ADC measurements on the Unity MR-linac - A recommendation on behalf of the Elekta Unity MR-linac consortium

被引:58
|
作者
Kooreman, Ernst S. [1 ]
van Houdt, Petra J. [1 ]
Keesman, Rick [1 ]
Pos, Floris J. [1 ]
van Pelt, Vivian W. J. [1 ]
Nowee, Marlies E. [1 ]
Wetscherek, Andreas [2 ]
Tijssen, Rob H. N. [3 ]
Philippens, Marielle E. P. [3 ]
Thorwarth, Daniela [4 ]
Wang, Jihong [5 ]
Shukla-Dave, Amita [6 ]
Hall, William A. [7 ]
Paulson, Eric S. [7 ]
van der Heide, Uulke A. [1 ]
机构
[1] Netherlands Canc Inst, Dept Radiat Oncol, Amsterdam, Netherlands
[2] Royal Marsden NHS Fdn Trust, Inst Canc Res, Joint Dept Phys, London, England
[3] Univ Med Ctr Utrecht, Dept Radiotherapy, Utrecht, Netherlands
[4] Univ Tubingen, Dept Radiat Oncol, Sect Biomed Phys, Tubingen, Germany
[5] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
[6] Mem Sloan Kettering Canc Ctr, Dept Med Phys, New York, NY 10021 USA
[7] Med Coll Wisconsin, Dept Radiat Oncol, Milwaukee, WI 53226 USA
关键词
MR-linac; Diffusion weighted imaging; DWI; ADC; Recommendation; APPARENT DIFFUSION-COEFFICIENT; IN-VIVO; RADIOTHERAPY; REPEATABILITY; PERFUSION; PROSTATE; CANCER;
D O I
10.1016/j.radonc.2020.09.046
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: Diffusion-weighted imaging (DWI) for treatment response monitoring is feasible on hybrid magnetic resonance linear accelerator (MR-linac) systems. The MRI scanner of the Elekta Unity system has an adjusted design compared to diagnostic scanners. We investigated its impact on measuring the DWI-derived apparent diffusion coefficient (ADC) regarding three aspects: the choice of b-values, the spatial variation of the ADC, and scanning during radiation treatment. The aim of this study is to give recommendations for accurate ADC measurements on Unity systems. Materials and methods: Signal-to-noise ratio (SNR) measurements with increasing b-values were done to determine the highest bvalue that can be measured reliably. The spatial variation of the ADC was assessed on six Unity systems with a cylindrical phantom of 40 cm diameter. The influence of gantry rotation and irradiation was investigated by acquiring DWI images before and during treatment of 11 prostate cancer patients. Results: On the Unity system, a maximum b-value of 500 s/mm(2) should be used for ADC quantification, as a trade-off between SNR and diffusion weighting. Accurate ADC values were obtained within 7 cm from the iso-center, while outside this region ADC values deviated more than 5%. The ADC was not influenced by the rotating linac or irradiation during treatment. Conclusion: We provide Unity system specific recommendations for measuring the ADC. This will increase the consistency of ADC values acquired in different centers on the Unity system, enabling large cohort studies for biomarker discovery and treatment response monitoring. (C) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页码:106 / 113
页数:8
相关论文
共 50 条
  • [1] Commissioning measurements on an Elekta Unity MR-Linac
    Powers, Marcus
    Baines, John
    Crane, Robert
    Fisher, Chantelle
    Gibson, Stephen
    Marsh, Linda
    Oar, Bronwyn
    Shoobridge, Ariadne
    Simpson-Page, Emily
    Van der Walt, Marchant
    de Vine, Glenn
    [J]. PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2022, 45 (02) : 457 - 473
  • [2] Commissioning measurements on an Elekta Unity MR-Linac
    Marcus Powers
    John Baines
    Robert Crane
    Chantelle Fisher
    Stephen Gibson
    Linda Marsh
    Bronwyn Oar
    Ariadne Shoobridge
    Emily Simpson-Page
    Marchant Van der Walt
    Glenn de Vine
    [J]. Physical and Engineering Sciences in Medicine, 2022, 45 : 457 - 473
  • [3] Adaptive radiotherapy: The Elekta Unity MR-linac concept
    Winkel, Dennis
    Bol, Gijsbert H.
    Kroon, Petra S.
    van Asselen, Bram
    Hackett, Sara S.
    Werensteijn-Honingh, Anita M.
    Intven, Martijn P. W.
    Eppinga, Wietse S. C.
    Tijssen, Rob H. N.
    Kerkmeijer, Linda G. W.
    de Boer, Hans C. J.
    Mook, Stella
    Meijer, Gert J.
    Hes, Jochem
    Willemsen-Bosman, Mirjam
    de Groot-van Breugel, Eline N.
    Jurgenliemk-Schulz, Ina M.
    Raaymakers, Bas W.
    [J]. CLINICAL AND TRANSLATIONAL RADIATION ONCOLOGY, 2019, 18 : 54 - 59
  • [4] Developing a QA programme for the Elekta Unity MR-linac
    Chick, J.
    Hanson, I.
    Nill, S.
    Oelfke, U.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S1167 - S1168
  • [5] Machine QA for the Elekta Unity system: A Report from the Elekta MR-linac consortium
    Roberts, David A.
    Sandin, Carlos
    Vesanen, Panu T.
    Lee, Hannah
    Hanson, Ian M.
    Nill, Simeon
    Perik, Thijs
    Lim, Seng Boh
    Vedam, Sastry
    Yang, Jinzhong
    Woodings, Simon W.
    Wolthaus, Jochem W. H.
    Keller, Brian
    Budgell, Geoff
    Chen, Xinfeng
    Li, X. Allen
    [J]. MEDICAL PHYSICS, 2021, 48 (05) : E67 - E85
  • [6] Elekta Unity MR-linac commissioning: mechanical and dosimetry tests
    Tsuneda, Masato
    Abe, Kota
    Fujita, Yukio
    Ikeda, Yohei
    Furuyama, Yoshinobu
    Uno, Takashi
    [J]. JOURNAL OF RADIATION RESEARCH, 2023, 64 (01) : 73 - 84
  • [7] Feasibility of spinal stereotactic body radiotherapy in Elekta Unity® MR-Linac
    Han, Eun Young
    Aima, Manik
    Hughes, Neil
    Briere, Tina M.
    Yeboa, Debra N.
    Castillo, Pam
    Wang, Jihong
    Yang, Jinzhong
    Vedam, Sastry
    [J]. JOURNAL OF RADIOSURGERY AND SBRT, 2020, 7 (02): : 127 - 134
  • [8] Secondary MU Check Using RadCalc for Elekta Unity MR-Linac
    Yang, J.
    Vedam, S.
    Brink, C.
    Nielsen, M.
    Ji, M.
    Bist, L.
    Ohrt, J.
    Wang, J.
    Balter, P.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E267 - E267
  • [9] Use of an a-Si EPID for routine QC of the Elekta Unity MR-Linac
    Berresford, J.
    Agnew, J.
    Harriden, T.
    Budgell, G.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S1159 - S1160
  • [10] An Independent Dose Calculation Method for MR-Guided Radiotherapy with Elekta Unity MR-Linac
    Chen, X.
    Hwang, M.
    Oh, S.
    Sohn, J.
    [J]. MEDICAL PHYSICS, 2022, 49 (06) : E208 - E208