Quantification of ultra-trace organolead species in environmental water by inductively coupled plasma mass spectrometry with online solid-phase extraction and high performance liquid chromatographic separation

被引:17
|
作者
Yang, Shiwei [1 ]
Song, Yihuan [1 ]
Ma, Qingfang [3 ]
Cheng, Heyong [1 ,3 ]
Wang, Yuanchao [1 ]
Liu, Jinhua [2 ,3 ]
机构
[1] Hangzhou Normal Univ, Coll Mat Chem & Chem Engn, Hangzhou 311121, Peoples R China
[2] Hangzhou Normal Univ, Qianjiang Coll, Hangzhou 310036, Peoples R China
[3] Hangzhou Normal Univ, Key Lab Organosilicon Chem & Mat Technol, Hangzhou 311121, Peoples R China
基金
中国国家自然科学基金;
关键词
Lead speciation; Solid phase extraction; Graphene oxide; Online enrichment; HPLC-ICP-MS; Water; ATOMIC-ABSORPTION-SPECTROMETRY; SPECIATION ANALYSIS; LEAD SPECIATION; ISOTOPE-DILUTION; GRAPHENE; PRECONCENTRATION; MERCURY; SORBENT; SAMPLES; PB(II);
D O I
10.1016/j.aca.2020.07.046
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Quantification of organolead compounds in environmental water is an essential task considering much higher toxicity and bioavailability of organolead species than inorganic plumbic ions. However, the speciation of ultra-trace organolead compounds at sub ng L-1 levels is challengeable for current instruments incorporating high performance liquid chromatography with inductively coupled plasma mass spectrometry (HPLC-ICP-MS) and even offline enrichment that offer detection limits around several to tens of ng L-1. In this paper, an online solid-phase extraction (SPE) coupled HPLC-ICP-MS method was developed for speciation analysis of trace lead in water. Graphene oxide bounded silica particles (GO@SiO2) was utilized as the SPE adsorbent because of its superior performance over graphene bounded silica particles and commercial C18 packing particles. High enrichment factors (1603 for TML and 1376 for TEL) were obtained when lead species in 10 mL sample was adsorbed by 1 mM sodium dodecyl benzene sulfonate (SDBS) preconditioned GO@SiO2 at 10 mL min(-1) and then eluted by 5 mu L of 5 mM SDBS. Because of the highly efficient preconcentration, detection limits were downscaled to be 0.018 for TML and 0.023 ng L-1 for TEL with relative standard deviations below 5%. Additionally, the proposed method also yielded rapid separation of Pb(II), TML and TEL (8 min) by using green mobile phases (aqueous solutions of 5 mM sodium 1-pentanesulfonate at pH 2.5 with/without 4 mM tetrabutylammounium hydroxide). Upon successful application to fresh water, TML and TEL were only presented in the river water whereas Pb(II) was only existed in the tap water, along with accuracy validation by good spiked recoveries (93-106%). (C) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页码:30 / 38
页数:9
相关论文
共 50 条
  • [21] Solid-phase extraction in combination with dispersive liquid-liquid microextraction and ultra-high performance liquid chromatography-tandem mass spectrometry analysis: the ultra-trace determination of 10 antibiotics in water samples
    Liang, Ning
    Huang, Peiting
    Hou, Xiaohong
    Li, Zhen
    Tao, Lei
    Zhao, Longshan
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2016, 408 (06) : 1701 - 1713
  • [22] Quantification of plasma carnitine and acylcarnitines by high-performance liquid chromatography-tandem mass spectrometry using online solid-phase extraction
    Réjane Morand
    Massimiliano Donzelli
    Manuel Haschke
    Stephan Krähenbühl
    Analytical and Bioanalytical Chemistry, 2013, 405 : 8829 - 8836
  • [23] Solid-phase extraction in combination with dispersive liquid-liquid microextraction and ultra-high performance liquid chromatography-tandem mass spectrometry analysis: the ultra-trace determination of 10 antibiotics in water samples
    Ning Liang
    Peiting Huang
    Xiaohong Hou
    Zhen Li
    Lei Tao
    Longshan Zhao
    Analytical and Bioanalytical Chemistry, 2016, 408 : 1701 - 1713
  • [24] Ultra-trace determination of gold nanoparticles in environmental water by surfactant assisted dispersive liquid liquid microextraction coupled with electrothermal vaporization-inductively coupled plasma-mass spectrometry
    Liu, Ying
    He, Man
    Chen, Beibei
    Hu, Bin
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2016, 122 : 94 - 102
  • [25] Simplified cloud point extraction-inductively coupled plasma mass spectrometry for the preconcentration/analysis of ultra-trace gold
    Chen, Songqing
    Zhu, Xiashi
    MINERALS ENGINEERING, 2010, 23 (14) : 1152 - 1154
  • [26] A dipole-assisted solid-phase extraction microchip combined with inductively coupled plasma-mass spectrometry for online determination of trace heavy metals in natural water
    Shih, Tsung-Ting
    Hsu, I-Hsiang
    Chen, Shun-Niang
    Chen, Ping-Hung
    Deng, Ming-Jay
    Chen, Yu
    Lin, Yang-Wei
    Sun, Yuh-Chang
    ANALYST, 2015, 140 (02) : 600 - 608
  • [27] Solid-phase extraction coupled with high performance liquid chromatography-tandem mass spectrometry
    Huang, Jin-Feng
    Xian, Yan-Ping
    Li, Xiu-Ying
    Cai, Wei-Hong
    Li, He
    Lin, Sen-Yu
    He, Min-Heng
    Guo, Xin-Dong
    Modern Food Science and Technology, 2014, 30 (12) : 241 - 246
  • [28] Arsenic Species Analysis at Trace Level by High Performance Liquid Chromatography with Inductively Coupled Plasma Mass Spectrometry
    Hou, Hongfang
    Cui, Wanjing
    Xu, Qing
    Tao, Zhanhui
    Guo, Yafei
    Deng, Tianlong
    INTERNATIONAL JOURNAL OF ANALYTICAL CHEMISTRY, 2019, 2019
  • [29] Online Solid-Phase Extraction-Inductively Coupled Plasma- Quadrupole Mass Spectrometry with Oxygen Dynamic Reaction for Quantification of Technetium-99
    Matsueda, Makoto
    Yanagisawa, Kayo
    Koarai, Kazuma
    Terashima, Motoki
    Fujiwara, Kenso
    Abe, Hironobu
    Kitamura, Akihiro
    Takagai, Yoshitaka
    ACS OMEGA, 2021, 6 (29): : 19281 - 19290
  • [30] Eggshell Membrane Microcolumn Solid-Phase Extraction and Determination of Trace Gold in Geological Samples by Inductively Coupled Plasma Mass Spectrometry
    Cheng, Xianzhong
    Liu, Jin
    Yang, Xiaoli
    Chen, Hongmei
    Wang, Yourong
    ATOMIC SPECTROSCOPY, 2011, 32 (05) : 175 - 181