Performance Comparison of PI and Fuzzy Controller for Indirect Current Control Based Shunt Active Power Filter

被引:0
|
作者
Gotherwal, Niharika [1 ]
Ray, Soumyadeep [1 ]
Gupta, Nitin [1 ]
Saxena, Dipti [1 ]
机构
[1] MNIT Jaipur, Dept Elect Engn, Jaipur, Rajasthan, India
关键词
Power Quality; Active Power Filter; Indirect Current Control (ICC); Fuzzy Logic Control;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The rise of non-linear type of loads, industrial automation has drawn attention towards mitigation of power quality problems and lead to power quality awareness. In this context Shunt active filters efficiently resolve problems caused by current harmonics, improve power factor and compensate reactive power. This paper presents a shunt active power filter which reduces current harmonics in three-phase three-wire system. The performance of conventional PI controller is compared with fuzzy logic controller. The PWM current controlled Voltage Source Converter (VSC) is used as shunt active power filter with hysteresis controller for generating switching pattern. It is observed that the performance of shunt active power filter is superior with indirect current control using active-reactive power theory using fuzzy logic controller. The effective simulation results have been shown for steady state as well as transient conditions.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Experimental Investigation of an Indirect Current Controlled Fuzzy-SVPWM Based Shunt Hybrid Active Power Filter
    Somlal, Jarupula
    Rao, M. Venu Gopala
    Karthikeyan, S. Prabhakar
    [J]. PROCEEDINGS OF THE 2016 IEEE REGION 10 CONFERENCE (TENCON), 2016, : 801 - 806
  • [22] Hierarchical neuro-fuzzy current control for a shunt active power filter
    K. Çağatay Bayındır
    M. Uğraş Cuma
    Mehmet Tümay
    [J]. Neural Computing & Applications, 2006, 15 : 223 - 238
  • [23] Hierarchical neuro-fuzzy current control for a shunt active power filter
    Cagatay Bayindir, K.
    Ugras Cuma, M.
    Tumay, Mehmet
    [J]. NEURAL COMPUTING & APPLICATIONS, 2006, 15 (3-4): : 223 - 238
  • [24] Comparative Performance Analysis of Shunt Active Power Filter and Hybrid Active Power Filter using FPGA-Based Hysteresis Current Controller
    Panda, Gayadhar
    Dash, Santanu Kumar
    Sahoo, Nirjharini
    [J]. 2012 IEEE 5TH INDIA INTERNATIONAL CONFERENCE ON POWER ELECTRONICS (IICPE 2012), 2012,
  • [25] Comparative Study of Direct and Indirect Current Control Algorithms for Shunt Active Power Filter
    Rahman, N. F. A. Abdul
    Nasir, N. Mohd
    Baharom, R.
    [J]. PROCEEDING OF 2019 INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING AND INFORMATICS (ICEEI), 2019, : 324 - 329
  • [26] ADALINE Harmonics Extraction Algorithm applied to a Shunt Active Power Filter based on an Adaptive Fuzzy Hysteresis current control and a fuzzy DC voltage controller
    Khenfar, Noureddine
    Semmah, Abdelhafid
    Kadem, Mohamed
    [J]. PRZEGLAD ELEKTROTECHNICZNY, 2021, 97 (05): : 116 - 121
  • [27] PI vs fractional PI for the control of a shunt active power filter
    Rico, A.
    Milanes, M. I.
    Romero, E.
    Vinagre, B. M.
    [J]. PROCEEDINGS OF THE ASME INTERNATIONAL DESIGN ENGINEERING TECHNICAL CONFERENCES AND COMPUTERS AND INFORMATION IN ENGINEERING CONFERENCE 2007, VOL 5, PTS A-C,, 2008, : 1259 - 1266
  • [29] Current control for a shunt hybrid active power filter using recursive integral PI
    Zhao W.
    Luo A.
    Peng K.
    Deng X.
    [J]. Journal of Control Theory and Applications, 2009, 7 (01): : 77 - 80
  • [30] Comparison of PI and Neural Network based Controllers for Shunt Active Power Filter
    Pedapenki, Kishore Kumar
    Gupta, S. P.
    Pathak, Mukesh Kumar
    [J]. 2015 INTERNATIONAL CONFERENCE ON CONTROL, INSTRUMENTATION, COMMUNICATION AND COMPUTATIONAL TECHNOLOGIES (ICCICCT), 2015, : 214 - 218