while non-imprinted zeolite was prepared with a mole ratio of glucose/Si of 0.0306. Glucose was then extracted from the zeolite framework using hot water (80 degrees C) to produce imprinted zeolite (IZ). The carbon paste-IZ electrode prepared from activated carbon, paraffin pastilles, and IZ with a mass ratio of 5:4:1 showed the best performance. The modified electrode demonstrated the measurement range of 10(-4)-10(-2) M, the Nernst factor of 29.55 mV/decade, the response time less than 120 s, and the detection limit of 5.62 x 10(-5) M. Ascorbic acid, uric acid, urea and creatinine did not interfere on the glucose analysis by potentiometry. Comparison test with spectrophotometry showed an accuracy of (90.7 +/- 1.4)% (n = 5), while the application of the electrode to analyze five spiked serum samples showed recovery of (92.2 +/- 1.3)% (n = 5). The electrode was stable for up to 9 weeks (168 times usage). Based on its performance, the developed electrode can be applied to analyze glucose in human serum sample and recommended for used in the medical field.
引用
收藏
页码:1301 / 1310
页数:10
相关论文
共 50 条
  • [31] Voltammetric Analysis of Oxymetazoline Hydrochloride at Zeolite - Modified Carbon Paste Electrode in Micellar Medium
    Hussien, Emad M.
    Rizk, Mohamed
    Daoud, Amira M.
    El-Eryan, Rasha Th
    [J]. ELECTROANALYSIS, 2021, 33 (07) : 1771 - 1777
  • [32] An Efficient Amperometric Sensor for Hydrogen Peroxide by Using a Carbon Paste Electrode Modified with Cobalt Impregnated Zeolite
    Norouzi, Banafsheh
    Moradian, Majid
    Malekan, Ali
    [J]. PORTUGALIAE ELECTROCHIMICA ACTA, 2015, 33 (02) : 111 - 124
  • [33] Studies on zeolite modified electrode .1. Ascorbic acid sensor based on carbon paste electrode containing Fe(III)Y zeolite
    Zou, MZ
    Xu, HD
    Lu, J
    Ru, QH
    [J]. CHINESE CHEMICAL LETTERS, 1997, 8 (03) : 247 - 250
  • [34] Selective voltammetric sensor for nanomolar detection of silver ions using carbon paste electrode modified with novel nanosized Ag(I)-imprinted polymer
    Zhiani, Rahele
    Ghanei-Motlag, Masoud
    Razavipanah, Iman
    [J]. JOURNAL OF MOLECULAR LIQUIDS, 2016, 219 : 554 - 560
  • [35] Application of Carbon Paste Electrodes Modified with Imprinted Zeolite X as Potentiometric Sensors for Amitriptyline Analysis in Pharmaceuticals
    Khasanah, Miratul
    Widati, Alfa Akustia
    Wahyuni, Ade Sukma
    Bureni, Dedy Samuel
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY RESEARCH, 2023, 10 (03): : 339 - 352
  • [36] An Electrochemical Sensor for Trimethoprim Based on a Magnetic Molecularly Imprinted Carbon Paste Electrode
    Liu, Peng
    Zhang, Ruiying
    Zheng, Liyan
    Cao, Qiue
    [J]. CHEMOSENSORS, 2023, 11 (06)
  • [37] Mycophenolate mofetil sensor based on molecularly imprinted polymer/multi-walled carbon nanotubes modified carbon paste electrode
    Momeneh, Hossein
    Gholivand, Mohammad Bagher
    [J]. ANALYTICAL BIOCHEMISTRY, 2018, 557 : 97 - 103
  • [38] GLUCOSE-OXIDASE IMMOBILIZED BENZOQUINONE CARBON PASTE ELECTRODE AS A GLUCOSE SENSOR
    IKEDA, T
    HAMADA, H
    MIKI, K
    SENDA, M
    [J]. AGRICULTURAL AND BIOLOGICAL CHEMISTRY, 1985, 49 (02): : 541 - 543
  • [39] A Sensitive Electrochemical Sensor for Moxifloxacin Hydrochloride Based on Nafion/Graphene Oxide/Zeolite Modified Carbon Paste Electrode
    Fekrya, Amany M.
    Abdel-Gawad, Soha A.
    Azab, Shereen M.
    Walcarius, Alain
    [J]. ELECTROANALYSIS, 2021, 33 (04) : 964 - 974
  • [40] A highly sensitive and selective sensor for trace uranyl (VI) ion based on a graphene-coated carbon paste electrode modified with ion imprinted polymer
    Wang, Zhimei
    Zhang, Di
    Xiao, Xilin
    Su, Changlin
    Li, Zhiyang
    Xue, Jinhua
    Hu, Nan
    Peng, Pengcheng
    Liao, Lifu
    Wang, Hongqing
    [J]. MICROCHEMICAL JOURNAL, 2020, 155