High-performance liquid chromatographic separations of stereoisomers of chiral basic agrochemicals with polysaccharide-based chiral columns and polar organic mobile phases

被引:32
|
作者
Matarashvili, Iza [1 ]
Shvangiradze, Iamze [2 ]
Chankvetadze, Lali [1 ]
Sidamonidze, Shota [1 ,2 ]
Takaishvili, Nino [1 ]
Farkas, Tivadar [3 ]
Chankvetadze, Bezhan [1 ]
机构
[1] Tbilisi State Univ, Sch Exact & Nat Sci, Inst Phys & Analyt Chem, GE-0179 Tbilisi, Georgia
[2] Georgian Univ St Andrew Apostle, Fac Informat Math & Nat Sci, Dept Ecol & Environm Protect, GE-0179 Tbilisi, Georgia
[3] Phenomenex Inc, Torrance, CA USA
基金
美国国家科学基金会;
关键词
Chiral agrochemicals; Enantiomer elution order; High-performance liquid chromatography; Stereoisomer elution order; NITROGEN-HETEROCYCLIC PESTICIDES; STEREOSELECTIVE TRANSFORMATION; DIRECT ENANTIOSEPARATION; ENANTIOMERIC RESOLUTION; MASS-SPECTROMETRY; STATIONARY PHASES; FIELD CONDITIONS; ELUTION ORDER; TOXICITY; SOIL;
D O I
10.1002/jssc.201500919
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The separation of the stereoisomers of 23 chiral basic agrochemicals was studied on six different polysaccharide-based chiral columns in high-performance liquid chromatography with various polar organic mobile phases. Along with the successful separation of analyte stereoisomers, emphasis was placed on the effect of the chiral selector and mobile phase composition on the elution order of stereoisomers. The interesting phenomenon of reversal of enantiomer/stereoisomer elution order function of the polysaccharide backbone (cellulose or amylose), type of derivative (carbamate or benzoate), nature, and position of the substituent(s) in the phenylcarbamate moiety (methyl or chloro) and the nature of the mobile phase was observed. For several of the analytes containing two chiral centers all four stereoisomers were resolved with at least one chiral selector/mobile phase combination.
引用
收藏
页码:4173 / 4179
页数:7
相关论文
共 50 条
  • [41] Chiral separations in reversed-phase liquid chromatography: Evaluation of several polysaccharide-based chiral stationary phases for a separation strategy update
    Younes, Ahmed A.
    Mangelings, Debby
    Vander Heyden, Yvan
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1269 : 154 - 167
  • [42] Recent trends in preparation, investigation and application of polysaccharide-based chiral stationary phases for separation of enantiomers in high-performance liquid chromatography
    Chankvetadze, Bezhan
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2020, 122
  • [43] Liquid chromatographic separation of the enantiomers of phenylthiohydantoin α-amino acids derivatives on polysaccharide-based chiral stationary phases
    Lee, WJ
    ANALYTICAL LETTERS, 2000, 33 (02) : 347 - 356
  • [44] Liquid Chromatographic Enantioseparation of Some Fluoroquinoline Drugs Using Several Polysaccharide-Based Chiral Stationary Phases
    Rebizi, Mohamed Nadjib
    Sekkoum, Khaled
    Belboukhari, Nasser
    Cheriti, Abdelkrim
    Aboul-Enein, Hassan Y.
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2018, 56 (09) : 835 - 845
  • [45] Enantiomeric separation of several oxirane derivatives by high performance liquid chromatography on polysaccharide-based chiral stationary phases
    Zhou, Wei
    Liu, Bing
    Yang, Guo-Sheng
    Koppenhoefer, Bernhard
    Aboul-Enein, Hassan Y.
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2008, 31 (18) : 2879 - 2891
  • [46] Separation of undeuterated and partially deuterated enantioisotopologues of some amphetamine derivatives on achiral and polysaccharide-based chiral columns in high-performance liquid chromatography
    Kobidze, Giorgi
    Sprega, Giorgia
    Daziani, Gloria
    Balloni, Aurora
    Faro, Alfredo Fabrizio Lo
    Farkas, Tivadar
    Peluso, Paola
    Basile, Giuseppe
    Busardo, Francesco Paolo
    Chankvetadze, Bezhan
    JOURNAL OF CHROMATOGRAPHY A, 2024, 1718
  • [47] Use of polysaccharide-based chiral columns: enantiomeric separation of seven pairs of abused drugs by high-performance liquid chromatography–mass spectrometry
    Tajudheen K. Karatt
    Abdul Khader Karakka Kal
    Ramy Sayed
    Jahfar Nalakath
    Zubair Perwad
    Forensic Toxicology, 2019, 37 : 254 - 260
  • [48] Polysaccharide derivatives as useful chiral stationary phases in high-performance liquid chromatography
    Chen, Xiaoming
    Yamamoto, Chiyo
    Okamoto, Yoshio
    PURE AND APPLIED CHEMISTRY, 2007, 79 (09) : 1561 - 1573
  • [49] Direct high-performance liquid chromatography enantioseparation of terazosin on an immobilised polysaccharide-based chiral stationary phase under polar organic and reversed-phase conditions
    Ferretti, Rosella
    Gallinella, Bruno
    La Torre, Francesco
    Zanitti, Leo
    Turchetto, Luciana
    Mosca, Antonina
    Cirilli, Roberto
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (28) : 5385 - 5390
  • [50] High-performance liquid chromatographic enantioseparation of fluorinated cyclic 3-amino acid derivatives on polysaccharide-based chiral stationary phases. Comparison with nonfluorinated counterparts
    Lajko, Gyula
    Orosz, Timea
    Kiss, Lorand
    Forro, Eniko
    Fulop, Ferenc
    Peter, Antal
    Ilisz, Istvan
    BIOMEDICAL CHROMATOGRAPHY, 2016, 30 (09) : 1441 - 1448