X-ray detector calibration in the PTB radiometry laboratory at the electron storage ring BESSY II

被引:41
|
作者
Beckhoff, B [1 ]
Klein, R [1 ]
Krumrey, M [1 ]
Scholze, F [1 ]
Thornagel, R [1 ]
Ulm, G [1 ]
机构
[1] Phys Tech Bundesanstalt, D-10587 Berlin, Germany
关键词
radiometry; detector calibration; synchrotron radiation;
D O I
10.1016/S0168-9002(99)01427-8
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The Physikalisch-Technische Bundesanstalt (PTB) currently operates a laboratory for radiometry from the VUV to the hard X-ray spectral range at the 1.7 GeV electron storage ring BESSY II. Detector calibration, performed by the PTB at BESSY I up to photon energies of about 1.5 keV, can now be extended up to 10.5 keV based on an electrical substitution radiometer as a primary detector standard and on the use of monochromatized bending magnet and undulator radiation of high spectral purity. This energetic range will be further extended up to 50 keV by using radiation from a 7 T wavelength shifter. Moreover, BESSY II is a primary source standard offering calculable bending magnet radiation. The PTB uses these primary standards for the absolute calibration of detectors with relative uncertainties below 1%. Up until now, photodiodes, energy-dispersive semiconductor detectors and also superconducting tunnel junctions have been characterized for photon energies up to 10.5 keV. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:480 / 483
页数:4
相关论文
共 50 条
  • [1] The PTB radiometry laboratory at the BESSY II electron storage ring
    Ulm, G
    Beckhoff, B
    Klein, R
    Krumrey, M
    Rabus, H
    Thornagel, R
    X-RAY OPTICS, INSTRUMENTS, AND MISSIONS, 1998, 3444 : 610 - 621
  • [2] Detector calibration at the PTB radiometry laboratory at BESSY
    Rabus, H
    Scholze, F
    Thornagel, R
    Ulm, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 377 (2-3): : 209 - 216
  • [3] Detector calibration at the PTB radiometry laboratory at BESSY
    Physikalisch-Technische, Bundesanstalt, Berlin, Germany
    Nucl Instrum Methods Phys Res Sect A, 2-3 (209-216):
  • [4] High accuracy calibration of the HXDS HPGe detector at the PTB radiometry laboratory at BESSY
    Kraft, S
    Scholze, F
    Thornagel, R
    Ulm, G
    EUX, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY VIII, 1997, 3114 : 101 - 112
  • [5] Components for the X-ray radiometry beamline at BESSY II
    Krumrey, M.
    Herrmann, C.
    Muller, P.
    Ulm, G.
    Journal of Synchrotron Radiation, 1998, 5 (03): : 788 - 790
  • [6] Components for the X-ray radiometry beamline at BESSY II
    Krumrey, M
    Herrmann, C
    Muller, P
    Ulm, G
    JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 : 788 - 790
  • [7] Characterization of silicon pore optics for the NewAthena X-ray observatory in the PTB laboratory at BESSY II
    Krumrey, M.
    Skroblin, D.
    Cibik, L.
    Collon, M.
    Vacanti, G.
    Barriere, N.
    Hauser, E.
    Bavdaz, M.
    JOURNAL OF SYNCHROTRON RADIATION, 2024, 31 : 716 - 722
  • [8] The electron storage ring BESSY II as a primary source standard from the visible to the X-ray range
    Thornagel, R
    Klein, R
    Ulm, G
    METROLOGIA, 2001, 38 (05) : 385 - 389
  • [9] X-RAY MICROSCOPY WITH SYNCHROTRON RADIATION AT THE ELECTRON STORAGE RING BESSY IN BERLIN
    NIEMANN, B
    SARAFIS, V
    RUDOLPH, D
    SCHMAHL, G
    MEYERILSE, W
    GUTTMANN, P
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 246 (1-3): : 675 - 680
  • [10] X-RAY MICROSCOPY - EXPERIMENTAL RESULTS WITH THE GOTTINGEN X-RAY MICROSCOPE AT THE ELECTRON STORAGE RING BESSY IN BERLIN
    SCHMAHL, G
    NIEMANN, B
    RUDOLPH, D
    GUTTMANN, P
    SARAFIS, V
    JOURNAL OF MICROSCOPY-OXFORD, 1985, 138 (JUN): : 279 - 284