An evaluation of Pencil Beam vs Monte Carlo calculations for intracranial stereotactic radiosurgery

被引:0
|
作者
Rembish, Jacob [1 ]
Myers, Pamela [1 ]
Kirby, Neil [1 ]
Saenz, Daniel [1 ]
Rasmussen, Karl [1 ]
Papanikolaou, Nikos [1 ]
Stathakis, Sotirios [1 ]
机构
[1] UT Hlth San Antonio, Dept Radiat Oncol, San Antonio, TX USA
来源
JOURNAL OF BUON | 2020年 / 25卷 / 06期
关键词
SRS; Monte Carlo; Pencilbeam; dose calculation; treatment planning; DOSE DISTRIBUTIONS; LUNG; TUMORS;
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To compare the accuracy of two separate models when calculating dose distributions in patients undergoing stereotactic radiosurgery (SRS) treatment for brain cancer. Methods: For this comparison, two dose calculation algorithms were evaluated on two different treatment planning systems (TPS): Elekta's Monaco Version 5.11.00 Monte Carlo Gold Standard XVMC algorithm and Brainlab's iPlan Pencil Beam algorithm. The DICOM files of 11 patients with a total of 19 targets were exported from iPlan and then imported into Monaco to be recalculated. Using the dose distributions of the original (pencil beam/PB) and recalculated (Monte Carlo/MC) plans, four indices for plan quality were evaluated: coverage (Q), conformity index (CIRTOG), homogeneity index (HI), and gradient index (GI). Results: There was a significant difference in the CIRTOG and HI between the two TPS calculations. However, the magnitude of these differences is often not substantial enough to cause the plan to fall outside of RTOG protocol deviation limits. Only 3 of the 19 targets had CI RTOG values which moved to a new level of deviation, and these targets were unique in terms of size (<0.1 cm(3)). Conclusion: It was found that the difference between systems is often not enough to cause the plan to fall outside of RTOG protocol deviation limits. This is an indication that a PB-based treatment planning system is sufficient for the mostly homogeneous conditions of intracranial SRS planning when the target is larger than 0.1 cm(3). If below 0.1 cm3, the prescribing physician may need to evaluate TPS differences.
引用
收藏
页码:2731 / 2736
页数:6
相关论文
共 50 条
  • [1] Comparison of Monte Carlo and Pencil Beam Algorithms in Brain Dose Calculations for Stereotactic Radiosurgery of Multiple Brain Metastases
    Jiang, H.
    Badkul, R.
    Demez, N.
    Johnson, D.
    Soultan, D.
    Craft, D.
    [J]. MEDICAL PHYSICS, 2021, 48 (06)
  • [2] Is Monte Carlo Necessary for IntraCranial Stereotactic Radiosurgery?
    Rembish, J.
    Saenz, D.
    Mavroidis, P.
    Crownover, R.
    Myers, P.
    Papanikolaou, N.
    Stathakis, S.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E333 - E333
  • [3] Monte Carlo vs. Pencil Beam based optimization of stereotactic lung IMRT
    Sikora, Marcin
    Muzik, Jan
    Soehn, Matthias
    Weinmann, Martin
    Alber, Markus
    [J]. RADIATION ONCOLOGY, 2009, 4
  • [4] Monte Carlo vs. Pencil Beam based optimization of stereotactic lung IMRT
    Marcin Sikora
    Jan Muzik
    Matthias Söhn
    Martin Weinmann
    Markus Alber
    [J]. Radiation Oncology, 4
  • [5] Dosimetric comparison of iPlan® Pencil Beam (PB) and Monte Carlo (MC) algorithms in stereotactic radiosurgery/radiotherapy (SRS/SRT) plans of intracranial arteriovenous malformations
    Menon, Sharika Venugopal
    Paramu, Raghukumar
    Bhasi, Saju
    Gopalakrishnan, Zhenia
    Bhaskaran, Sarin
    Nair, Raghuram Kesavan
    [J]. MEDICAL DOSIMETRY, 2020, 45 (03) : 225 - 234
  • [6] Characterising an electron pencil beam: Monte Carlo vs measurement
    Ebert, M
    Barnes, M
    [J]. MEDICAL PHYSICS, 2005, 32 (06) : 2015 - 2016
  • [7] Pitfalls in the beam modelling process of Monte Carlo calculations for proton pencil beam scanning
    Winterhalter, Carla
    Aitkenhead, Adam
    Oxley, David
    Richardson, Jenny
    Weber, Damien C.
    MacKay, Ranald, I
    Lomax, Antony J.
    Safai, Sairos
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2020, 93 (1107):
  • [8] Monte Carlo Calculations for Radiosurgery of the Clivus
    Ho, A.
    Gibbs, I.
    Chang, S.
    Soltys, S.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 277 - 278
  • [9] Monte Carlo treatment planning for stereotactic radiosurgery
    Solberg, TD
    DeMarco, JJ
    Holly, FE
    Smathers, JB
    DeSalles, AAF
    [J]. RADIOTHERAPY AND ONCOLOGY, 1998, 49 (01) : 73 - 84
  • [10] A Comparison Between Pencil Beam Versus Monte Carlo Calculations in Arc Therapy
    Shin, H.
    Jung, J.
    Kim, M.
    Kay, C.
    Son, S.
    Kang, Y.
    Choi, B.
    Jang, H.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S710 - S710