Electrical resistance changes as an alternate method for monitoring the corrosion of steel in concrete and mortar

被引:20
|
作者
Cella, PA [1 ]
Taylor, SR
机构
[1] Univ Virginia, Ctr Electrochem Sci & Engn, Charlottesville, VA 22901 USA
[2] Univ Virginia, Dept Mat Sci & Engn, Charlottesville, VA 22901 USA
关键词
cementitious materials; electrochemical impedance spectroscopy; open-circuit potential; linear polarization; resistance change measurements; x-ray photoelectron spectroscopy;
D O I
10.5006/1.3280599
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A very sensitive, unambiguous, and simple procedure was introduced for the assessment of corrosion in concrete. This method consists of making resistance change measurements (RCM) on small diameter (228.6 mum) 1040 steel (UNS G10400) wires embedded in concrete (or mortar) prisms and correcting the measurements for temperature by use of a noncorroding control wire. Metal loss caused by corrosion lead to a loss in cross-sectional area and, hence, an increase in resistance. Through proper temperature correction, these methods lead to a sensitivity of 1 mum diameter loss. The wires were heat-treated at 536degreesC for 1 h to attain an oxide chemistry similar to bare rebar as determined by x-ray photoelectron spectroscopy. Although this method was designed for the evaluation of inhibitive admixtures, it was used in the present study to examine supplementary cementitious materials. The rate of steel corrosion in these was assessed by RCM using mortar prisms (25.4 cm by 5 cm by 5 cm) of the following composition: plain mortar, 50% stag, 25% fly ash, and 6% silica fume. These prisms were ponded with 0.6 M sodium chloride (NaCl)for 140 days and subsequently wet/dry cycled for art additional 140 clays. Wires in blocks containing slag, fly ash, and silica fume showed fewer instances of corrosion and lower average rates of corrosion than wires in plain mortar. Stag additions were shown to be more effective than fly ash additions at mitigating corrosion, while silica fume was effective only at deeper cover depths. The RCM method also was compared to electrochemical methods: open-circuit potential measurements, (half-cell potentials), linear polarization, and electrochemical impedance spectroscopy. In all cases, RCM was more sensitive and definitive on the steel corrosion rates within the mortar. The simplicity and low cost of this approach make it ideally suited as a standard method to assess corrosion prevention methods in concrete.
引用
收藏
页码:951 / 959
页数:9
相关论文
共 50 条
  • [41] Effect of Electrical Injection of Corrosion Inhibitor on the Corrosion of Steel Rebar in Chloride-Contaminated Repair Mortar
    The Huyen Nguyen
    Tuan Anh Nguyen
    Thien Vuong Nguyen
    Van Khu Le
    Thi Mai Thanh Dinh
    Hoang Thai
    Shi, Xianming
    INTERNATIONAL JOURNAL OF CORROSION, 2015, 2015
  • [42] Investigation of monitoring method for detecting the cracks due to steel corrosion in concrete using specific resistivity
    Nishida, T.
    Iwanami, M.
    Otsuki, N.
    Kawabata, Y.
    LIFE-CYCLE OF STRUCTURAL SYSTEMS: DESIGN, ASSESSMENT, MAINTENANCE AND MANAGEMENT, 2015, : 1532 - 1537
  • [43] Monitoring of rebar corrosion by means of the electrical resistance probes
    Wu, Xu
    Shi, Jianguang
    Lin, Changjian
    PROCEEDINGS OF INTERNATIONAL CONFERENCE ON HEALTH MONITORING OF STRUCTURE, MATERIALS AND ENVIRONMENT, VOLS 1 AND 2, 2007, : 1234 - +
  • [44] Overview on electrochemical parameters to assess the corrosion state of steel reinforcement in CAC mortar and concrete
    Sanjuán, MA
    JOURNAL OF MATERIALS SCIENCE, 2000, 35 (01) : 105 - 108
  • [45] Overview on electrochemical parameters to assess the corrosion state of steel reinforcement in CAC mortar and concrete
    M. A. Sanjuán
    Journal of Materials Science, 2000, 35 : 105 - 108
  • [46] THE INFLUENCE OF INTERNAL RELATIVE-HUMIDITY ON THE RATE OF CORROSION OF STEEL EMBEDDED IN CONCRETE AND MORTAR
    ENEVOLDSEN, JN
    HANSSON, CM
    HOPE, BB
    CEMENT AND CONCRETE RESEARCH, 1994, 24 (07) : 1373 - 1382
  • [47] ONLINE CORROSION MONITORING AND CATHODIC PROTECTION OF A STEEL STRUCTURE IN CONCRETE
    Brem, Martin
    Buechler, Markus
    Mailand, Irene
    RILEM WORKSHOP ON LONG-TERM PERFORMANCE OF CEMENTITIOUS BARRIERS AND REINFORCED CONCRETE IN NUCLEAR POWER PLANTS AND WASTE MANAGEMENT, 2009, 64 : 335 - +
  • [48] Simulation of wireless sensor for monitoring corrosion of reinforcement steel in concrete
    Xu, Gaowa
    Wu, Jin
    Wang, Zhe
    Wang, Zhong
    CIVIL ENGINEERING AND URBAN PLANNING III, 2014, : 365 - 369
  • [49] AN OPTICAL FIBER SENSOR FOR MONITORING STEEL CORROSION IN CONCRETE STRUCTURES
    Leung, Christopher K. Y.
    Wan, Kai Tai
    Chen, Liquan
    ADVANCES IN CONCRETE STRUCTURAL DURABILITY, PROCEEDINGS OF ICDCS2008, VOLS 1 AND 2, 2008, : 109 - 115
  • [50] A NEW PROBE FOR MONITORING STEEL CORROSION IN OFFSHORE CONCRETE PLATFORMS
    GJORV, OE
    VENNESLAND, O
    MATERIALS PERFORMANCE, 1982, 21 (01) : 33 - 35