Comparison of conventional and CT-based planning for intracavitary brachytherapy for cervical cancer: target volume coverage and organs at risk doses

被引:45
|
作者
Onal, Cem [1 ]
Arslan, Gungor [1 ]
Topkan, Erkan [1 ]
Pehlivan, Berrin [1 ]
Yavuz, Melek [1 ]
Oymak, Ezgi [1 ]
Yavuz, Aydin [1 ]
机构
[1] Baskent Univ, Fac Med, Dept Radiat Oncol, Adana, Turkey
来源
JOURNAL OF EXPERIMENTAL & CLINICAL CANCER RESEARCH | 2009年 / 28卷
关键词
REFERENCE-POINT; WORKING GROUP; RECTUM; BLADDER; IMAGE; CARCINOMA; RADIOTHERAPY; HISTOGRAMS; RECOMMENDATIONS; TRANSVERSE;
D O I
10.1186/1756-9966-28-95
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: To compare intracavitary brachytherapy (ICBT) planning methods for cervical cancer, based on either orthogonal radiographs (conventional plan) or CT sections (CT plan); the comparison focused on target volume coverage and dose volume analysis of organs at risk (OARs), by representing point doses defined by the International Commission on Radiation Units and Measurement (ICRU) and dose volume histograms (DVHs) from 3D planning. Methods: We analyzed the dosimetric data for 62 conventional and CT-based ICBT plans. The gross tumor volume (GTV), clinical target volume (CTV) and organs at risk (OAR)s were contoured on the CT-plan. Point A and ICRU 38 rectal and bladder points were defined on reconstructed CT images. Results: Patients were categorized on the basis of whether the >95% isodose line of the point-A prescription dose encompassed the CTV (group 1, n = 24) or not (group 2, n = 38). The mean GTV and CTV (8.1 cc and 20.6 cc) were smaller in group 1 than in group 2 (24.7 cc and 48.4 cc) (P<0.001). The mean percentage of GTV and CTV coverage with the 7 Gy isodose was 93.1% and 88.2% for all patients, and decreased with increasing tumor size and stage. The mean D2 and D5 rectum doses were 1.66 and 1.42 times higher than the corresponding ICRU point doses and the mean D2 and D5 bladder doses were 1.51 and 1.28 times higher. The differences between the ICRU dose and the D2 and D5 doses were significantly higher in group 2 than in group 1 for the bladder, but not for the rectum. Conclusion: The CT-plan is superior to the conventional plan in target volume coverage and appropriate evaluation of OARs, as the conventional plan overestimates tumor doses and underestimates OAR doses.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] CONVENTIONAL POINT A AND CT BASED INDIVIDUAL TREATMENT PLANNING FOR BRACHYTHERAPY OF CERVICAL CANCER
    Wanderas, A.
    Sundset, M.
    Langdal, I.
    Danielsen, S.
    Marthinsen, A. B.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S298 - S298
  • [22] Computed tomography (CT)-based 3-D treatment planning for intracavitary brachytherapy in cancer of the cervix: dose-volume histograms of the tumor and organs at risk
    Kim, R
    Robert, K
    Duan, J
    Shen, S
    RADIOTHERAPY AND ONCOLOGY, 2004, 73 : S19 - S19
  • [23] Investigation of whether in-room CT-based adaptive intracavitary brachytherapy for uterine cervical cancer is robust against interfractional location variations of organs and/or applicators
    Oku, Yoshifumi
    Arimura, Hidetaka
    Tran Thi Thao Nguyen
    Hiraki, Yoshiyuki
    Toyota, Masahiko
    Saigo, Yasumasa
    Yoshiura, Takashi
    Hirata, Hideki
    JOURNAL OF RADIATION RESEARCH, 2016, 57 (06) : 677 - 683
  • [24] Comparison of CT and MRI-Based Clinical Target Volume Contours at the Time of Brachytherapy for Cervical Cancer
    Swanick, C. W.
    Castle, K. O.
    Vedam, S.
    Turner, L. M.
    Yang, J.
    Rauch, G. M.
    Jhingran, A.
    Eifel, P. J.
    Klopp, A. H.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (03): : E282 - E282
  • [25] A comparison of organs at risk doses in GYN intracavitary brachytherapy for different tandem lengths and bladder volumes
    Siavashpour, Zahra
    Aghamiri, Mahmoud Reza
    Jaberi, Ramin
    ZareAkha, Naser
    Manshadi, Hamid Reza Dehghan
    Kirisits, Christian
    Sedaghat, Mahbod
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (03): : 5 - 13
  • [26] Evaluation of variation in dose of organs at risk in intracavitary brachytherapy of cervical cancer - a prospective study
    Sharma, Brahmacharimayum Arunkumar
    Singh, Tomcha
    Singh, L. Jaichand
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2011, 3 (01) : 23 - 25
  • [27] Investigation of Impact of Systematic Errors in Applicator Reconstruction On Doses of Organs at Risk and Target Volumes in Intracavitary Brachytherapy
    Singh, G.
    Mourya, A.
    Singh, B.
    Thaper, D.
    Kamal, R.
    Oinam, A.
    Kumar, V.
    Rai, B.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [28] Differences Between MRI- and CT-Based Delineation of Target Volume and Organs at Risk in High-Dose-Rate Brachytherapy of Cervix
    Ramya, Rangarajan
    Saravanan, S.
    Vijayalakshmi, J.
    Kumari, K.
    INDIAN JOURNAL OF GYNECOLOGIC ONCOLOGY, 2019, 17 (03)
  • [29] Differences Between MRI- and CT-Based Delineation of Target Volume and Organs at Risk in High-Dose-Rate Brachytherapy of Cervix
    Rangarajan Ramya
    S. Saravanan
    J. Vijayalakshmi
    K. Kumari
    Indian Journal of Gynecologic Oncology, 2019, 17
  • [30] CT-based HDR brachytherapy for cervical cancer: Correlation between dose volume parameters and telangiectasia
    Koom, W.
    Sohn, D.
    Park, S.
    Kim, J.
    Kim, D.
    Shin, K.
    Cho, K.
    Kim, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S400 - S400