Advanced Virtual Monochromatic Images from Dual Source Dual-Energy CT for a Reduction in the Contrast Medium Dose (389 mgI/kg) in Multiphase Liver CT: Evaluation of Image Quality and Focal Lesion Conspicuity

被引:1
|
作者
Kim, Ji Eun [1 ]
Kim, Hyun Ok [2 ,3 ]
Bae, Kyungsoo [1 ]
Cho, Jae Min [1 ]
Choi, Ho Cheol [1 ]
Choi, Dae Seob [1 ]
Na, Jaebeom [1 ]
机构
[1] Gyeongsang Natl Univ, Gyeongsang Natl Univ Hosp, Dept Radiol, Coll Med, Jinju, South Korea
[2] Gyeongsang Natl Univ, Coll Med, Dept Internal Med, 79 Gangnam Ro, Jinju 52727, South Korea
[3] Gyeongsang Natl Univ Hosp, Jinju, South Korea
关键词
Contrast Medium; Computed Tomography; Dual-Energy; Virtual Monochromatic Image; LOW TUBE VOLTAGE; ITERATIVE RECONSTRUCTION ALGORITHM; ABDOMINAL CT; DYNAMIC CT; AGENT; NOISE; SELECTION; PROTOCOL; SIZE; MDCT;
D O I
10.5812/iranjradiol.83014
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Low-energy advanced virtual monochromatic images (VMIs) from dual source dual-energy CT(DSCT) could be applied to reduce contrast medium dose due to superior iodine contrast-to-noise ratios (CNRs). Objectives: To investigate feasibility of advanced VMIs from DSCT to reduce contrast medium dose in multiphase liver CT without impairing image quality and conspicuity of focal hepatic lesions (FHLs). Patients and Methods: Ninety-four patients with 110 FHL5 underwent follow-up CT twice prospectively with different protocols: protocol A, conventional 100 kVp and 555 mgI/kg; protocol B, dual-energy mode and 389 mgI/kg. The signal-to-noise ratio (SNR) and lesion-to-liver CNR were compared between the VMIs (40 -120 keV,10-keV interval) reconstructed using advanced image-based algorithm and conventional images. Two radiologists qualitatively evaluated VMIs, compared with the 100 kVp images, using a six-point scale. Results: The SNRs of pancreas, aorta, portal and hepatic vein were similar to those at 100 kVp images (P > 0.05) at 40-50 key images during late arterial phase (LAP) and at 40-60 key images during portal venous phase (PVP) except for the SNRs of aorta and veins at 40 key images which were significantly higher (P < 0.0109) during both phases and PVP, respectively. The CNR of 56 hypervascular FHLs was significantly higher at 40 - 50 keV images (P < 0.0002) and was similar at 60 keV images (P > 0.05) during LAP. The CNR of 58 hypovascular FHLs was similar at 40 -120 key images (P > 0.05) during PVP. Among the VMIs, 50 keV and 50 - 60 keV images received the highest scores (P < 0.0315 and P < 0.0041) by both reviewers during LAP and PVP, respectively. Conclusion: Advanced 50 - 60 keV images from DSCT allowed contrast dose reduction by 30% in multiphase liver CT without impairing image quality and conspicuity of FHL5, compared with the conventional 100 kVp images with 555 mgI/kg.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Reduced-iodine-dose dual-energy coronary CT angiography: qualitative and quantitative comparison between virtual monochromatic and polychromatic CT images
    Rotzinger, David C.
    Si-Mohamed, Salim A.
    Yerly, Jerome
    Boccalini, Sara
    Becce, Fabio
    Boussel, Loic
    Meuli, Reto A.
    Qanadli, Salah D.
    Douek, Philippe C.
    EUROPEAN RADIOLOGY, 2021, 31 (09) : 7132 - 7142
  • [22] Reduced-iodine-dose dual-energy coronary CT angiography: qualitative and quantitative comparison between virtual monochromatic and polychromatic CT images
    David C. Rotzinger
    Salim A. Si-Mohamed
    Jérôme Yerly
    Sara Boccalini
    Fabio Becce
    Loïc Boussel
    Reto A. Meuli
    Salah D. Qanadli
    Philippe C. Douek
    European Radiology, 2021, 31 : 7132 - 7142
  • [23] Trends in radiation dose and image quality for pediatric patients with a multidetector CT and a third-generation dual-source dual-energy CT
    Andrea Agostini
    Alberto Mari
    Cecilia Lanza
    Nicolo’ Schicchi
    Alessandra Borgheresi
    Stefania Maggi
    Andrea Giovagnoni
    La radiologia medica, 2019, 124 : 745 - 752
  • [24] Trends in radiation dose and image quality for pediatric patients with a multidetector CT and a third-generation dual-source dual-energy CT
    Agostini, Andrea
    Mari, Alberto
    Lanza, Cecilia
    Schicchi, Nicolo
    Borgheresi, Alessandra
    Maggi, Stefania
    Giovagnoni, Andrea
    RADIOLOGIA MEDICA, 2019, 124 (08): : 745 - 752
  • [25] Possible Contrast Media Reduction with Low keV Monoenergetic Images in the Detection of Focal Liver Lesions: A Dual-Energy CT Animal Study
    Chung, Yong Eun
    You, Je Sung
    Lee, Hye-Jeong
    Lim, Joon Seok
    Lee, Hye Sun
    Baek, Song-Ee
    Kim, Myeong-Jin
    PLOS ONE, 2015, 10 (07):
  • [26] Split-bolus CT-urography using dual-energy CT: Feasibility, image quality and dose reduction
    Takeuchi, Mitsuru
    Kawai, Tatsuya
    Ito, Masato
    Ogawa, Masaki
    Ohashi, Kazuya
    Hara, Masaki
    Shibamoto, Yuta
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (11) : 3160 - 3165
  • [27] Evaluation of Virtual Non-Contrast Images From a Novel Split-Filter Dual-Energy CT Technique
    Huang, J.
    Szczykutowicz, T.
    Bayouth, J.
    Miller, J.
    MEDICAL PHYSICS, 2016, 43 (06) : 3877 - 3877
  • [28] Comparison of Image Quality and Radiation Dose Between Single-Energy and Dual-Energy Images for the Brain With Stereotactic Frames on Dual-Energy Cerebral CT
    Zhao, Xiaojing
    Chao, Wang
    Shan, Yi
    Li, Jingkai
    Zhao, Cheng
    Zhang, Miao
    Lu, Jie
    FRONTIERS IN RADIOLOGY, 2022, 2
  • [29] Image Quality of Virtual Noncontrast Images Derived from Dual-energy CT Angiography after Endovascular Aneurysm Repair
    Sommer, Wieland H.
    Graser, Anno
    Becker, Christoph R.
    Clevert, Dirk A.
    Reiser, Maximilian F.
    Nikolaou, Konstantin
    Johnson, Thorsten R. C.
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2010, 21 (03) : 315 - 321
  • [30] Virtual monoenergetic images from dual-energy CT: systematic assessment of task-based image quality performance
    Cester, Davide
    Eberhard, Matthias
    Alkadhi, Hatem
    Euler, Andre
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2022, 12 (01) : 726 - +