Impact of lung density on isolated lung tumor dose in VMAT using inline MR-Linac

被引:0
|
作者
Ohno, Takeshi [1 ]
Araki, Fujio [1 ]
Anami, Naoki [2 ]
Kubota, Takahiro [2 ,3 ]
Yano, Masayuki [4 ]
Ito, Shotaro [5 ]
机构
[1] Kumamoto Univ, Fac Life Sci, Dept Hlth Sci, 4-24-1 Kuhonji, Kumamoto, Japan
[2] Kumamoto Univ, Grad Sch Hlth Sci, 4-24-1 Kuhonji, Kumamoto, Japan
[3] Kokura Mem Hosp, 3-2-1 Asano, Kokura, Fukuoka, Japan
[4] Saga Heavy Ion Med Accelerator Tosu, 3049 Koga Machi, Tosu, Saga, Japan
[5] Natl Hosp Org Kyushu Med Ctr, 1-8-1 Jigyouhama, Fukuoka, Japan
关键词
MR-Linac; Isolated lung tumor; Lung density; Monte Carlo method; MAGNETIC-FIELDS; RADIOTHERAPY; DISTRIBUTIONS; VERIFICATION; ENHANCEMENT; DOSIMETRY; ELECTRON; BEAM;
D O I
10.1016/j.ejmp.2020.10.009
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This study investigated the impact of lung density on the isolated lung tumor dose for volumetric modulated arc therapy (VMAT) in an inline magnetic resonance linear accelerator (MR-Linac) using the Monte Carlo (MC) simulation. Methods: CT images of the thorax phantoms with lung tumors of 1, 2, and 3 cm diameters were converted into voxel-base phantoms with lung densities of 0.1, 0.2, and 0.3 g/cm(3), respectively. The dose distributions were calculated for partial-arc VMAT. The dose distributions were compared using dose differences, dose volume histograms, and dose volume indices. Results: In all cases, the inline magnetic field significantly enhanced the lung tumor dose compared to that at 0 T. For the 1 cm lung tumor, the inline magnetic field of 1 T increased the minimum dose of 95% of the Planning target volume (PTV D-95) by 14.0% in 0.1 g/cm(3) ling density as compared to that in 0.3 g/cm(3) at 0 T. In contrast, at 0 and 0.5 T, the PTV D-95 in 0.3 g/cm(3) lung density was larger than that in lung density of 0.1 g/cm(3). For the 2 cm lung tumor, a similar tendency to 1 cm was observed, whereas the dose impact of lung density was smaller than that for 1 cm. For the 3 cm lung tumor, the lung tumor dose was independent of lung density at 0.5 T and 1.0 T. Conclusion: The inline MR-Linac with the magnetic field over 1 T can enhance the PTV D-95 for VMAT regardless of the lung density.
引用
收藏
页码:65 / 74
页数:10
相关论文
共 50 条
  • [41] Using a Commercial Convolution/Superposition Dose Engine for MR-LINAC On-line Plan QA
    Li, Y.
    Wang, B.
    Ding, S.
    Liu, H.
    Liu, B.
    Qi, X.
    Xia, Y. F.
    Huang, X.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : E282 - E282
  • [42] Using a Commercial Convolution/Superposition Dose Engine for MR-LINAC On-Line Plan QA
    Li, Y.
    Song, T.
    Wang, B.
    Ding, S.
    Liu, H.
    Xia, Y.
    Huang, X.
    MEDICAL PHYSICS, 2020, 47 (06) : E873 - E873
  • [43] Improved lung tumor autocontouring algorithm for intrafractional tumor tracking using 0.5 T linac-MR
    Yun, Jihyun
    Yip, Eugene
    Gabos, Zsolt
    Wachowicz, Keith
    Rathee, Satyapal
    Fallone, B. G.
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2016, 2 (06):
  • [44] Automatic PTV margin determination for midposition-based lung SBRT planning on the Unity MR-linac
    Ligtenberg, H.
    Hackett, S.
    Merckel, L. G.
    Snoeren, L.
    Kontaxis, C.
    Zachiu, C.
    Bol, G.
    Verhoeff, J. J.
    Fast, M. F.
    RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S697 - S698
  • [45] Potential Dose Escalation for Pancreas SBRT Patients as a Result of Simulated Tumor Tracking and Margin Reduction in a MR-Linac
    Al-Ward, S.
    Ruschin, M.
    Kim, A.
    Chu, W.
    Myrehaug, S.
    Sahgal, A.
    Keller, B.
    MEDICAL PHYSICS, 2018, 45 (06) : E551 - E552
  • [46] MRI-based ventilation and perfusion imaging to predict radiation-induced pneumonitis in lung tumor patients at a 0.35 T MR-Linac
    Klaar, Rabea
    Rabe, Moritz
    Stueber, Anna Theresa
    Hering, Svenja
    Corradini, Stefanie
    Eze, Chukwuka
    Marschner, Sebastian
    Belka, Claus
    Landry, Guillaume
    Dinkel, Julien
    Kurz, Christopher
    RADIOTHERAPY AND ONCOLOGY, 2024, 199
  • [47] Correcting dose distributions to the magnetic field of a high-field MR-Linac using deep learning
    Rozendaal, R.
    Van den Wollenberg, W.
    Van Kranen, S.
    Sonke, J.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S969 - S970
  • [48] Dose escalation with integrated boost using high-field MR-LINAC in prostate cancer patients
    Onal, C.
    Arslan, G.
    Yavas, C.
    Efe, E.
    Yavas, G.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S1594 - S1595
  • [49] MLC tracking and dose accumulation validation on the MR-linac using a real-time deformable dosimeter
    van den Dobbelsteen, Madelon
    Borman, Pim T. S.
    de Vries, Laurie J. M.
    Hackett, Sara L.
    Penev, Kalin
    Flores, Rocco
    Smith, Stephanie
    LeChasseur, Yoan
    Lambert-Girard, Simon
    Cote, Benjamin
    Woodhead, Peter L.
    Bosma, Lando S.
    Zachiu, Cornel
    Raaymakers, Bas W.
    Fast, Martin F.
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S4272 - S4276
  • [50] Measurement of surface dose in a 1.5 T MR-Linac using plane-parallel ionization chamber
    Yang, B.
    Lam, W. W.
    Tang, K. K.
    Law, W. K.
    Cheung, K. Y.
    Yu, S. K.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S711 - S711