Hydrophilic Fluorescent Nanogel Thermometer for Intracellular Thermometry

被引:443
|
作者
Gota, Chie [1 ]
Okabe, Kohki [1 ,2 ]
Funatsu, Takashi [1 ,3 ]
Harada, Yoshie [2 ]
Uchiyama, Seiichi [1 ]
机构
[1] Univ Tokyo, Grad Sch Pharmaceut Sci, Bunkyo Ku, Tokyo 1130033, Japan
[2] Tokyo Metropolitan Inst Med Sci, Bunkyo Ku, Tokyo 1138613, Japan
[3] Univ Tokyo, Ctr NanoBio Integrat, Bunkyo Ku, Tokyo 1138656, Japan
关键词
SINGLE LIVING CELLS; TEMPERATURE-MEASUREMENT; PHASE-TRANSITIONS; THERMOGENESIS; MICROGELS; POLYMERS; POLARITY; PROBES; VOLUME; HEAT;
D O I
10.1021/ja807714j
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The first methodology to measure intracellular temperature is described. A highly hydrophilic fluorescent nanogel thermometer developed for this purpose stays in the cytoplasm and emits stronger fluorescence at a higher temperature. Thus, intracellular temperature variations associated with biological processes can be monitored by this novel thermometer with a temperature resolution of better than 0.5 degrees C.
引用
收藏
页码:2766 / +
页数:3
相关论文
共 50 条
  • [1] Temperature Measurement in Single Living Cells using a Hydrophilic Fluorescent Nanogel Thermometer
    Okabe, Kohki
    Uchiyama, Seiichi
    Harada, Yoshie
    Funatsu, Takashi
    [J]. BIOPHYSICAL JOURNAL, 2012, 102 (03) : 198A - 198A
  • [2] A Ratiometric Organic Fluorescent Nanogel Thermometer for Highly Sensitive Temperature Sensing
    Wang, Chao
    Zhao, Xianhao
    Wu, Kaiyu
    Lv, Shuyi
    Zhu, Chunlei
    [J]. BIOSENSORS-BASEL, 2022, 12 (09):
  • [3] A Nanogel for Ratiometric Fluorescent Sensing of Intracellular pH Values
    Peng, Hong-shang
    Stolwijk, Judith A.
    Sun, Li-Ning
    Wegener, Joachim
    Wolfbeis, Otto S.
    [J]. ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2010, 49 (25) : 4246 - 4249
  • [4] Intracellular thermometry with fluorescent sensors for thermal biology
    Okabe, Kohki
    Sakaguchi, Reiko
    Shi, Beini
    Kiyonaka, Shigeki
    [J]. PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 2018, 470 (05): : 717 - 731
  • [5] Intracellular thermometry with fluorescent sensors for thermal biology
    Kohki Okabe
    Reiko Sakaguchi
    Beini Shi
    Shigeki Kiyonaka
    [J]. Pflügers Archiv - European Journal of Physiology, 2018, 470 : 717 - 731
  • [6] Intracellular Thermometry by Using Fluorescent Gold Nanoclusters
    Shang, Li
    Stockmar, Florian
    Azadfar, Naghmeh
    Nienhaus, G. Ulrich
    [J]. ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2013, 52 (42) : 11154 - 11157
  • [7] Intracellular temperature sensing by a ratiometric fluorescent polymer thermometer
    Qiao, Juan
    Chen, Chuanfang
    Qi, Li
    Liu, Meirong
    Dong, Ping
    Jiang, Qin
    Yang, Xinzheng
    Mu, Xiaoyu
    Mao, Lanqun
    [J]. JOURNAL OF MATERIALS CHEMISTRY B, 2014, 2 (43) : 7544 - 7550
  • [8] A cationic fluorescent polymeric thermometer for the ratiometric sensing of intracellular temperature
    Uchiyama, Seiichi
    Tsuji, Toshikazu
    Ikado, Kumiko
    Yoshida, Aruto
    Kawamoto, Kyoko
    Hayashi, Teruyuki
    Inada, Noriko
    [J]. ANALYST, 2015, 140 (13) : 4498 - 4506
  • [9] Bias in Intracellular Luminescence Thermometry: The Case of the Green Fluorescent Protein
    Rodriguez-Sevilla, Paloma
    Spicer, Graham
    Sagrera, Ana
    Adam, Alejandro P.
    Efeyan, Alejo
    Jaque, Daniel
    Thompson, Sebastian A.
    [J]. ADVANCED OPTICAL MATERIALS, 2023, 11 (11)
  • [10] Mitochondria-targeted fluorescent thermometer monitors intracellular temperature gradient
    Arai, Satoshi
    Suzuki, Madoka
    Park, Sung-Jin
    Yoo, Jung Sun
    Wang, Lu
    Kang, Nam-Young
    Ha, Hyung-Ho
    Chang, Young-Tae
    [J]. CHEMICAL COMMUNICATIONS, 2015, 51 (38) : 8044 - 8047