Components for the X-ray radiometry beamline at BESSY II

被引:5
|
作者
Krumrey, M [1 ]
Herrmann, C [1 ]
Muller, P [1 ]
Ulm, G [1 ]
机构
[1] Phys Tech Bundesanstalt, D-10587 Berlin, Germany
关键词
X-ray radiometry; mirror coatings; crystal cooling;
D O I
10.1107/S0909049597014787
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Optical components for the X-ray radiometry beamline of the Physikalisch-Technische Bundesanstalt at BESSY II were investigated at BESSY I. Reflectometry measurements on different mirror coatings were used to calculate their capability to suppress higher-order radiation. An MgF2 coating proved to be best suited for photon energies below 4 keV. The reflectance of silicon (111) monochromator crystals at low photon energies around 2 keV was homogeneous within +/-1%. In a test at a superconducting wavelength shifter the cooling system for the first crystal was shown to cope with the absorbed power of 14 W.
引用
收藏
页码:788 / 790
页数:3
相关论文
共 50 条
  • [1] Components for the X-ray radiometry beamline at BESSY II
    Krumrey, M.
    Herrmann, C.
    Muller, P.
    Ulm, G.
    Journal of Synchrotron Radiation, 1998, 5 (03): : 788 - 790
  • [2] BAMline:: the first hard X-ray beamline at BESSY II
    Görner, W
    Hentschel, MP
    Müller, BR
    Riesemeier, H
    Krumrey, M
    Ulm, G
    Diete, W
    Klein, U
    Frahm, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 467 : 703 - 706
  • [3] The BESSY X-ray microfocus beamline project
    Erko, A
    Schäfers, F
    Firsov, A
    Peatman, WB
    Eberhardt, W
    Signorato, R
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2004, 59 (10-11) : 1543 - 1548
  • [4] The Russian-German soft X-ray beamline at BESSY II
    Vyalikh, DV
    Fedoseenko, SI
    Iossifov, IE
    Follath, R
    Gorovikov, SA
    Molodtsov, SL
    Schmidt, JS
    Püttner, R
    Adamchuk, VK
    Gudat, W
    Kaindl, G
    SYNCHROTRON RADIATION INSTRUMENTATION, 2004, 705 : 309 - 311
  • [5] KMC-2: the new x-ray beamline at BESSY II
    Erko, A
    Packe, I
    Hellwig, C
    Fieber-Erdmann, M
    Pawlizki, O
    Veldkamp, M
    Gudat, W
    SYNCHROTRON RADIATION INSTRUMENTATION, 2000, 521 : 415 - 418
  • [6] Comparative monochromator studies for a soft x-ray microfocus beamline for BESSY-II
    Weiss, MR
    Follath, R
    Senf, F
    Gudat, W
    JOURNAL OF ELECTRON SPECTROSCOPY AND RELATED PHENOMENA, 1999, 101 : 1003 - 1012
  • [7] X-ray microscopes at BESSY II
    Guttmann, P
    Niemann, B
    Thieme, J
    Wiesemann, U
    Rudolph, D
    Schmahl, G
    X-RAY MICROSCOPY, PROCEEDINGS, 2000, 507 : 411 - 415
  • [8] Development and present status of the Russian-German soft X-ray beamline at BESSY II
    Fedoseenko, SI
    Iossifov, IE
    Gorovikov, SA
    Schmidt, JS
    Follath, R
    Molodtsov, SL
    Adamchuk, VK
    Kaindl, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 470 (1-2): : 84 - 88
  • [9] X-ray detector calibration in the PTB radiometry laboratory at the electron storage ring BESSY II
    Beckhoff, B
    Klein, R
    Krumrey, M
    Scholze, F
    Thornagel, R
    Ulm, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 444 (1-2): : 480 - 483
  • [10] Design of a four-crystal monochromator beamline for radiometry at BESSY II
    Krumrey, Michael
    Journal of Synchrotron Radiation, 1998, 5 (01): : 6 - 9