The Added Value of Double Dose Gadolinium Enhanced 3D T2 Fluid-Attenuated Inversion Recovery for Evaluating Small Brain Metastases

被引:16
|
作者
Ahn, Sung Jun [1 ]
Chung, Tae-Sub [1 ]
Chang, Jong-Hee [2 ]
Lee, Seung-Koo [1 ]
机构
[1] Yonsei Univ Coll Med, Dept Radiol, Seoul 120752, South Korea
[2] Yonsei Univ Coll Med, Dept Neurosurg, Seoul 120752, South Korea
关键词
CNS; MR-imaging; metastases; MR; MANAGEMENT; SINGLE; FLAIR; SIZE;
D O I
10.3349/ymj.2014.55.5.1231
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: Single dose gadolinium (Gd) enhanced fluid-attenuated inversion recovery (FLAIR) is helpful for visualizing superficial parenchymal metastases. However, the usefulness of FLAIR with a higher dose of Gd is uncertain. The aim of our study was two-folds: first, to prove that the signal to noise ratio (SNR) of small brain metastases is higher than large brain metastases on double-dose (DD) enhanced FLAIR and, second, to explore the added value of DD Gd enhanced FLAIR in relation to T1 GRE for evaluating small brain metastases. Materials and Methods: For the first purpose, 50 pairs of small (2 mm<diameter <= 5 mm) and large brain metastases (diameter >5 mm) were included. The difference in the SNR and contrast ratio (CR) between small and large metastases on DD Gd-enhanced 3D T2 FLAIR was compared by Wilcoxon signed-rank tests. For the second purpose, a total of 404 small metastases were included. The diagnostic sensitivities between 3D T1 gradient echo (GRE) alone and combined results of 3D Ti GRE and 3D T2 FLAIR were compared with McNemar test. Results: The SNR and CR of small brain metastases were significantly higher than those of large brain metastases (p<0.001). In qualitative analysis, the diagnostic sensitivities for small brain metastases were significantly higher for 3D Ti GRE plus 3D 12 FLAIR than 3D Ti GRE alone regardless of scan time (p<0.001). Conclusion: Small brain metastases showed higher signal intensity than large brain metastases on the DD Gd enhanced 3D 12 FLAIR images. DD Gd enhanced 3D T2 FLAIR imaging may have a complementary role to 3D Ti GRE for evaluating small brain Metastases.
引用
收藏
页码:1231 / 1237
页数:7
相关论文
共 50 条
  • [21] Optimal Detection of Subtle Gadolinium Leakage in CSF with Heavily T2-Weighted Fluid-Attenuated Inversion Recovery Imaging
    Freeze, W. M.
    ter Weele, D. N.
    Palm, W. M.
    van Hooren, R. W.
    Hoff, E., I
    Jansen, J. F. A.
    Jacobs, H. I. L.
    Verhey, F. R.
    Backes, W. H.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2019, 40 (09) : 1481 - 1483
  • [22] Diagnostic value of 3D fluid attenuated inversion recovery sequence in multiple sclerosis
    Gramsch, Carolin
    Nensa, Felix
    Kastrup, Oliver
    Maderwald, Stefan
    Deuschl, Cornelius
    Ringelstein, Adrian
    Schelhorn, Juliane
    Forsting, Michael
    Schlamann, Marc
    ACTA RADIOLOGICA, 2015, 56 (05) : 622 - 627
  • [23] Diagnostic value of contrast-enhanced fluid-attenuated inversion-recovery and delayed contrast-enhanced brain MRI in multiple sclerosis
    Bagheri, Mohammad Hadi
    Meshksar, Arash
    Nabavizadeh, Seyyed Ali
    Borhani-Haghighi, Afshin
    Ashjazadeh, Nahid
    Nikseresht, Alireza R.
    ACADEMIC RADIOLOGY, 2008, 15 (01) : 15 - 23
  • [24] 3D FLAIRED: 3D fluid attenuated inversion recovery for enhanced detection of lesions in multiple sclerosis
    Polak, Paul
    Magnano, Christopher
    Zivadinov, Robert
    Poloni, Guy
    MAGNETIC RESONANCE IN MEDICINE, 2012, 68 (03) : 874 - 881
  • [25] Brain White Matter Hyperintensity Lesion Characterization in T2 Fluid-Attenuated Inversion Recovery Magnetic Resonance Images: Shape, Texture, and Potential Growth
    Gwo, Chih-Ying
    Zhu, David C.
    Zhang, Rong
    FRONTIERS IN NEUROSCIENCE, 2019, 13
  • [26] A New Tumor Delineation Method for Brain Metastases Radiotherapy by jointly Referring to Contrast-Enhanced T1- Weighted and Fluid-Attenuated Inversion Recovery MRI
    Soyama, Maki
    Azumi, Rieko
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2020, 12 (07)
  • [27] Comparison of 3D Double Inversion Recovery (DIR) versus 3D Fluid Attenuated Inversion Recovery (FLAIR) in precise diagnosis of acute optic neuritis
    Murumkar, Vivek
    Baishya, Priyanka Priyadarshini
    Kulanthaivelu, Karthik
    Saini, Jitender
    Manjunath, Netravathi
    Gupta, Rakesh Kumar
    EUROPEAN JOURNAL OF RADIOLOGY, 2022, 155
  • [28] Comparison of the Added Value of Contrast-Enhanced 3D Fluid-Attenuated Inversion Recovery and Magnetization-Prepared Rapid Acquisition of Gradient Echo Sequences in Relation to Conventional Postcontrast T1-Weighted Images for the Evaluation of Leptomeningeal Diseases at 3T
    Fukuoka, H.
    Hirai, T.
    Okuda, T.
    Shigematsu, Y.
    Sasao, A.
    Kimura, E.
    Hirano, T.
    Yano, S.
    Murakami, R.
    Yamashita, Y.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2010, 31 (05) : 868 - 873
  • [29] Contrast-enhanced fluid-attenuated inversion recovery vs. contrast-enhanced spin echo T1-weighted brain imaging
    Falzone, Cristian
    Rossi, Federica
    Calistri, Maurizio
    Tranquillo, Massimo
    Baroni, Massimo
    VETERINARY RADIOLOGY & ULTRASOUND, 2008, 49 (04) : 333 - 338
  • [30] Determination of Efficiency of 3D Fluid-Attenuated Inversion Recovery (FLAIR) in the Imaging of Multiple Sclerosis in Comparison With 2D FLAIR at 3-Tesla MRI
    Kummari, Satyanarayana
    Burra, Kiran Goud
    Reddy, Vudem Ranjith Kumar
    Das, Saraswata
    Anilkumar, Challa
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (11)