Performance test of electron cyclotron resonance ion sources for the Hyogo Ion Beam Medical Center

被引:6
|
作者
Sawada, K [1 ]
Sawada, J
Sakata, T
Uno, K
Okanishi, K
Harada, H
Itano, A
Higashi, A
Akagi, T
Yamada, S
Noda, K
Torikoshi, M
Kitagawa, A
机构
[1] Sumitomo Heavy Ind Ltd, Niihama, Ehime 7928588, Japan
[2] Hyogo Prefectural Govt, Chuo Ku, Kobe, Hyogo 6508567, Japan
[3] Mitsubishi Elect Corp, Hyogo Ku, Kobe, Hyogo 6508555, Japan
[4] Natl Inst Radiol Sci, Inage Ku, Chiba 2638555, Japan
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2000年 / 71卷 / 02期
关键词
D O I
10.1063/1.1150367
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Two electron cyclotron resonance (ECR) ion sources were manufactured for the accelerator facility at the Hyogo Ion Beam Medical Center. H-2(+), He2+, and C4+ were chosen as the accelerating ions because they have the highest charge to mass ratio among ion states which satisfy the required intensity and quality. The sources have the same structure as the 10 GHz ECR source at the Heavy Ion Medical Accelerator in Chiba except for a few improvements in the magnetic structure. Their performance was investigated at the Sumitomo Heavy Industries factory before shipment. The maximum intensity was 1500 mu A for H-2(+), 1320 mu A for He2+, and 580 mu A for C4+ at the end of the ion source beam transport line. These are several times higher than required. Sufficient performance was also observed in the flatness and long-term stability of the pulsed beams. These test results satisfy the requirements for medical use. (C) 2000 American Institute of Physics. [S0034-6748(00)53802-7].
引用
收藏
页码:987 / 989
页数:3
相关论文
共 50 条
  • [21] Preclinical biological assessment of proton and carbon ion beams at Hyogo Ion Beam Medical Center
    Kagawa, K
    Murakami, M
    Hishikawa, Y
    Abe, M
    Akagi, T
    Yanou, T
    Kagiya, G
    Furusawa, Y
    Ando, K
    Nojima, K
    Aoki, M
    Kanai, T
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 54 (03): : 928 - 938
  • [22] The influence of ambipolarity on plasma confinement and on the performance of electron cyclotron resonance ion sources
    Schachter, L.
    Dobrescu, S.
    Stiebing, K. E.
    Thuillier, T.
    Lamy, T.
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2008, 79 (02):
  • [23] Electron cyclotron resonance plasmas and electron cyclotron resonance ion sources: Physics and technology (invited)
    Girard, A
    Hitz, D
    Melin, G
    Serebrennikov, K
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (05): : 1381 - 1388
  • [24] Simulation of ion extraction and acceleration from electron cyclotron resonance ion sources
    Khodja, H
    Brenac, A
    Girard, A
    Lamboley, G
    [J]. ICPP 96 CONTRIBUTED PAPERS - PROCEEDINGS OF THE 1996 INTERNATIONAL CONFERENCE ON PLASMA PHYSICS, VOLS 1 AND 2, 1997, : 458 - 461
  • [25] Electron Cyclotron Resonance Ion Sources for Highly-Charged Ion Beams
    Koivisto, H.
    [J]. APPLICATION OF ACCELERATORS IN RESEARCH AND INDUSTRY, 2009, 1099 : 25 - 30
  • [26] Ridge filter design for proton therapy at Hyogo Ion Beam Medical Center
    Akagi, T
    Higashi, A
    Tsugami, H
    Sakamoto, H
    Masuda, Y
    Hishikawa, Y
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (22): : N301 - N312
  • [27] Beam experiments with the Grenoble test electron cyclotron resonance ion source at iThemba LABS
    Thomae, R.
    Conradie, J.
    Fourie, D.
    Mira, J.
    Nemulodi, F.
    Kuechler, D.
    Toivanen, V.
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (02):
  • [28] The physics of ion beam extraction from an electron cyclotron resonance ion source
    Spaedtke, Peter
    [J]. IEEE TRANSACTIONS ON PLASMA SCIENCE, 2008, 36 (04) : 1569 - 1573
  • [29] Current State Of Proton And Carbon-Ion Radiotherapy At The Hyogo Ion Beam Medical Center (HIBMC)
    Murakami, Masao
    Demizu, Yusuke
    Niwa, Yasue
    Fujii, Osamu
    Terashima, Kazuki
    Mima, Masayuki
    Miyawaki, Daisuke
    Sasaki, Ryohei
    Hishikawa, Yoshio
    Abe, Mitsuyuki
    [J]. APPLICATION OF ACCELERATORS IN RESEARCH AND INDUSTRY: TWENTY-FIRST INTERNATIONAL CONFERENCE, 2011, 1336 : 374 - 376
  • [30] Lost electron energy distribution of electron cyclotron resonance ion sources
    Izotov, I.
    Skalyga, V.
    Tarvainen, O.
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2022, 93 (04):