Continuous central venous and pulmonary artery oxygen saturation monitoring in the critically ill

被引:290
|
作者
Reinhart, K
Kuhn, HJ
Hartog, C
Bredle, DL
机构
[1] Univ Jena, Dept Anesthesia & Intens Care Med, D-07747 Jena, Germany
[2] Univ Wisconsin, Dept Kinesiol, Eau Claire, WI 54701 USA
关键词
central venous oxygen saturation; mixed venous oxygen saturation; fiberoptic; oximetry;
D O I
10.1007/s00134-004-2337-y
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective. To compare the course of continuously measured mixed and central venous O-2 saturations in high-risk patients and to evaluate the impact of various factors that might interfere with reflection spectrophotometry. Design and setting. Prospective, descriptive study in the interdisciplinary ICU of a university hospital. Patients. 32 critically ill patients with triple-lumen central vein catheters, including 29 patients requiring pulmonary artery catheterization. Interventions. The accuracy of fiberoptic measurements was assessed by comparison to reference co-oximeter results at regular intervals. We examined the effect on measurement accuracy of physiological variables including hematocrit, hemoglobin, pH, temperature, and the administration of various solutions via central venous catheter. Continuous parallel measurements of SvO(2) and ScvO(2) were performed in patients with each type of catheters over a total observation time of 1097 h. Results. ScvO(2) values were more accurate and stable than in vitro oximeter measurements (r=0.96 from 150 samples, mean difference 0.15%, average drift 0.10%/day) and was not significantly affected by synchronous infusion therapy or by changes in hematocrit, hemoglobin, pH, or temperature. ScvO(2) values closely paralleled SvO(2), whether measured in vitro (r=0.88 from 150 samples) or in vivo (r=0.81 from 395,128 samples) but averaged about 7+/-4 saturation percentage higher. ScvO(2) changed in parallel in 90% of the 1,498 instances in which SvO(2) changed more than 5% (over an average of 43 min). Conclusions. Continuous fiberoptic measurement of central vein O-2 saturation has potential to be a reliable and convenient tool which could rapidly warn of acute change in the oxygen supply/demand ratio of critically ill patients.
引用
收藏
页码:1572 / 1578
页数:7
相关论文
共 50 条
  • [41] EVALUATION OF A 7.5 FRENCH PULMONARY CATHETER FOR CONTINUOUS MONITORING OF CEREBRAL VENOUS OXYGEN-SATURATION
    OLSEN, KS
    MADSEN, PL
    BORME, T
    SCHMIDT, JF
    [J]. JOURNAL OF NEUROSURGICAL ANESTHESIOLOGY, 1994, 6 (04) : 233 - 238
  • [42] Continuous central venous oxygen saturation monitoring under varying physiological conditions in an animal model
    Kissoon, N.
    Spenceley, N.
    Krahn, G.
    Milner, R.
    [J]. ANAESTHESIA AND INTENSIVE CARE, 2010, 38 (05) : 883 - 889
  • [43] Pulmonary atresia with ventricular septal defect: A case for central venous pressure and oxygen saturation monitoring
    Weiss, BM
    Atanassoff, PG
    Jenni, R
    Walder, B
    Wight, E
    [J]. YALE JOURNAL OF BIOLOGY AND MEDICINE, 1998, 71 (01): : 15 - 21
  • [44] Continuous cardiac output and mixed venous oxygen saturation monitoring
    Cariou, A
    Monchi, M
    Dhainaut, JF
    [J]. JOURNAL OF CRITICAL CARE, 1998, 13 (04) : 198 - 213
  • [45] OPTIMIZING OXYGEN DELIVERY IN THE CRITICALLY ILL: THE UTILITY OF LACTATE AND CENTRAL VENOUS OXYGEN SATURATION (SCVO2) AS A ROADMAP OF RESUSCITATION IN SHOCK
    Joshi, Raj
    de Witt, Benjamin
    Mosier, Jarrod M.
    [J]. JOURNAL OF EMERGENCY MEDICINE, 2014, 47 (04): : 493 - 500
  • [46] Femoral venous oxygen saturation is no surrogate for central venous oxygen saturation
    van Beest, Paul A.
    van der Schors, Alice
    Liefers, Henriette
    Coenen, Ludo G. J.
    Braam, Richard L.
    Habib, Najib
    Braber, Annemarije
    Scheeren, Thomas W. L.
    Kuiper, Michael A.
    Spronk, Peter E.
    [J]. CRITICAL CARE MEDICINE, 2012, 40 (12) : 3196 - 3201
  • [47] Femoral venous oxygen saturation is no surrogate for central venous oxygen saturation
    A Van der Schors
    P Van Beest
    H Liefers
    L Coenen
    R Braam
    P Spronk
    [J]. Critical Care, 15 (Suppl 1):
  • [48] CENTRAL MIXED AND SPLANCHNIC VENOUS OXYGEN-SATURATION MONITORING
    DAHN, MS
    LANGE, MP
    JACOBS, LA
    [J]. INTENSIVE CARE MEDICINE, 1988, 14 (04) : 373 - 378
  • [49] MIXED VENOUS OXYGEN-SATURATION - ITS ROLE IN THE ASSESSMENT OF THE CRITICALLY ILL PATIENT
    KANDEL, G
    ABERMAN, A
    [J]. ARCHIVES OF INTERNAL MEDICINE, 1983, 143 (07) : 1400 - 1402
  • [50] Product evaluation of mixed venous oxygen saturation and continuous cardiac output measurements by pulmonary artery catheters
    Yu, MH
    Yang, S
    [J]. CRITICAL CARE MEDICINE, 1999, 27 (01) : A151 - A151