Analysis of the association of IL4 polymorphisms with orthodontic mini-implant loss

被引:1
|
作者
Lopes, T. F. [1 ]
Souza, C. M. [1 ]
Reichow, A. M. [1 ]
Melo, A. C. [2 ]
Trevilatto, P. C. [1 ]
机构
[1] Pontificia Univ Catolica Parana, Sch Life Sci, Rua Imaculada Conceicao 1155, BR-80215901 Curitiba, Parana, Brazil
[2] Latin Amer Inst Dent Res & Educ ILAPEO, Curitiba, Parana, Brazil
关键词
orthodontic mini-implant; mini-implant loss; polymorphisms; IL4; SUCCESS RATES; IL-4; GENE; ANCHORAGE; INTERLEUKIN-4; RECEPTOR; SUSCEPTIBILITY; STABILITY; GENOTYPE; DISEASES;
D O I
10.1016/j.ijom.2018.12.008
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The aim of this study was to investigate the association of clinical characteristics and 11,4 tag single nucleotide polymorphisms (SNPs; rs2227284 and rs2243268) with orthodontic mini-implant (MI) failure. The sample included 135 subjects of both sexes, mean age 48.7 +/- 10 years (range 20-76 years): 104 in the control group (patients without any MI loss) and 31 in the study group (patients presenting >= 1 MI loss). Genotypes were determined by real-time PCR. Bivariate and multivariate analyses were performed (P < 0.05). No association was found between the selected tag SNPs and MI loss. The C allele of the 11,4 rs2243268 polymorphism in the recessive model was more frequent in patients who had fewer MIs installed (<= 2 vs. >2; P = 0.043, odds ratio 0.65, 95% confidence interval 0.58-0.74). On multivariate analysis, smoking habit was significantly associated with the group with multiple MIs installed (P = 0.036), however the significance of the association with rs2243268 was not maintained. No association was found between the socio-demographic, smoking, or genetic factors studied and MI loss. This study supports the interaction between host and environmental factors and its influence on susceptibility to orthodontic MI failure.
引用
收藏
页码:982 / 988
页数:7
相关论文
共 50 条
  • [21] A prospective study of factors associated with orthodontic mini-implant survival
    Tsai, Chia-Chun
    Chang, Hong-Po
    Pan, Chin-Yun
    Chou, Szu-Ting
    Tseng, Yu-Chuan
    JOURNAL OF ORAL SCIENCE, 2016, 58 (04) : 515 - 521
  • [22] Bivariate optimization of orthodontic mini-implant thread height and pitch
    Shuning Shen
    Yingying Sun
    Chen Zhang
    Yongjin Yang
    Zhiren Li
    Xingwei Cai
    Yinzhong Duan
    Tao Li
    International Journal of Computer Assisted Radiology and Surgery, 2015, 10 : 109 - 116
  • [23] Primary migration of a mini-implant under a functional orthodontic loading
    Joseph W. Pittman
    Anand Navalgund
    Steve H. Byun
    Hechang Huang
    Albert H. Kim
    Do-Gyoon Kim
    Clinical Oral Investigations, 2014, 18 : 721 - 728
  • [24] Systematic review of mini-implant displacement under orthodontic loading
    Manuel Nienkemper
    Jrg Handschel
    Dieter Drescher
    International Journal of Oral Science, 2014, 6 (01) : 1 - 6
  • [25] Mechanical influence of thread pitch on orthodontic mini-implant stability
    da Cunha, Amanda Carneiro
    Ayres de Freitas, Amanda Osorio
    Marquezan, Mariana
    Nojima, Lincoln Issamu
    BRAZILIAN ORAL RESEARCH, 2015, 29 (01): : 1 - 6
  • [26] Systematic review of mini-implant displacement under orthodontic loading
    Manuel Nienkemper
    Jrg Handschel
    Dieter Drescher
    International Journal of Oral Science, 2014, (01) : 1 - 6
  • [27] Prevalence and cause of mini-implant failure encountered by orthodontic residents
    Sreenivasagan S.
    Subramanian A.K.
    Rengalakshmi S.
    Journal of Long-Term Effects of Medical Implants, 2021, 31 (04) : 1 - 4
  • [28] Effects of surface treatment on the osseointegration potential of orthodontic mini-implant
    Jeon, Mi-Sun
    Kang, Yoon-Goo
    Mo, Sung-Seo
    Lee, Keun-Hye
    Kook, Yoon-Ah
    Kim, Seong-Hun
    KOREAN JOURNAL OF ORTHODONTICS, 2008, 38 (05) : 328 - 336
  • [29] Bone thickness of the palate for orthodontic mini-implant anchorage in adults
    Kang, Sungmin
    Lee, Shin-Jae
    Ahn, Sug-Joon
    Heo, Min-Suk
    Kim, Tae-Woo
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2007, 131 (04) : S74 - S81
  • [30] Orthodontic Mini-Implant Stability under Continuous or Intermittent Loading: A Histomorphometric and Biomechanical Analysis
    Wu, Yeke
    Xu, Zhenrui
    Tan, Luyuan
    Tan, Lijun
    Zhao, Zhihe
    Yang, Pu
    Li, Yu
    Tang, Tian
    Zhao, Lixing
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2015, 17 (01) : 163 - 172