Fluence determination by scattering measurements

被引:1
|
作者
Albergo, S
Boemi, D
Potenza, R
Tricomi, A
Pillon, M
Angarano, M
Creanza, D
De Palma, M
机构
[1] Catania Univ, Ist Nazl Fis Nucl, Dipartimento Fis, Sez Catania, I-95129 Catania, Italy
[2] EURATOM Assoc, ENEA Fus, I-00044 Frascati, Italy
[3] Univ Bari, Dipartimento Fis, Bari, Italy
[4] Ist Nazl Fis Nucl, Sez Bari, I-70126 Bari, Italy
关键词
fluence silicon radiation damage;
D O I
10.1016/S0168-9002(99)00879-7
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
An alternative method to determine particle fluence is proposed, which is particularly suitable for irradiations with low-energy charged-particle beams. The fluence is obtained by measuring the elastic scattering produced by a composite thin target placed upstream of the sample. The absolute calibration is performed by comparison with the measured radioactivation of vanadium and copper samples. The composite thin target, made of aluminium, carbon and gold, allows not only the fluence to be measured, but also a continuous monitoring of the beam space distribution. Experimental results with a 27 MeV proton beam are reported and compared with Monte Carlo simulations. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:8 / 14
页数:7
相关论文
共 50 条
  • [21] DETERMINATION OF CHAIN STATISTICAL PARAMETERS BY LIGHT-SCATTERING MEASUREMENTS
    MAZUR, J
    MCINTYRE, D
    MACROMOLECULES, 1975, 8 (04) : 464 - 476
  • [22] SETUP FOR THE DETERMINATION OF THE PHOTODYNAMIC ACTIVITY OF DYES ON THE BASIS OF SCATTERING MEASUREMENTS
    KONIG, K
    AUCHTER, S
    BIOMEDIZINISCHE TECHNIK, 1991, 36 (09): : 201 - 205
  • [23] Determination of spatial laser radiation parameters by Rayleigh scattering measurements
    Solov'ev, A.P.
    Zyuryukina, O.V.
    Pribory i Tekhnika Eksperimenta, 1999, 42 (03): : 405 - 408
  • [25] Neutron Fluence in Antiproton Radiotherapy, Measurements and Simulations
    Bassler, Niels
    Holzscheiter, Michael H.
    Petersen, Jorgen B.
    ACTA ONCOLOGICA, 2010, 49 (07) : 1149 - 1159
  • [26] Neutron fluence and dose measurements by optical fibres
    Henschel, H
    Kohn, O
    Metzger, S
    Decreton, M
    Devos, P
    Deparis, O
    Kirchhof, J
    Grimm, S
    NEUTRONS IN RESEARCH AND INDUSTRY, INTERNATIONAL CONFERENCE, 1997, 2867 : 290 - 295
  • [27] Fluence and dose measurements for an accelerator neutron beam
    Liu, Z.
    Lyun, S. H.
    McNeill, F. E.
    Mothersill, C. E.
    Seymour, C. B.
    Prestwich, W. V.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2007, 263 (01): : 326 - 328
  • [28] Fluence and dosimetric measurements for a pi(+/-) irradiation facility
    Furetta, C
    Bates, SJ
    Glaser, M
    Lemeilleur, F
    Tavlet, M
    LeonFlorian, E
    Leroy, C
    NUCLEAR PHYSICS B, 1995, : 503 - 509
  • [29] Fluence uncertainties of laser damage threshold measurements
    Hu, Jianping
    Wang, Jian
    Xin, Zhou
    Chen, Songlin
    Ping, Ma
    Qiao, Xu
    LASER PHYSICS, 2014, 24 (01)
  • [30] THE DETERMINATION OF FLUENCE TO DOSE EQUIVALENT CONVERSION FACTORS FOR AMERICIUM-BERYLLIUM AND CALIFORNIUM SOURCES FROM MICRODOSIMETRIC MEASUREMENTS
    STARK, MS
    WAKER, AJ
    HUNT, JB
    RADIATION PROTECTION DOSIMETRY, 1987, 18 (03) : 141 - 146