Simulation, design, and test of an elliptical surface coil for magnetic resonance imaging and spectroscopy

被引:7
|
作者
Giovannetti, Giulio [1 ,2 ]
Flori, Alessandra [2 ]
De Marchi, Daniele [2 ,3 ]
Matarazzo, Giuseppe
Frijia, Francesca [2 ]
Burchielli, Silvia [2 ]
Montanaro, Domenico [2 ]
Aquaro, Giovanni Donato [2 ]
Menichetti, Luca [1 ,2 ]
机构
[1] CNR, Natl Res Council, Inst Clin Physiol, Pisa, Italy
[2] Fdn CNR Reg Toscana G Monasterio, Pisa, Italy
[3] AITIRM, Florence, Italy
关键词
coil simulation; inductance; magnetic field; resistance; signal-to-noise ratio; TO-NOISE RATIO; RADIOFREQUENCY COIL;
D O I
10.1002/cmr.b.21361
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The simplest design of surface coils for magnetic resonance imaging (MRI) applications is circular and square loops, both producing a magnetic field perpendicular to the coil plane in the central region-of-interest (ROI), with an amplitude that decreases along the coil axis. However, a surface coil constituted by a loop with different geometry could be necessary when particular field-of-views (FOVs) are desired, especially for performing imaging in an elongated region. This can be achieved by using an elliptical loop, which can guarantee a wide longitudinal FOV and a good penetration in deep sample regions. This work proposes the application of a method for elliptical coil Signal-to-Noise Ratio (SNR) estimation previously developed for circular and square loop design, in which coil inductance and resistance are analytically calculated and the magnetic field pattern is estimated using the magnetostatic approach, while the sample-induced resistance is calculated with the vector potential calculation method. In the second part of the paper, we propose the simulation and the design of a transmit/receive elliptical coil for MRI in mice with a 3T clinical scanner. We also evaluated the coil performance in a preliminary magnetic resonance spectroscopy (MRS) study in phantom.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] MAGNETIC-RESONANCE IMAGING OF THE TEMPORAL BONES - COMPARISON OF BILATERAL SURFACE COIL AND HEAD COIL TECHNIQUES
    MANZIONE, JV
    PLEWES, DB
    KIDO, DK
    TOTTERMAN, S
    EKHOLM, SE
    SIMON, JH
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1988, 9 (05) : 1023 - 1023
  • [42] The design of spin probes for electron magnetic resonance spectroscopy and imaging
    Sutcliffe, LH
    PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (07): : 1987 - 1993
  • [43] An open transverse z-gradient coil design for magnetic resonance imaging
    Dodd, SJ
    Williams, DS
    Olson, C
    Silva, AC
    Koretsky, AP
    Ho, C
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2002, 73 (05): : 2208 - 2210
  • [44] Inductively-overcoupled coil design for high resolution magnetic resonance imaging
    Bilgen, Mehmet
    BIOMEDICAL ENGINEERING ONLINE, 2006, 5 (1)
  • [45] Inductively-overcoupled coil design for high resolution magnetic resonance imaging
    Mehmet Bilgen
    BioMedical Engineering OnLine, 5
  • [46] Inverse Design of a Phased-Array Coil for Breast Magnetic Resonance Imaging
    Li, Yu
    Liu, Feng
    Weber, Ewald
    Li, Bing
    Crozier, Stuart
    CONCEPTS IN MAGNETIC RESONANCE PART B-MAGNETIC RESONANCE ENGINEERING, 2009, 35B (04) : 221 - 231
  • [47] Equivalent magnetic dipole method used to design gradient coil for unilateral magnetic resonance imaging
    徐征
    李想
    郭盼
    吴嘉敏
    Chinese Physics B, 2018, 27 (05) : 549 - 554
  • [48] Equivalent magnetic dipole method used to design gradient coil for unilateral magnetic resonance imaging
    Xu, Zheng
    Li, Xiang
    Guo, Pan
    Wu, Jia-Min
    CHINESE PHYSICS B, 2018, 27 (05)
  • [49] Helmholtz Coil for Magnetic Resonance Prostate Imaging
    Climer, Nathan
    Holmes, Ben
    Krishnaswamy, Deepa
    2010 IEEE 36TH ANNUAL NORTHEAST BIOENGINEERING CONFERENCE, 2010,
  • [50] Magnetic resonance imaging and spectroscopy
    Jackson, GD
    Connelly, A
    CURRENT OPINION IN NEUROLOGY, 1996, 9 (02) : 82 - 88