Threshold contrast visibility of micro calcifications in digital mammography

被引:0
|
作者
Carton, AK [1 ]
Bosmans, H [1 ]
Vandenbroucke, D [1 ]
Van Ongeval, C [1 ]
Souverijns, G [1 ]
Rogge, F [1 ]
Marchal, G [1 ]
机构
[1] Catholic Univ Louvain Hosp, Dept Radiol, B-3000 Louvain, Belgium
关键词
simulation; micro calcifications; phantom; digital mammography; observer study;
D O I
10.1117/12.536298
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study is to describe a method that allows the calculation of a contrast-detail curve for a particular system configuration using simulated micro calcifications into clinical mammograms. We made use of simulated templates of micro calcifications and adjusted their x-ray transmission coefficients and resolution to the properties of the mammographic system under consideration (4). We expressed the thickness of the simulated micro calcifications in terms of Al equivalence. In a first step we validated that the thickness of very small Al particles with well known size and thickness can be calculated from their x-ray transmission characteristics at a particular X-ray beam energy. Then, micro calcifications with equivalent diameters in the plane of the detector ranging from 300 to 800 mum and thicknesses, expressed in Al equivalent, covering 77 to 800 mum were simulated into the raw data of real clinical images. The procedure was tested on 2 system configurations: the GE Senographe 2000 D and the Se based Agfa Embrace DM1000 system. We adapted the X-ray transmissions and spatial characteristics of the simulated micro calcifications such that the same physical micro calcification could be simulated into images with the specific exposure parameters (Senographe 2000D: 28 kVp-Rh/Rh, Embrace DM1000: 28 kVp-Mo/Rh), compressed breast thickness (42+/-5mm) and detector under consideration. After processing and printing, 3 observers scored the visibility of the micro calcifications. We derived contrast-detail curves. This psychophysical method allows to summarize the performance of a digital mammography detector including processing and visualization.
引用
收藏
页码:770 / 779
页数:10
相关论文
共 50 条
  • [31] Contrast enhanced digital mammography - a useful adjuvant to digital mammography in predicting tumour size
    McGuire, A.
    O'Leary, D. P.
    Ryan, M.
    Khan, Z.
    Corrigan, M.
    Redmond, H. P.
    Relihan, N.
    BRITISH JOURNAL OF SURGERY, 2015, 102 : 22 - 23
  • [32] Indicator and calibration material for micro calcifications in dual-energy mammography
    Chen, Xi
    Men, Xuanqin
    Zhang, Lei
    MEDICAL BIOMETRICS, PROCEEDINGS, 2007, 4901 : 265 - +
  • [33] Three-dimensional simulation of breast calcifications for applications in digital mammography
    Nappi, J
    Dean, PB
    Nevalainen, O
    CAR '98 - COMPUTER ASSISTED RADIOLOGY AND SURGERY, 1998, 1165 : 230 - 235
  • [34] Algorithmic 3D simulation of breast calcifications for digital mammography
    Näppi, J
    Dean, PB
    Nevalainen, O
    Toikkanen, S
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2001, 66 (01) : 115 - 124
  • [35] Digital Breast Tomosynthesis With Synthetic Mammography: Are We Missing Calcifications That Matter?
    Nguyen, Adrien
    Mirchandani, Anicia
    Joseph, Sumita
    Mapkar, Zaiba
    Singh, Evita
    JOURNAL OF BREAST IMAGING, 2023, 5 (06) : 666 - 674
  • [36] Evaluation of contrast-enhanced digital mammography
    Diekmann, Felix
    Freyer, Martin
    Diekmann, Susanne
    Fallenberg, Eva M.
    Fischer, Thomas
    Bick, Ulrich
    Poellinger, Alexander
    EUROPEAN JOURNAL OF RADIOLOGY, 2011, 78 (01) : 112 - 121
  • [37] Contrast enhancement by digital equalization (CEDE) in mammography
    Huda, W
    Levin, G
    Ogden, K
    Scalzetti, E
    MEDICAL PHYSICS, 2002, 29 (06) : 1308 - 1308
  • [38] Evaluation of microcalcification contrast in clinical images for digital mammography and synthetic mammography
    Baldelli, P.
    Cardarelli, P.
    Flanagan, F.
    Maguire, S.
    Phelan, N.
    Tomasi, S.
    Taibi, A.
    EUROPEAN JOURNAL OF RADIOLOGY, 2021, 140
  • [39] Contrast study of CdZnTe detectors for digital mammography
    Giakos, G.C.
    Pillai, B.
    Chowdhury, S.
    Vedantham, S.
    Dasgupta, A.
    Sheffer, D.B.
    Davros, W.J.
    Passalaqua, A.
    Endorf, R.J.
    Journal of X-Ray Science and Technology, 1997, 7 (3-4): : 317 - 326
  • [40] Contrast-enhanced digital mammography and angiogenesis
    Rosado-Mendez, I.
    Palma, B. A.
    Villasenor, Y.
    Benitez-Bribiesca, L.
    Brandan, M. E.
    NUCLEAR PHYSICS METHODS AND ACCELERATORS IN BIOLOGY AND MEDICINE, 2007, 958 : 278 - +