Detecting sleep outside the clinic using wearable heart rate devices

被引:17
|
作者
Perez-Pozuelo, Ignacio [1 ,2 ]
Posa, Marius [3 ]
Spathis, Dimitris [4 ]
Westgate, Kate [1 ]
Wareham, Nicholas [1 ]
Mascolo, Cecilia [4 ]
Brage, Soren [1 ]
Palotti, Joao [5 ]
机构
[1] Univ Cambridge, Sch Clin Med, MRC Epidemiol Unit, Cambridge, England
[2] Alan Turing Inst, London, England
[3] Univ Cambridge, Sch Clin Med, Cambridge, England
[4] Univ Cambridge, Dept Comp Sci & Technol, Cambridge, England
[5] Hamad Bin Khalifa Univ, Qatar Comp Res Inst, Doha, Qatar
基金
英国工程与自然科学研究理事会;
关键词
WAKE IDENTIFICATION; WRIST ACTIGRAPHY; MEDICINE; DURATION; ALCOHOL;
D O I
10.1038/s41598-022-11792-7
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The adoption of multisensor wearables presents the opportunity of longitudinal monitoring of sleep in large populations. Personalized yet device-agnostic algorithms can sidestep laborious human annotations and objectify cross-cohort comparisons. We developed and tested a heart rate-based algorithm that captures inter- and intra-individual sleep differences in free-living conditions and does not require human input. We evaluated it on four study cohorts using different research-and consumer-grade devices for over 2000 nights. Recording periods included both 24 h free-living and conventional lab-based night-only data. We compared our optimized method against polysomnography, sleep diaries and sleep periods produced through a state-of-the-art acceleration based method. Against sleep diaries, the algorithm yielded a mean squared error of 0.04-0.06 and a total sleep time (TST) deviation of -2.70 (+/- 5.74) and 12.80 (+/- 3.89) minutes, respectively. When evaluated with PSG lab studies, the MSE ranged between 0.06 and 0.11 yielding a time deviation between -29.07 and -55.04 minutes. These results showcase the value of this open-source, device-agnostic algorithm for the reliable inference of sleep in free-living conditions and in the absence of annotations.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Heart Rate Variability Control Using a Biofeedback and Wearable System
    Viera, Eduardo
    Kaschel, Hector
    Valencia, Claudio
    SENSORS, 2022, 22 (19)
  • [32] Evaluating reliability in wearable devices for sleep staging
    Birrer, Vera
    Elgendi, Mohamed
    Lambercy, Olivier
    Menon, Carlo
    NPJ DIGITAL MEDICINE, 2024, 7 (01)
  • [33] Evaluating reliability in wearable devices for sleep staging
    Vera Birrer
    Mohamed Elgendi
    Olivier Lambercy
    Carlo Menon
    npj Digital Medicine, 7
  • [34] Measurement latency significantly contributes to reduced heart rate measurement accuracy in wearable devices
    Støve M.P.
    Holm R.S.
    Kjaersgaard A.S.
    Duncker K.
    Jensen M.R.
    Larsen B.T.
    Journal of Medical Engineering and Technology, 2020, 44 (03): : 125 - 132
  • [35] Heart Rate Variability Measured from Wearable Devices as a Marker of Disease Severity in Tetanus
    Hai, Ho Bich
    Cattrall, Jonathan W. S.
    Hao, Nguyen Van
    Van, Hoang Minh Tu
    Thuy, Duong Bich
    Nhat, Phung Tran Huy
    Khanh, Phan Nguyen Quoc
    Duong, Ha Thi Hai
    Duong, Tran Duc
    Lu, Ping
    Phuong, Le Thanh
    Greeff, Heloise
    Zhu, Tingting
    Yen, Lam Minh
    Clifton, David
    Thwaites, C. Louise
    AMERICAN JOURNAL OF TROPICAL MEDICINE AND HYGIENE, 2024, 110 (01): : 165 - 169
  • [36] THE EFFECT OF SKIN TONE ON ACCURACY OF HEART RATE MEASUREMENT IN WEARABLE DEVICES: A SYSTEMATIC REVIEW
    Koerber, Daniel
    Khan, Shawn
    Shamsheri, Tahmina
    Kirubarajan, Abirami
    Mehta, Sangeeta
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2022, 79 (09) : 1990 - 1990
  • [37] The Analysis of Sleep Stages with Motion and Heart Rate Signals from a Handheld Wearable Device
    Lee, Seungmin
    Nam, Seungyoon
    Shin, Hyunsoon
    2016 INTERNATIONAL CONFERENCE ON INFORMATION AND COMMUNICATION TECHNOLOGY CONVERGENCE (ICTC 2016): TOWARDS SMARTER HYPER-CONNECTED WORLD, 2016, : 1135 - 1137
  • [38] Portable recording for detecting sleep disorder breathing in patients under the care of a heart failure clinic
    Peter Dolliner
    Lindsay Brammen
    Senta Graf
    Martin Huelsmann
    Leopold Stiebellehner
    Andreas Gleiss
    Philipp Ubl
    Guenter Steurer
    Clinical Research in Cardiology, 2013, 102 : 535 - 542
  • [39] Self-monitoring - usability evaluation of heart rate monitoring using wearable devices in patients with acquired brain injury
    Stove, Morten P.
    Larsen, Birgit T.
    EUROPEAN JOURNAL OF PHYSIOTHERAPY, 2020, 22 (06) : 364 - 372
  • [40] Detecting Self-harming Activities with Wearable Devices
    Malott, Levi
    Bharti, Pratool
    Hilbert, Nicholas
    Gopalakrishna, Ganesh
    Chellappan, Sriram
    2015 IEEE INTERNATIONAL CONFERENCE ON PERVASIVE COMPUTING AND COMMUNICATION WORKSHOPS (PERCOM WORKSHOPS), 2015, : 597 - 602