Electronics development for the ATLAS liquid argon calorimeter trigger and readout for future LHC running

被引:1
|
作者
Hopkins, Walter [1 ]
机构
[1] Univ Oregon, Eugene, OR 97403 USA
关键词
Liquid argon calorimeter; Electronics; HL-LHC upgrade;
D O I
10.1016/j.nima.2016.04.037
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The upgrade of the LHC will provide 7 times greater instantaneous and 10 times greater total luminosities than assumed in the original design of the ATLAS Liquid Argon (LAr) Calorimeters. Radiation tolerance criteria and an improved trigger system With higher acceptance rate and longer latency require an upgrade of the LAr readout electronics. In the first upgrade phase in 2019-2020, a trigger readout with up to 10 times higher granularity will be implemented. This allows an improved reconstruction of electromagnetic and hadronic showers and will reduce the background for electron, photon and energy flow signals at the first trigger level. The analog and digital signal processing components are currently in their final design stages and a fully functional demonstrator system is operated and tested on the LAr Calorimeters. In a second upgrade stage in 2024-2026, the readout of all 183,000 LAr Calorimeter cells will be performed without trigger selection at 40 MHz sampling rate and 16 bit dynamic range. Calibrated energies of all cells will be available at the second trigger level operating at 1 MHz, in order to allow further mitigation of pile-up effects in energy reconstruction. Radiation tolerant, low-power front-end electronics optimized for high pile-up conditions are currently being developed, including pre-amplifier, ADC and serializer components in 65-180 nm technology. This contribution will give an overview of the future LAr readout electronics and present research results from the two upgrade programs. (C) 2016 Published by Elsevier B.V.
引用
收藏
页码:599 / 602
页数:4
相关论文
共 50 条
  • [31] ATLAS liquid argon calorimeter front end electronics
    Buchanan, N. J.
    Chen, L.
    Gingrich, D. M.
    Liu, S.
    Chen, H.
    Damazio, D.
    Densing, F.
    Duffin, S.
    Farrell, J.
    Kandasamy, S.
    Kierstead, J.
    Lanni, F.
    Lissauer, D.
    Ma, H.
    Makowiecki, D.
    Muller, T.
    Radeka, V.
    Rescia, S.
    Ruggiero, R.
    Takai, H.
    Wolniewicz, K.
    Ghazlane, H.
    Hoummada, A.
    Hervas, L.
    Hott, T.
    Wilkens, H. G.
    Ban, J.
    Boettcher, S.
    Brooijmans, G.
    Chi, C. -Y.
    Caughron, S.
    Cooke, M.
    Copic, K.
    Dannheim, D.
    Gara, A.
    Haas, A.
    Katsanos, I.
    Parsons, J. A.
    Simion, S.
    Sippach, W.
    Zhang, L.
    Zhou, N.
    Eckstein, P.
    Kobel, M.
    Ladygin, E.
    Auge, E.
    Bernier, R.
    Bouchel, M.
    Bozzone, A.
    Breton, D.
    JOURNAL OF INSTRUMENTATION, 2008, 3
  • [32] Phase-I Trigger Readout Electronics Upgrade of the ATLAS Liquid-Argon Calorimeters
    Mori, Tatsuya
    PHYSICS OF PARTICLES AND NUCLEI LETTERS, 2016, 13 (05) : 541 - 546
  • [33] NEW READOUT ELECTRONICS FOR THE VENUS LIQUID ARGON CALORIMETER AT TRISTAN
    FUKUSHIMA, Y
    SHIRAI, J
    UNNO, Y
    TANAKA, R
    MURAKAMI, H
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1989, 36 (01) : 670 - 674
  • [34] ATLAS Liquid Argon Calorimeter Commissioning for LHC Run 3
    Haghighat, Sana Ketabchi
    EIGHTH ANNUAL CONFERENCE ON LARGE HADRON COLLIDER PHYSICS, LHCP2020, 2021,
  • [35] Electronics of the Atlas Liquid Argon Calorimeter and its Precision Calibration
    Ye, Jingbo
    2009 16TH IEEE-NPSS REAL TIME CONFERENCE, 2009, : 255 - 258
  • [36] Performance and quality control of a radiation-hard 12-bit 40 MSPS ADC for the ATLAS Liquid Argon calorimeter trigger readout electronics Phase-I upgrade at the LHC
    Andeen, T.
    Ban, J.
    Brooijmans, G.
    Emerman, A.
    Kinget, P.
    Kuppambatti, J.
    Mahon, D.
    Ochoa, I.
    Sippach, W.
    Wang, Q.
    JOURNAL OF INSTRUMENTATION, 2020, 15 (04):
  • [37] Cold electronics for the liquid Argon hadronic endcap calorimeter of ATLAS
    Ban, J
    Brettel, H
    Cwienk, WD
    Fent, J
    Kurchaninov, L
    Oberlack, H
    Schacht, P
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 1687 - 1691
  • [38] Demonstrator System for the Phase-I Upgrade of the Trigger Readout Electronics of the ATLAS Liquid Argon Calorimeters
    Chen, Kai
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [39] A LIQUID ARGON CALORIMETER FOR LHC
    PETROFF, P
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 316 (01): : 19 - 28
  • [40] FATALIC: A fully integrated electronics readout for the ATLAS tile calorimeter at the HL-LHC
    Angelidakis, S.
    Barbe, W.
    Bonnefoy, R.
    Fayard, C.
    Madar, R.
    Manen, S.
    Mercier, M-L
    Nibigira, E.
    Royer, L.
    Soulier, A.
    Pallin, D.
    Vazeille, F.
    Vandaele, R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 936 : 316 - 318