Dry contact electrodes performance in canine ECG

被引:2
|
作者
Virtanen, Juhani [1 ,2 ]
Leivo, Joni [1 ,2 ]
Vehkaoja, Antti [1 ,2 ]
Somppi, Sanni [3 ]
Tornqvist, Heini [3 ]
Fiedler, Patrique [4 ]
Vaataja, Heli [5 ]
Surakka, Veikko [5 ]
机构
[1] Univ Tampere, BioMediTech Inst, Tampere, Finland
[2] Univ Tampere, Fac Biomed Sci & Engn, Tampere, Finland
[3] Univ Helsinki, Dept Equine & Small Anim Med, Helsinki, Finland
[4] Tech Univ Ilmenau, Inst Biomed Engn & Informat, Ilmenau, Germany
[5] Univ Tampere UTA, Res Grp Emot Social & Comp, Fac Commun Sci, Tampere, Finland
关键词
Canine; Electrocardiogram; Dry Electrode; HEART-RATE-VARIABILITY;
D O I
10.1145/3295598.3295609
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Measuring the heart rate of animals is an important area of research which can be applied to numerous analyses. In this work we evaluate the performance of two dry contact electrocardiogram (ECG) electrode structures for monitoring the heart rate of domestic pets. The aim was to improve the operation of previously evaluated electrodes with some modifications. First, the thirty-pins of a previously studied polymer electrode with a silver/silver chloride (Ag/AgCl) coating were reduced to 12. Second, a 12-pin gold-plated metal electrode was coated with poly (3,4 ethylenedioxythiophene) polystyrene sulfonate (PEDOT: PSS). These electrodes were attached to a specifically designed measurement harness and the performance of the electrodes was evaluated in terms of heartbeat detection coverage. The heart rate coverage was measured during four different behaviors: standing, sitting, lying, and walking (N=27/activity). The results were, in general, comparable to the previously reported performance but having fewer pins on a polymer electrode seemed to cause more variation in the coverage values. However, when measures such as the median value of the coverages are considered, there was no obvious difference, especially when the coverage values were observed altogether. Thus, new electrode solutions are worthy of further research.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Noise performance of textile-based dry ECG recording electrodes
    Maji, Soumyajyoti
    Burke, Martin J.
    ELECTRONICS LETTERS, 2021, 57 (02) : 45 - 48
  • [2] Novel dry electrodes for ECG monitoring
    Gruetzmann, Anna
    Hansen, Stefan
    Mueller, Joerg
    PHYSIOLOGICAL MEASUREMENT, 2007, 28 (11) : 1375 - 1390
  • [3] A Low-Power Portable ECG Touch Sensor with Two Dry Metal Contact Electrodes
    Yan, Long
    Yoo, Hoi-Jun
    JOURNAL OF SEMICONDUCTOR TECHNOLOGY AND SCIENCE, 2010, 10 (04) : 300 - 308
  • [4] Contact ECG Recording Using Copper and E-Textile Based Flexible Dry Electrodes
    Ren, Kai
    Ma, Ruyu
    Nikkhah, Mohammad R.
    Eggleston, Steve
    Ren, Yu-Jiun
    Behdad, Nader
    PROGRESS IN ELECTROMAGNETICS RESEARCH M, 2021, 101 : 47 - 58
  • [5] Contact ecg recording using copper and e-textile based flexible dry electrodes
    Ren K.
    Ma R.
    Nikkhah M.R.
    Eggleston S.
    Ren Y.-J.
    Behdad N.
    Progress In Electromagnetics Research M, 2021, 101 : 47 - 58
  • [6] LOW-NOISE AND COST-EFFECTIVE ACTIVE ELECTRODES FOR DRY CONTACT ECG APPLICATIONS
    Voropai, A.
    Sarana, V
    SCIENCE AND INNOVATION, 2022, 18 (01): : 112 - 123
  • [7] Development of printed and flexible dry ECG electrodes
    Chlaihawi, Amer Abdulmahdi
    Narakathu, Binu Baby
    Emamian, Sepehr
    Bazuin, Bradley J.
    Atashbar, Massood Z.
    SENSING AND BIO-SENSING RESEARCH, 2018, 20 : 9 - 15
  • [8] Electrical Characterisation of Dry Electrodes for ECG Recording
    Baba, A.
    Burke, M. J.
    PROCEEDINGS OF THE 12TH WSEAS INTERNATIONAL CONFERENCE ON CIRCUITS: NEW ASPECTS OF CIRCUITS, 2008, : 76 - +
  • [9] Performance Evaluation of Woven Conductive Dry Textile Electrodes for Continuous ECG Signals Acquisition
    Rajanna, Rama Reddy
    Sriraam, Natarajan
    Vittal, Prabhu Ravikala
    Arun, Uma
    IEEE SENSORS JOURNAL, 2020, 20 (03) : 1573 - 1581
  • [10] Contact dermatitis to self-adhesive ECG electrodes
    Ruehlemann, David
    Kuegler, Katrin
    Mydlach, Birgit
    Frosch, Peter J.
    CONTACT DERMATITIS, 2010, 62 (05) : 314 - 315